Hostname: page-component-78c5997874-dh8gc Total loading time: 0 Render date: 2024-11-11T15:06:10.192Z Has data issue: false hasContentIssue false

Potential Exposure to Ebola Virus from Body Fluids due to Ambulance Compartment Permeability in Sierra Leone

Published online by Cambridge University Press:  28 October 2015

Megan L. Casey*
Affiliation:
Epidemic Intelligence Service, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA Sierra Leone Ebola Response Team, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA Division of Respiratory Disease Studies, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA
Duong T. Nguyen
Affiliation:
Epidemic Intelligence Service, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA Sierra Leone Ebola Response Team, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA
Barrie Idriss
Affiliation:
Bombali District Health Management Team, Sierra Leone Ministry of Health and Sanitation, Makeni, Bombali, Sierra Leone
Sarah Bennett
Affiliation:
Sierra Leone Ebola Response Team, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA Division of Foodborne, Waterborne, and Environmental Diseases, National Center for Emerging & Zoonotic Infectious Diseases, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA
Angela Dunn
Affiliation:
Epidemic Intelligence Service, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA Sierra Leone Ebola Response Team, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA
Stephen Martin
Affiliation:
Division of Respiratory Disease Studies, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia USA
*
Correspondence: Megan Casey, RN, BSN, MPH Epidemic Intelligence Service Officer National Institute for Occupational Safety and Health Division of Respiratory Disease Studies Surveillance Branch Mailstop HG900 1095 Willowdale Road Morgantown, West Virginia 26505 USA E-mail: ydg7@cdc.gov

Abstract

Introduction

Prehospital care, including patient transport, is integral in the patient care process during the Ebola response. Transporting ill persons from the community to Ebola care facilities can stop community spread. Vehicles used for patient transport in infectious disease outbreaks should be evaluated for adequate infection prevention and control.

Problem

An ambulance driver in Sierra Leone attributed his Ebola infection to exposure to body fluids that leaked from the patient compartment to the driver cabin of the ambulance.

Methods

A convenience sample of 14 vehicles used to transport patients with suspected or confirmed Ebola in Sierra Leone were assessed. The walls separating the patient compartment and driver cabin in these vehicles were evaluated for structural integrity and potential pathways for body fluid leakage. Ambulance drivers and other staff were asked to describe their cleaning and decontamination practices. Ambulance construction and design standards from the National Fire Protection Association, US General Services Administration, and European Committee on Standardization (CEN) were reviewed.

Results

Many vehicles used by ambulance staff in Sierra Leone were not traditional ambulances, but were pick-up trucks or sport-utility vehicles that had been assembled or modified for patient transport. The wall separating the patient compartment and driver cabin in many vehicles did not have a waterproof seal around the edges. Staff responsible for cleaning and disinfection did not thoroughly clean bulk body fluids with disposable towels before disinfection of the patient compartment. Pressure from chlorine sprayers used in the decontamination process may have pushed body fluids from the patient compartment into the driver cabin through gaps around the wall. Ambulance design standards do not require a waterproof seal between the patient compartment and driver cabin. Sealing the wall by tightening or replacing existing bolts is recommended, followed by caulking of all seams with a sealant.

Conclusion

Waterproof separation between the patient compartment and driver cabin may be essential for patient transport vehicles in infectious disease outbreaks, especially when chlorine sprayers are used for decontamination or in resource-limited settings where cleaning supplies may be limited.

CaseyML , NguyenDT , IdrissB , BennettS , DunnA , MartinS . Potential Exposure to Ebola Virus from Body Fluids due to Ambulance Compartment Permeability in Sierra Leone. Prehosp Disaster Med. 2015;30(6):625–627.

Type
Case Reports
Copyright
© World Association for Disaster and Emergency Medicine 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. World Health Organization. Ebola Situation Report. http://apps.who.int/ebola/current-situation/ebola-situation-report-23-september-2015. Accessed September 28, 2015.Google Scholar
2. Kilmarx, PH, Clarke, KR, Dietz, PM, et al. Ebola virus disease in health care workers - Sierra Leone, 2014. MMWR Morb Mortal Wkly Rep. 2014;63(49):1168-1171.Google Scholar
3. Sikka, N, Margolis, G. Understanding diversity among prehospital care delivery systems around the world. Emerg Med Clin N Am. 2005;23(1):99-114.CrossRefGoogle ScholarPubMed
4. Centers for Disease Control and Prevention. Interim Guidance for Ambulance Service Providers in West Africa Ebola-Affected Areas. http://www.cdc.gov/vhf/ebola/hcp/guidance-ambulance-service-providers.html. Accessed June 3, 2015.Google Scholar
5. US General Services Administration (GSA). KKK-A-1822F, Federal Specification for the Star-of-Life Ambulance. Arlington, Virginia USA: General Services Administration, Office of Motor Vehicle Management; August 2008.Google Scholar
6. National Fire Protection Association (NFPA). NFPA 1917:2013, Standard for Automotive Ambulances. Quincy, Massachusetts USA: National Fire Protection Association; August 2012.Google Scholar
7. European Committee for Standardization (CEN). CEN 1789:2007, Medical Vehicles and their Equipment - Road Ambulances. Brussels, Belgium: European Committee for Standardization, Management Centre; June 2007.Google Scholar