Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-10T17:39:57.096Z Has data issue: false hasContentIssue false

Combined multiple-excitation FP method for micro-XRF analysis of difficult samples

Published online by Cambridge University Press:  29 February 2012

W. T. Elam*
Affiliation:
EDAX, Ametek, Inc., Mahwah, New Jersey 07430
Bruce Scruggs
Affiliation:
EDAX, Ametek, Inc., Mahwah, New Jersey 07430
Joseph Nicolosi
Affiliation:
EDAX, Ametek, Inc., Mahwah, New Jersey 07430
*
a)Author to whom correspondence should be addressed. Electronic mail: tim.elam@ametek.com

Abstract

Accurate minor and trace element analysis via micro-XRF can be more difficult to accomplish in single crystal and polycrystalline materials due to diffraction phenomena which obscure elemental peaks and distort the spectral background. A primary-beam filter is commonly used to eliminate diffractive artifacts as well as tube characteristic lines, but this dramatically reduces the sensitivity to lighter elements. One way around this is to collect a spectrum with unfiltered excitation to obtain the low-energy region, i.e., Na, Mg, Al, and Si, and then collect other portions of the spectrum under more optimized conditions. The fundamental parameter method is capable of using multiple spectra to quantify the complete element suite of the sample. By unifying the quantification for several spectra taken under different excitation conditions, the overall results can be improved. We have applied this method to selected cases for geological and metallurgical samples. The combined method gives better results for all elements than the single spectrum quantification as judged by agreement with the values from the supplier.

Type
Technical Articles
Copyright
Copyright © Cambridge University Press 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Elam, W. T., Shen, R. B., Scruggs, B., and Nicolosi, J. (2004). “Accuracy of standardless FP analysis of bulk and thin film samples using a new atomic database,” Adv. X-Ray Anal. AXRAAA 47, 104109.Google Scholar
Scruggs, B., Haschke, M., Herczeg, L., and Nicolosi, J. (2000). “XRF mapping: New tools for distribution analysis,” Adv. X-Ray Anal. AXRAAA 42, 1925.Google Scholar
Sutton, S. R., Rivers, M. L., and Smith, J. V. (1986). “Synchrotron X-ray fluorescence: Diffraction interference,” Anal. Chem. ANCHAM 58, 21672171.10.1021/ac00124a013CrossRefGoogle Scholar
Tissot, R. G. and Goehner, R. P. (1992). “Diffraction peaks in x-ray spectroscopy: Friend or foe?,” Adv. X-Ray Anal. AXRAAA 36, 8996.Google Scholar
Verkhovodov, P. K. (2005). “Effect of crystal structure on the background intensity in XRF,” X-Ray Spectrom. XRSPAX 34, 169171.10.1002/xrs.780CrossRefGoogle Scholar