Hostname: page-component-cd9895bd7-7cvxr Total loading time: 0 Render date: 2024-12-25T17:00:12.840Z Has data issue: false hasContentIssue false

The pitfalls of dose titration as used in electroconvulsive therapy

Published online by Cambridge University Press:  02 January 2018

P. O. Byrne
Affiliation:
Regional Medical Physics Department
R. G. Farquharson
Affiliation:
Newcastle General Hospital, Newcastle Upon Tyne NE4 6BE
I. S. Schofield
Affiliation:
Newcastle General Hospital, Newcastle Upon Tyne NE4 6BE
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Dose titration is the new colloquialism in ECT circles. The technique, as generally applied, assumes that current and the time for which it is passed, are equally important in the depolarisation of nerve cells. The units used to quantify its measurement, namely the milliCoulomb (mC) reflect this. We think this is misleading and suggest it ought not to be used as a parameter to describe a treatment regime. It is the aim of this communication to explain, in general terms, the physical parameters that control the current flowing in the patient's head, to suggest a more appropriate method to describe the treatment administered and outline the requirements of a good ECT machine.

Type
Original Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
Copyright © Royal College of Psychiatrists, 1995

References

Abrams, R. (1992) Electroconvulsive Therapy. New York: Oxford University Press.Google ScholarPubMed
Offner, F. (1942) Electrical properties of tissues in shock therapy. Proceedings of the Society of Experimental Biology and Medicine, 49, 571574.Google Scholar
Sackeim, H. A., Devanand, D. P. & Prudic, J. (1991) Stimulus intensity, seizure threshold, and seizure duration. Psychiatric Clinics of North America, 14, 803843.Google Scholar
Sackeim, H. A., Devanand, D. P. Decina, P., Prohovnik, I. & Malitz, S. (1987) Seizure threshold in electroconvulsive therapy. Archives of General Psychiatry. 44, 355360.Google Scholar
Weaver, L., Williams, R., & Rush, S. (1976) Current density in bilateral and unilateral ECT. Biological Psychiatry, 11, 303312.Google Scholar