Hostname: page-component-cd9895bd7-mkpzs Total loading time: 0 Render date: 2024-12-27T12:42:01.409Z Has data issue: false hasContentIssue false

Evaluation of a bar-code system for nutrient analysis in dietary surveys

Published online by Cambridge University Press:  02 January 2007

Annie S Anderson*
Affiliation:
Centre for Applied Nutrition Research, University of Dundee, Dundee DD1 4HT, UK
Linda Maher
Affiliation:
Department of Human Nutrition, University of Glasgow, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
Tom K Ha
Affiliation:
Department of Human Nutrition, University of Glasgow, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
Josephine Cooney
Affiliation:
Institute of Biochemistry, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
Susan Eley
Affiliation:
Department of Human Nutrition, University of Glasgow, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
Marilyn Martin
Affiliation:
Department of Human Nutrition, University of Glasgow, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
Giacomo Vespasiani
Affiliation:
Medimatica, San Benedetto del Tronto, Italy
Mauro Bruni
Affiliation:
Medimatica, San Benedetto del Tronto, Italy
Michael EJ Lean
Affiliation:
Department of Human Nutrition, University of Glasgow, Glasgow Royal Infirmary, Glasgow G31 2ER, UK
*
*Corresponding author: Email: a.s.anderson@dundee.ac.uk
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
Objective:

A novel system for nutrient analysis has been developed and tested over 5 years. Its key features are a nutrient database of 600 commonly eaten foods (95% of foods eaten in 7-day surveys); a booklet identifying each food with a bar code, bar codes for gram weight and for portion sizes (small, medium, large) and a bar-code reader with dietary analysis software for PCs. In the present study the bar-code system has been evaluated by comparison with a commonly used manual entry nutrient analysis software for dietitians' use.

Design:

Cross-sectional.

Setting:

Glasgow city district.

Subjects:

One hundred and sixty adults aged 18–65 years old.

Results:

Comparing mean intakes for macro- and micronutrients, using the Bland and Altman method1, the bias between the two methods was small, ranging from 0.93 to 1.03. The bar-code system took significantly less professional time in data entry and nutrient analysis than the widely used manual system (29 min per 7-day diary vs. 47 min per 7-day diary, P < 0.001).

Conclusions:

It is suggested that the bar-code system offers greater speed with a saving of professional time needed for nutrient analysis of dietary surveys. This system is commended for maintaining accuracy while promoting economy.

Type
Research Article
Copyright
Copyright © CABI Publishing 1999

References

1: Bland, JM, Altman, DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307–10.Google Scholar
2: Margetts, B, Nelson, M. Design Concepts in Nutritional Epidemiology. Oxford: Oxford Medical Publications, 1991.Google Scholar
3: Anderson, AS, Lean, MEJ, Vespasiani, G, Bruni, M, Martin, M. Foodmeter (UK) 2: a practical method of assessing dietary intake for patients with diabetes. Practical Diabetes 1993; 18(6): 234–6.CrossRefGoogle Scholar
4: Holland, B, Welch, AA, Unwin, ID, Buss, DH, Paul, AA, Southgate, DAT. McCance and Widdowson's The Composition of Foods, 5th edn.Cambridge: Royal Society of Chemistry and Ministry of Agriculture, Fisheries and Food, 1991.Google Scholar
5: Ministry of Agriculture, Fisheries and Food. Food Portion Sizes, 2nd edn.London: HMSO, 1994.Google Scholar
6: Ministry of Agriculture, Fisheries and Food. National Food Survey 1994. London: HMSO, 1996.Google Scholar
7: Eddington, J, Thorogood, M, Geekie, M, Ball, M, Mann, J. Assessment of nutritional intake using dietary records with estimated weights. J. Hum. Nutr. Diet. 1989; 61: 407–14.Google Scholar
8: Talwar, D, Cooney, J, O'Reilly, D StJ. Simultaneous determination of vitamins A and E and carotenoids in plasma by reversed phase HPLC. In: Proceedings of the Association of Clinical Biochemists National Meeting 88, 1995.Google Scholar
9: Gregory, J, Foster, K, Tyler, H, Wiseman, M. The Dietary and Nutritional Survey of British Adults. London: HMSO, 1990.Google Scholar
10: Di Mascio, P, Kaiser, S, Sies, H. Lycopene as the most efficient biological carotenoid single oxygen quencher. Arch. Biochem. Biophys. 1989; 274: 532–8.CrossRefGoogle Scholar
11: Thurnham, DI. Impact of disease on markers of micronutrient status. Proc. Nutr. Soc. 1996; 56: 421–31.CrossRefGoogle Scholar
12: Scott, KJ, Thurnham, DI, Hart, DJ, Bingham, SA, Day, K. The correlations between the intake of lutein, lycopene and beta-carotene from vegetables and fruits, and blood plasma concentrations in a group of women aged 50–65 years in the UK. Br. J. Nutr. 1996; 75: 409–18.CrossRefGoogle Scholar
13: Office of Population Censuses and Surveys and the Employment Department Group. OPCS Standard Occupational Classification. London: HMSO, 1990.Google Scholar