Hostname: page-component-78c5997874-ndw9j Total loading time: 0 Render date: 2024-11-13T04:16:17.294Z Has data issue: false hasContentIssue false

Comparison of Determined Stellar Parameters between LAMOST and SEGUE Spectra

Published online by Cambridge University Press:  06 January 2014

Yue Wu
Affiliation:
National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, 100012, Beijing, China(NAOC) email: wuyue@lamost.org Key Laboratory of Optical Astronomy, NAOC, Chinese Academy of Sciences, China
Ali Luo
Affiliation:
National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, 100012, Beijing, China(NAOC) email: wuyue@lamost.org Key Laboratory of Optical Astronomy, NAOC, Chinese Academy of Sciences, China
Bing Du
Affiliation:
National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, 100012, Beijing, China(NAOC) email: wuyue@lamost.org Key Laboratory of Optical Astronomy, NAOC, Chinese Academy of Sciences, China
Yanxin Guo
Affiliation:
National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, 100012, Beijing, China(NAOC) email: wuyue@lamost.org Key Laboratory of Optical Astronomy, NAOC, Chinese Academy of Sciences, China
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

We positionally cross-matched the stellar observations between LAMOST pilot survey and SDSS/SEGUE database, picked out more than 4000 targets observed by both projects, mostly are late A and FGK type stars. For the two dataset, we adopted ULySS program (Koleva et al. 2009, Wu et al. 2011a) to determine the stellar atmospheric parameters (Teff, log g, [Fe/H], Radial Velocity) with the ELODIE library as a reference (Wu et al. 2011b). For the individual parameter, we made two kinds of comparison, first for the SDSS spectra, second for the LAMOST spectra, tested the differences between the SSPP (SDSS/SEGUE stellar parameter pipeline) measurements and the ULySS derived results. Since the LAMOST pilot survey observations SNR (Signal to Noise Ratio) are low, for the latter comparison we excluded those stars with g band SNR < 10, then the sample volumn reduced to around 1300. Fig.1 displays the details of the second kind comparison for each parameter. All the comparisons demonstrate acceptable and reasonable agreement between each other for medium-resolution survey spectra. Our preliminary examination on the precision of the stellar parameters that could be derived from the LAMOST pilot survey observations exhibits the equivalent capability of LAMOST to study our Milky Way as for the SDSS/SEGUE. The LAMOST telescope executed its formal survey from Sep. 28th 2012, it will yield more better quality stellar spectroscopic data spanning in deeper and broader sky coverage (this work was supported by the Natural Science Foundation of China under No. 11103031).

Type
Contributed Papers
Copyright
Copyright © International Astronomical Union 2014 

References

Koleva, M., Prugniel, P., Bouchard, A., & Wu, Y. 2009, A&A, 501, 1269Google Scholar
Wu, Y., Luo, Ali, Li, H. N., et al. 2011a, RAA, 11, 924Google Scholar
Wu, Y., Singh, H. P., Prugniel, P., et al. 2011b, A&A, 525, 71Google Scholar