Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-27T08:17:37.339Z Has data issue: false hasContentIssue false

K-shell transitions in L-shell ions with the EBIT calorimeter spectrometer

Published online by Cambridge University Press:  27 October 2016

Natalie Hell
Affiliation:
Dr. Remeis-Sternwarte & ECAP, Friedrich-Alexander Universität Erlangen-Nürnberg, Sternwartstr. 7, 96049 Bamberg, Germany email natalie.hell@sternwarte.uni-erlangen.de Lawrence Livermore National Laboratory, 7000 East Ave., Livermore
Greg V. Brown
Affiliation:
Lawrence Livermore National Laboratory, 7000 East Ave., Livermore
Jörn Wilms
Affiliation:
Dr. Remeis-Sternwarte & ECAP, Friedrich-Alexander Universität Erlangen-Nürnberg, Sternwartstr. 7, 96049 Bamberg, Germany email natalie.hell@sternwarte.uni-erlangen.de
Peter Beiersdorfer
Affiliation:
Lawrence Livermore National Laboratory, 7000 East Ave., Livermore
Richard L. Kelley
Affiliation:
NASA-GSFC, 8800 Greenbelt Road, Greenbelt, MD 20771, USA
Caroline A. Kilbourne
Affiliation:
NASA-GSFC, 8800 Greenbelt Road, Greenbelt, MD 20771, USA
F. Scott Porter
Affiliation:
NASA-GSFC, 8800 Greenbelt Road, Greenbelt, MD 20771, USA
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

With the large improvement in effective area of Astro-H's micro-calorimeter soft X-ray spectrometer (SXS) over grating spectrometers, high-resolution X-ray spectroscopy with good signal to noise will become more commonly available, also for faint and extended sources. This will result in a range of spectral lines being resolved for the first time in celestial sources, especially in the Fe region. However, a large number of X-ray line energies in the atomic databases are known to a lesser accuracy than that expected for Astro-H/SXS, or have no known uncertainty at all. To benchmark the available calculations, we have therefore started to measure reference energies of K-shell transition in L-shell ions for astrophysically relevant elements in the range 11≤ Z ≤ 28 (Na to Ni), using the Lawrence Livermore National Laboratory's EBIT-I electron beam ion trap coupled with the NASA/GSFC EBIT calorimeter spectrometer (ECS). The ECS has a resolution of ~5 e V, i.e., similar to Astro-H/SXS and Chandra/HETG. A comparison to crystal spectra of lower charge states of sulfur with ~0.6 e V resolution shows that the analysis of spectra taken at ECS resolution allows to determine the transition energies of the strongest components.

Type
Contributed Papers
Copyright
Copyright © International Astronomical Union 2016 

References

Hell, N., Miškovičová, I., Brown, G. V., et al. 2013, Phys. Scr., T156, 014008 CrossRefGoogle Scholar
Hughes, J. P., Safi-Harb, S., Bamba, A., et al. 2014, arxiv:1412.1169v1Google Scholar
Marrs, R. E., Levine, M. A., Knapp, D. A., & Henderson, J. R. 1988, Phys. Rev. Lett., 60, 1715 CrossRefGoogle Scholar
Porter, F. S., Beiersdorfer, P., Brown, G. V., et al. 2008, J. Low Temp. Phys., 151, 1061 CrossRefGoogle Scholar
Takahashi, T., Mitsuda, K., Kelley, R., et al. 2010, in: Arnaud, M., Murray, S. S., Takahashi, T. (eds.), Space Telescopes and Instrumentation 2010: UV to Gamma Ray, Proc. SPIE 7732 Google Scholar
Yamaguchi, H., Eriksen, K. A., Badenes, C., et al., 2014, ApJ 780, 136 CrossRefGoogle Scholar