Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-25T16:53:55.819Z Has data issue: false hasContentIssue false

The big chill: Growth of in situ structural biology with cryo-electron tomography

Published online by Cambridge University Press:  13 December 2024

Mikhail Kudryashev*
Affiliation:
In situ Structural Biology, Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany Institute of Medical Physics and Biophysics, Charite–Universitatsmedizin Berlin, corporate member of Freie Universitat Berlin and Humboldt Universitat zu Berlin, Institute for Medical Physics and Biophysics, Berlin, Germany
*
Corresponding author: Mikhail Kudryashev; Email: mikhail.kudryashev@mdc-berlin.de
Rights & Permissions [Opens in a new window]

Abstract

In situ structural biology with cryo-electron tomography (cryo-ET) and subtomogram averaging (StA) is evolving as a major method to understand the structure, function, and interactions of biological molecules in cells in a single experiment. Since its inception, the method has matured with some stellar highlights and with further opportunities to broaden its applications. In this short review, I want to provide a personal perspective on the developments in cryo-ET as I have seen it for the last ~20 years and outline the major steps that led to its success. This perspective highlights cryo-ET with my eyes as a junior researcher and my view on the present and past developments in hardware and software for in situ structural biology with cryo-ET.

Type
Perspective
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press

Introduction and personal history

In 2005, I was about to complete my physics degree at an institution now called Siberian Federal University (Russia) when EMBL Heidelberg (Germany) invited me to a PhD student interview. My initial intention was to develop myself as a bioinformatician in one of the then-already famous groups; however, Achilleas Frangakis showed me cryo-electron tomography (cryo-ET) and got me excited with the fact that they were noisy, with an anisotropic resolution, and definitely needed computational processing (Frangakis, Reference Frangakis2021). However, I failed the final interview to EMBL. Yet, the challenge of cryo-ET and the promise to visualize molecules inside cells at high resolution (Grünewald et al., Reference Grünewald, Medalia, Gross, Steven and Baumeister2003) were fascinating. Luckily, a malaria biologist, Freddy Frischknecht, recruited me as one of his first PhD students at Heidelberg University (Germany). We collaborated with Wolfgang Baumeister’s department at the Max Planck Institute for Biochemistry, where the pioneering work on establishing cryo-ET was ongoing. This was the start of my cryo-EM journey. My PhD project focused on how Plasmodium sporozoites, the infectious stages of the malaria parasite transmitted from a mosquito to a host, move. Unlike most eukaryotic cells, sporozoites are thin enough to be imaged by cryo-ET. The research was exploratory, and we did not know what we were going to find if anything at all. However, as this was potentially a good application of cryo-ET, my co-PI Marek Cyrklaff convinced Wolfgang Baumeister to give me a guest contract to visit MPIB. We froze grids in our lab in Heidelberg, traveled to Munich with a dryshipper, and mostly booked night shifts as this was the only time when the microscope was free. On a good shift, I could record two to four tomograms with a total of ~140 during my PhD. Currently, we can record this much data in one session.

We were successful in the generation of tomographic data and could observe large molecules and organelles inside parasites (Figure 1). By looking at microtubules, we realized that they had an extra density inside (Cyrklaff et al., Reference Cyrklaff, Kudryashev, Leis, Leonard, Baumeister, Menard, Meissner and Frischknecht2007) suggesting the presence of microtubule inner proteins. These were later identified by Wang et al. in the related parasite Toxoplasma gondii (Wang et al., Reference Wang, Fu, Beatty, Ma, Brown, Sibley and Zhang2021). We discovered that microtubules and most organelles are located at a fixed distance from the parasite’s inner membrane complex, suggesting the presence of a linker molecule (Kudryashev et al., Reference Kudryashev, Lepper, Stanway, Bohn, Baumeister, Cyrklaff and Frischknecht2010c). Interestingly, parasites, when isolated, glide on solid support preferably in a counterclockwise direction (Hegge et al., Reference Hegge, Kudryashev, Smith and Frischknecht2009). We found that the arrangement of the microtubules around the Plasmodium-specific microtubule-organizing center creates a stiff ‘cage’ on the support, on which they glide (Kudryashev et al., Reference Kudryashev, Münter, Lemgruber, Montagna, Stahlberg, Matuschewski, Meissner, Cyrklaff and Frischknecht2012). I always found tomograms fascinating – they contain all the information about protein structures in a cell, although at limited resolution. We often observed proteins that we could attribute to textbook molecules, such as ribosomes, nuclear pore complexes, connections between microtubules and transport vesicles (Figure 1c, d), and many unidentified features or features that were at the edge of the resolution limit such as repetitive structures within the polar rings that have now been resolved (Martinez et al., Reference Martinez, Chen, Cova, Molnár, Mageswaran, Guérin, John, Lebrun and Chang2022). Plasmodium sporozoites move using their own actin machinery and we wanted to visualize it, however, we could never see them under the parasite plasma membrane, where they were expected (Figure 1e). From this, we concluded that they must be rather short (Kudryashev et al., Reference Kudryashev, Lepper, Baumeister, Cyrklaff and Frischknecht2010b). Indeed, only recent tomograms revealed their presence (Martinez et al., Reference Martinez, Mageswaran, Guérin, Chen, Thompson, Chavin, Soldati-Favre, Striepen and Chang2023). Overall, the high-resolution cell biology of Plasmodium sporozoites was highly informative and we published the last tomograms 9 years after I defended my PhD (Kehrer et al., Reference Kehrer, Kuss, Andres-Pons, Reustle, Dahan, Devos, Kudryashev, Beck, Mair and Frischknecht2018) with a number of them remaining unpublished. Recent developments in cryo-EM/ET made the technologies much more accessible, enabling many excellent groups to produce amazing tomograms and structures at higher resolution and gain insights into the molecular architecture of malaria parasites (Anton et al., Reference Anton, Cheng, Haile, Cobb, Zhu, Han, Li, Nair, Lee, Ke, Zhang, Doud and Ho2023; Ferreira et al., Reference Ferreira, Pražák, Vasishtan, Siggel, Hentzschel, Binder, Pietsch, Kosinski, Frischknecht, Gilberger and Grünewald2023; Wang et al., Reference Wang, Fu, Beatty, Ma, Brown, Sibley and Zhang2021; Martinez et al., Reference Martinez, Chen, Cova, Molnár, Mageswaran, Guérin, John, Lebrun and Chang2022; Sun et al., Reference Sun, Segev-Zarko, Pintilie, Kim, Staggers, Schmid, Egan, Chiu and Boothroyd2024) and it is fascinating to see the developments.

Figure 1. Molecular architecture of the apical end of a Plasmodium berghei sporozoite.

(a, b) A slice through a tomogram of the apical end of a sporozoite (a) and its volume rendering (b). The labels point to PM, plasma membrane (blue); IMC, Inner membrane complex (yellow); Rho, Rhoptries (magenta); Mic, Micronemes (cyan); MT, Microtubules (green). Red highlights density between PM and IMC, also shown in e. Adapted from Kudryashev et al. (Reference Kudryashev, Lepper, Stanway, Bohn, Baumeister, Cyrklaff and Frischknecht2010c). (c) A slice through a tomogram of the central part of a sporozoite showing a part of a nucleus with an apparent nuclear pore complex (NPC), end of a microtubule (MT), and ribosome-looking particles. (d) Slices through tomograms showing a close distance between the microtubules (MT) and micronemes (Mic) with apparent connections. Scale bar: 50 nm. (e) A volume-rendered visualization of a side view onto the IMC with the removed PM. Red arrowheads point to the filament-like densities where actin filaments are expected. The direction of the electron beam is horizontal. Right: a projection of the EM density through the volume between the IMC and the PM. Scale bar: 100 nm. Panel adapted from Kudryashev et al. (Reference Kudryashev, Lepper, Baumeister, Cyrklaff and Frischknecht2010b).

In 2005, subtomogram averaging (StA) was implemented as a set of scripts allowing to obtain moderate-resolution structures of molecules in tomograms (Förster et al., Reference Förster, Medalia, Zauberman, Baumeister and Fass2005), and we had to try it. Yet, we did not find a protein complex that would be interesting, large, and abundant in our tomograms of malaria parasites. We therefore obtained very thin bacteria – spirochetes of the genus Borrelia, known for causing Lyme disease. Most bacteria, including spirochetes, move by rotating flagellar filaments by a large transmembrane protein complex called a bacterial flagellar motor (BFM). BFM is a fascinating molecular machine converting proton gradient across the bacterial inner membrane into mechanical rotation. The first structure in situ was reported by Grant Jensens’ group (Murphy et al., Reference Murphy, Leadbetter and Jensen2006), it was produced by averaging 20 particles with C16 symmetry and had a resolution of 7 nm. I thought that with more tomograms I could average more particles and improve the resolution. I collected ~35 tomograms over many sessions (Kudryashev et al., Reference Kudryashev, Cyrklaff, Baumeister, Simon, Wallich and Frischknecht2009) and produced a structure from 128 particles with C16 symmetry at a resolution of 4.6 nm (Kudryashev et al., Reference Kudryashev, Cyrklaff, Wallich, Baumeister and Frischknecht2010a). Roughly simultaneously, Jun Liu from Houston produced a much better structure at a resolution of 3.5 nm from a heroic effort of averaging over 1280 particles (Liu et al., Reference Liu, Lin, Botkin, McCrum, Winkler and Norris2009). It became clear that obtaining higher resolution structures is possible, and it would require a higher throughput of data collection and processing. Later work with modern equipment and much higher throughput resulted in even higher resolution structures, allowing the fitting of the atomic models of the components of BFM (Carroll et al., Reference Carroll, Nishikino, Guo, Zhu, Kojima, Homma and Liu2020; Guo et al., Reference Guo, Xu, Chang, Motaleb and Liu2022), and there seems to be more potential for further improvement.

When I finished my PhD in 2009, I was lucky to get a postdoc position with Henning Stahlberg at the Biozentrum Basel (Switzerland). Biozentrum had one of the first Titan Krios microscopes, and a part of Henning’s group had a technological inclination. Having access to the automated high-throughput instrument was promising to be able to record large tomographic datasets. At that point, one of the major bottlenecks became data processing – with increased throughput and larger sizes of digital volumes. In 2009, we used Av3 (Förster et al., Reference Förster, Medalia, Zauberman, Baumeister and Fass2005), a set of MATLAB-based scripts to align subtomograms to one reference on one CPU. It was intuitive, compact, and functional but required a certain computational background to use, and was slow and prone to overfitting, like many other cryo-EM packages at the time (Scheres & Chen, Reference Scheres and Chen2012). Another option IMOD/PEET (Nicastro et al., Reference Nicastro, Schwartz, Pierson, Gaudette, Porter and McIntosh2006) also worked, it had a graphical interface and was useful for teaching undergraduates, but did not allow the flexibility that we wanted.

Luckily, my office neighbor Daniel Castaño-Diez took the challenge to improve data processing for cryo-ET and StA. He was excited about the potential of GPU acceleration for 3D image processing before it became mainstream (Castaño-Díez et al., Reference Castaño-Díez, Moser, Schoenegger, Pruggnaller and Frangakis2008). Daniel developed a set of tools now known as Dynamo – a GPU-accelerated package for StA that ran on clusters (Castaño-Díez et al., Reference Castaño-Díez, Kudryashev, Arheit and Stahlberg2012) and was much faster than CPU-based implementations. Dynamo had a graphical user interface, enabling scientists without coding expertise to use it. Dynamo changed the way we worked: before Dynamo we would start a subtomogram alignment project for an overnight run, and with Dynamo, we could run it over a coffee break. Dynamo widened the bottleneck of StA, but it still required reconstructed tomograms and picked particles to start. Understanding these challenges, Daniel developed variable tools for particle picking and data management in Dynamo Catalogue (Castaño-Díez et al., Reference Castaño-Díez, Kudryashev and Stahlberg2017), which is still very useful in the majority of applications. Daniel first developed Dynamo for our in-house projects, and we naturally wanted others to use it too, and organized many workshops in Basel and around the world. This helped to understand the requirements of Dynamo users; however, the majority of users were onboarded to Dynamo only once it got a wiki page with documentation.

Equipped with the automated microscope and the tools to process data, we were excited to put them to good use. I thought that cryo-ET could make the biggest contribution to the structural analysis of protein complexes that are hard to purify, for example, large membrane protein complexes. We teamed up with Guy Cornelis’s group, prominent researchers in the field of bacterial secretion to determine the structure of the bacterial injectisome in pathogenic Yersinia enterocolitica. The injectisome, also known as the type 3 secretion system, is a multiprotein transmembrane complex that bacteria use to deliver their effectors (i.e., toxins) into the host cells. The injectisome is evolutionarily related to BFM (Cornelis, Reference Cornelis2006). We generated minicells that were smaller and provided higher contrast and determined a ~40 Å structure of the injectisome in cells. The structure showed significant flexibility of the part of the injectisome located between the bacterial inner and outer membranes, which we attributed to an adaptation to deal with the naturally occurring variations in the intermembrane distance (Kudryashev et al., Reference Kudryashev, Stenta, Schmelz, Amstutz, Wiesand, Castaño-Díez, Degiacomi, Münnich, Bleck, Kowal, Diepold, Heinz, Dal Peraro, Cornelis and Stahlberg2013). The injectisomes tended to form small clusters on the surface of the bacteria, which likely increased the total secretion efficiency (Kudryashev et al., Reference Kudryashev, Diepold, Amstutz, Armitage, Stahlberg and Cornelis2015a). We then teamed up with Nans et al. who imaged pathogenic bacteria Chlamydia infecting human cells grown on grids. Such imaging naturally contained idle bacteria and those that infected cells, which allowed us to determine the moderate resolution structures of the injectisomes in their inactive and active states. Interestingly, the injectisomes in contact with the host cells had a shorter periplasmic part, suggesting that a ‘pump-action’ is required for secretion (Nans et al., Reference Nans, Kudryashev, Saibil and Hayward2015).

At the end of 2013, we got one of the first K2s – a direct electron detector (DED) from Gatan, at that moment – without an energy filter. I was about to join the group of Marek Basler, who just started his group in Biozentrum Basel. The focus of the group was the recently discovered bacterial secretion system type 6 (T6SS), which is similar to an inverted bacteriophage tail (Brunet et al., Reference Brunet, Hénin, Celia and Cascales2014), which bacteria use to kill each other (Basler et al., Reference Basler, Ho and Mekalanos2013, Reference Basler, Pilhofer, Henderson, Jensen and Mekalanos2012). Marek knew how to purify the T6SS sheath – a helical spring loaded with toxins that stored mechanical energy for a quick release. I prepared cryo-EM grids and collected ~250 micrographs manually over a Saturday on our new system. I have never done single-particle cryo-EM before, especially helical reconstruction, therefore we contacted an expert – Edward Egelman. Within weeks, we got the structure at 3.5 Å resolution (Kudryashev et al., Reference Kudryashev, Wang, Brackmann, Scherer, Maier, Baker, DiMaio, Stahlberg, Egelman and Basler2015b), which showed most side chains in the ordered part of the protein. In a way, the T6SS sheath is a perfect sample for single-particle cryo-EM as it is very stable and has helical and C6 symmetry. This is why a high-resolution structure could be obtained from the best 77 images. The field was still developing at the time and the software did not have hard blocks on the overfitting of maps, and the building of atomic models was usually done into X-ray maps. Therefore, we had to improvise on the aspects of image processing and building atomic models into the maps de novo (Wang et al., Reference Wang, Kudryashev, Li, Egelman, Basler, Cheng, Baker and DiMaio2015). Our early routines were using the data very efficiently, and only a small improvement in resolution from 3.5 to 3.3 Å was demonstrated with the later versions of helical refinement in Relion (He & Scheres, Reference He and Scheres2017).

A good way to think about structural biology and many other things is the framework of evolution. Max Perutz and John Kendrew solved structures of hemoglobin and myoglobin by X-ray crystallography, and it was a major effort to establish it starting from basic principles (Meurig Thomas, Reference Meurig Thomas and Meurig Thomas2020). X-ray crystallography defined structural biology for many years with a method mostly focused on relatively small soluble proteins. To facilitate the crystallization of more difficult targets, a proficient structural biologist had to optimize constructs, truncate domains, and introduce stabilizing mutations, which may limit the functionality of the resulting structures. The entire infrastructure of hardware (from crystallization robots to beamlines) and software for automatic data processing have been developed, making X-ray crystallography a very mature technique. Unwin and Henderson applied the crystallography approach to a crystalline purple membrane containing bacteriorhodopsin using electrons as probes (Henderson & Unwin, Reference Henderson and Unwin1975). This gave rise to a method of electron crystallography, motivating many researchers to grow 2D crystals of membrane proteins and image them in diffraction or imaging modes on an electron microscope (Abeyrathne et al., Reference Abeyrathne, Arheit, Kebbel, Castano-Diez, Goldie, Chami, Stahlberg, Renault, Kühlbrandt and Egelman2012). This technology was moderately successful, resulting in structures of many membrane proteins including 1.9 A structures of AQP0 (Gonen et al., Reference Gonen, Cheng, Sliz, Hiroaki, Fujiyoshi, Harrison and Walz2005) and interestingly, tubulin in a lattice (Nogales et al., Reference Nogales, Wolf and Downing1998). However, as 2D crystals of membrane proteins are generally hard to grow and screen, the method has become less popular over time. Small 3D crystals can be analyzed by microcrystal electron diffraction (microED), and the larger crystals can even be FIB-milled to reduce their thickness (Mu et al., Reference Mu, Gillman, Nguyen and Gonen2021), however, it still requires crystallization. Nuclear magnetic resonance (NMR) has also evolved as a structural biology method that is very successful for the structural analysis of proteins, including membranes. NMR requires a high concentration of stable protein and is limited in the sequence length (Marion, Reference Marion2013). Single-particle cryo-EM solved most of the problems of the existing methods: it required much less protein, and the protein did not have to be 100% pure and stable for days. Single-particle cryo-EM does not require crystallization, reveals structures of proteins in solution, and allows us to understand the structure and dynamics of macromolecules from one dataset. Eventually, electron microscopists transitioned from niche structural biologists studying ‘blobs’ to the ‘superstars’ of science, culminating with the award of the Nobel Prize in Chemistry in 2017 to the pioneers of cryo-EM. Single-particle cryo-EM was particularly successful in determining structures of membrane proteins and ion channels with the quintessential structure of the TRPV1 channel (Liao et al., Reference Liao, Cao, Julius and Cheng2013), as previously they were very hard to crystallize.

Inspired by single-particle cryo-EM, in 2015, I made a detour from cryo-ET and started a research group focusing on the structure and function of ion channels, which I thought were understudied and seemed like a good target for cryo-EM. With the cryo-EM hype and some luck, I got a big grant from the Alexander von Humboldt Foundation and recruited an amazing team to the Max Planck Institute of Biophysics in Frankfurt on Main. Notsurprisingly, membrane protein biochemistry proved to be hard: mammalian protein expression and purification are often very challenging and require a lot of optimization. Even when it works, there are day-to-day variability. A major challenge in determining the structure of a membrane protein is, therefore, not the cryo-EM work, but the quality of the protein. As a result, the competition in the field of cryo-EM of membrane proteins is immense, as many outstanding labs generate bright ideas and stable pure proteins. As a postdoc, I analyzed the structure of the serotonin receptor ion channel 5-HT3R, which instead of growing into 2D crystals, preferred to end up in small lipid vesicles. I, therefore, used cryo-ET and STA and determined the structure of 5-HT3R in lipids at a moderate resolution of 12 A. The structure was very similar to the previously reported X-ray structure at this resolution (Kudryashev et al., Reference Kudryashev, Castaño-Díez, Deluz, Hassaine, Grasso, Graf-Meyer, Vogel and Stahlberg2016). However, high-resolution single-particle analysis of 5-HT3R in a membrane mimetic saposin determined by Yingyi Zhang and Patricia Dijkman showed major differences from the previous structures without lipids. Functionally important cholesterol stabilizes the structure of 5-HT3R and together with phospholipids allows the ion-selective pore in the membrane to open and conduct ions (Zhang et al., Reference Zhang, Dijkman, Zou, Zandl-Lang, Sanchez, Eckhardt-Strelau, Köfeler, Vogel, Yuan and Kudryashev2021). Our groups determined several other important structures: together with the late Herman Bujard, we determined the structure of the malaria surface protein MSP1 (Dijkman et al., Reference Dijkman, Marzluf, Zhang, Chang, Helm, Lanzer, Bujard and Kudryashev2021), which he developed over 40 years into a malaria vaccine candidate currently undergoing clinical trials (Blank et al., Reference Blank, Fürle, Jäschke, Mikus, Lehmann, Hüsing, Heiss, Giese, Carter, Böhnlein, Lanzer, Haefeli and Bujard2020). Together with Volker Haucke, we determined the structure of a membrane-associated kinase PI3KC2α, which allowed us to suggest the mechanism of its action (Lo et al., Reference Lo, Zhang, Vadas, Roske, Gulluni, De Santis, Zagar, Stephanowitz, Hirsch, Liu, Daumke, Kudryashev and Haucke2022).

As amazing as single-particle cryo-EM is, I find that membrane protein biochemistry is a critical bottleneck. Depending on the purification protocol, the use of different detergents or membrane mimetic, lipid composition, and others, the structures can be different (Dalal et al., Reference Dalal, Arcario, Petroff, Tan, Dietzen, Rau, Fitzpatrick, Brannigan and Cheng2024; Hoffmann et al., Reference Hoffmann, Baier, Jorde, Kamel, Schäfer, Schnelle, Scholz, Shvarev, Wong, Parey, Januliene and Moeller2024). Therefore, the structures need to be critically evaluated for their physiological relevance. In my opinion, at the next iteration of structural biology, we can determine the structures of membrane proteins in membranes by skipping protein purification steps. This will allow us to obtain unambiguous structures of membrane proteins in lipid bilayers, potentially with the interacting partners or under physiological gradients. Our group at the Max Delbruck Center for Molecular Medicine in the Helmholtz Society in Berlin pushes ‘ways to means’ to determine the structures of membrane proteins in unrestricted membranes. For this, we experiment with display systems, from cryo-FIB milling into cells followed by cryo-ET, or by analyzing membrane proteins in purified native membranes, such as the vesicles of sarcoplasmic reticulum purified from rabbit muscle (Chen & Kudryashev, Reference Chen and Kudryashev2020; Sanchez et al., Reference Sanchez, Zhang, Chen, Dietrich and Kudryashev2020) or synaptic vesicles purified from mouse brains (Kravcenko et al., Reference Kravcenko, Ruwolt, Kroll, Yushkevich, Zenkner, Ruta, Lotfy, Wanker, Rosenmund, Liu and Kudryashev2024). As the structure determination methods are still being developed, it is clear that high-throughput and streamlined processing will be needed to average over many thousands of asymmetric particles; therefore, we develop automation tools, such as tomoBEAR (Balyschew et al., Reference Balyschew, Yushkevich, Mikirtumov, Sanchez, Sprink and Kudryashev2023). In some cases, the structures of proteins in membranes can be determined by single-particle cryo-EM, without recording tomograms (Mandala & MacKinnon, Reference Mandala and MacKinnon2022; Tao et al., Reference Tao, Zhao and MacKinnon2023; Yao et al., Reference Yao, Fan and Yan2020); however, there seem to be limits to the protein size and flexibility. Perhaps, hybrid StA (Sanchez et al., Reference Sanchez, Zhang, Chen, Dietrich and Kudryashev2020; Song et al., Reference Song, Shang, Fu, Lou, Grigorieff and Nicastro2020), combining some advantages of both imaging modalities will be useful for a class of proteins? We work on it while aiming to produce new insights into transmembrane signaling by medically important membrane proteins.

How cryo-ET and StA became great: Hardware and the interplay between academia and industrial developments

Conceptually, cryo-ET is simple: a sample, protein solution, or small organisms are frozen in a thin layer of amorphous ice; consecutive tilted transmission images are recorded, computationally aligned, and reconstructed into a 3D volume; multiple copies of the same molecules can be identified, mutually aligned and averaged (Walz et al., Reference Walz, Typke, Nitsch, Koster, Hegerl and Baumeister1997). However, the actual implementation was challenging. Tomograms have to be collected keeping the total electron dose limited, after each tilt of the microscope stage, the position of the sample has to be re-centered, and refocusing needs to be performed. Although heroes of early cryo-ET could collect tilt series manually (Cheng et al., Reference Cheng, Boll, Kirchhausen, Harrison and Walz2007), making cryo-ET practically useful required automation. The first tomography microscope at the Max Planck Institute for Biochemistry was a Phillips CM300 with a motorized ‘compuStage’, a CCD camera Gatan US1000, and a side-entry holder operated by in-house developed software. Side-entry holders are generally not designed to be tilted to 60°; therefore, liquid nitrogen used to cool it down started bubbling, pouring out at high tilts, and required refilling with liquid nitrogen every few hours. Replacing the grids with such a system took a significant time and was associated with diminishing the microscopes’ vacuum, practically limiting the throughput to three grids per day. Following this successful prototype, FEI (later purchased by Thermo Fisher Scientific) and JEOL designed more stable cold stages with multigrid capabilities. FEI Polara had a multispecimen holder, which was still hard to use, and it was easy to drop a cartridge with a grid inside the microscopy column. More modern microscopes with an autoloader are automated and allow to screen up to 12 grids per loading, which could be done more than once per session, it is a big factor for throughput.

The microscopes and cameras are fully computer-controlled, and the microscope producers maintain application programming interfaces (APIs) to allow external developers to control the devices. This open environment enabled academics to develop creative ideas for data collection, such as the automation packages Apion for single-particle cryo-EM (Lander et al., Reference Lander, Stagg, Voss, Cheng, Fellmann, Pulokas, Yoshioka, Irving, Mulder, Lau, Lyumkis, Potter and Carragher2009), TOM toolbox (Nickell et al., Reference Nickell, Förster, Linaroudis, Net, Beck, Hegerl, Baumeister and Plitzko2005), Leginon for tomography (Suloway et al., Reference Suloway, Shi, Cheng, Pulokas, Carragher, Potter, Zheng, Agard and Jensen2009), and the commonly used SerialEM (Mastronarde, Reference Mastronarde2005; Schorb et al., Reference Schorb, Haberbosch, Hagen, Schwab and Mastronarde2019). Building on the scripting capabilities of SerialEM enabled further improvements in tomography such as the dose-symmetric tilt scheme (Hagen et al., Reference Hagen, Wan and Briggs2017), which enabled the Briggs group to obtain the first sub-4 Å structure by cryo-ET (Schur et al., Reference Schur, Obr, Hagen, Wan, Jakobi, Kirkpatrick, Sachse, Kräusslich and Briggs2016). Scripting further enabled recording tomograms in parallel (Bouvette et al., Reference Bouvette, Liu, Du, Zhou, Sikkema, da Fonseca Rezende, Mello, Klemm, Huang, Schaaper, Borgnia and Bartesaghi2021; Eisenstein et al., Reference Eisenstein, Yanagisawa, Kashihara, Kikkawa, Tsukita and Danev2023; Khavnekar et al., Reference Khavnekar, Wan, Majumder, Wietrzynski, Erdmann and Plitzko2023), greatly increasing the throughput of data collection. This is borderline revolutionary and switched the challenge of cryo-ET from having enough time on the microscope to record the data to have enough computational resources to store and process all the data. Therefore, it is highly beneficial for both academic researchers and the industry to maintain APIs to further collaborate on innovations.

The detector quantum efficiency (DQE) of photographic film was generally comparable to or better than that of the CCD cameras of the early 2000s (McMullan et al., Reference McMullan, Chen, Henderson and Faruqi2009; Ruskin et al., Reference Ruskin, Yu and Grigorieff2013). There were first-generation FEI Titan Krios with chambers for photographic film, suggesting that some of the instruments were meant to screen the grids using CCD and to collect the data on film. The current generations of DED much surpass the DQE of film and provide high data collection speed, allowing recording ‘movies’ and correcting beam-induced motion (BIM; Brilot et al., Reference Brilot, Chen, Cheng, Pan, Harrison, Potter, Carragher, Henderson and Grigorieff2012; Zheng et al., Reference Zheng, Palovcak, Armache, Verba, Cheng and Agard2017). The development of DEDs is considered the major factor in the breakthrough of single-particle cryo-EM (Nogales, Reference Nogales2016). However, I would argue that for cryo-ET, without the parallel developments of automated microscopes, computer hardware, and software, the progress would not have been as impressive. As I discussed earlier, the automation of microscopy is much more important for tomography and it was already implemented on CCD cameras, DED gave a large boost in the resolution of final structures. I think that it is important to give credit to the industrial research and development teams who invested time and money to produce hardware at scale and robustly. My only concern with hardware and commercial software is that we need to ensure significant competition in the markets of microscopes, cameras, and software to keep the prices competitive for the limited research budgets.

The current frontiers of hardware technology include sample preparation for cryo-ET, especially for interesting and challenging samples ranging from cells to tissues. Following the pioneering developments of Marko et al. (Reference Marko, Hsieh, Schalek, Frank and Mannella2007), the department of Wolfgang Baumeister turned the milling of cryo-preserved samples with ions into a robust technology. Currently, milling into individual cells has become a commercially available technology. Further developments by the groups of Juergen Plitzko, Julia Mahamid, Alex Noble, Michael Grange, and others target the methods to image complex samples and multicellular organisms (Schiøtz et al., Reference Schiøtz, Kaiser, Klumpe, Morado, Poege, Schneider, Beck, Klebl, Thompson and Plitzko2023; Matsui et al., Reference Matsui, Spangler, Elferich, Shiozaki, Jean, Zhao, Qin, Zhong, Yu and Gouaux2024). While currently, it seems difficult, some of these technologies will become routinely useable sooner rather than later. Another potentially large step for cryo-ET is the development of a laser phase plate by the group of Holger Muller, which will allow the recording of data close to focus (Schwartz et al., Reference Schwartz, Axelrod, Campbell, Turnbaugh, Glaeser and Müller2019), further improving the quality of tomograms.

How cryo-ET and StA became great: Rise of software and software workflows

In July 2024, the EMDB depository (the wwPDB Consortium, 2024) had ~2185 subtomogram averages, slightly under 6% of all the depositions. The number of depositions grows fast and the resolution of the structures improves with years (Figure 2). The top 200 depositions have the resolution of 6.7 Å or higher. Such resolution allows for the resolving alpha-helices and a reasonable positioning of available atomic models. Many papers report subtomogram classifications resulting in multiple depositions of the same molecule from the same datasets. It highlights the power of cryo-ET and StA in the hands of several groups. There are many ‘favorite molecules’ of subtomogram average reports: purified apoferritin, lattices of rotaviruses such as GAG (Obr et al., Reference Obr, Hagen, Dick, Yu, Kotecha and Schur2022; Schur et al., Reference Schur, Obr, Hagen, Wan, Jakobi, Kirkpatrick, Sachse, Kräusslich and Briggs2016), and ribosomes (Gemmer et al., Reference Gemmer, Chaillet, van Loenhout, Cuevas Arenas, Vismpas, Gröllers-Mulderij, Koh, Albanese, Scheltema, Howes, Kotecha, Fedry and Förster2023; Tegunov et al., Reference Tegunov, Xue, Dienemann, Cramer and Mahamid2021; Xing et al., Reference Xing, Taniguchi, Khusainov, Kreysing, Welsch, Turoňová and Beck2023). I would also note actin filaments from sarcomeres in situ (Wang et al., Reference Wang, Grange, Pospich, Wagner, Kho, Gautel and Raunser2022), microtubules in axonemes (Tai et al., Reference Tai, Yin, Huang, Sun and Zhu2023) an archeal S-layer (von Kügelgen et al., Reference von Kügelgen, Cassidy, van Dorst, Pagani, Batters, Ford, Löwe, Alva, Stansfeld and Bharat2024), and a COPII coat (Hutchings et al., Reference Hutchings, Stancheva, Brown, Cheung, Miller and Zanetti2021). Highest resolution structures typically contain a large number of particles: 35,061 particles for a purified ribosome at 3.1 Å (EMD 33834); 286,400 particles for a ribosome in cells (3.1 Å resolution, EMD-16721); and 77,659*C6 for the CA-SP hexameric lattice at 2.9 Å resolution (EMD-14013). These are pioneering high-resolution structures, and except for apoferritin, provide insights into the structure of molecular complexes in situ. Interestingly, many deposited structures were part of publications in reputable journals (Figure 2).

Figure 2. Statistics of EMDB depositions for subtomogram averaging in July 2024.

I attribute the broader adoption of structural analysis by StA at higher resolution to the developments in software, which I break down into two 2 factors. The first factor – the software has become more usable. Many academic packages are good at doing one or a few operations. However, interfacing software responsible for multiple steps is not trivial and often requires scripting input and output to sometimes poorly documented packages. We previously estimated that processing of cryo-ET and StA datasets may include up to 16 steps of various difficulty and computational complexity (Leigh et al., Reference Leigh, Navarro, Scaramuzza, Chen, Zhang, Castaño-Díez and Kudryashev2019). To my knowledge, many successful StA labs had in-house solutions based on MATLAB or bash scripts, which are hard to maintain or modify for the new versions of infrastructure or other packages. Such sets of scripts are hard to transfer to another system, and there is a risk that once a scientist who wrote them leaves the group – they will be unusable. The development of workflows, covering multiple steps of data processing, such as IMOD/PEET (Heumann et al., Reference Heumann, Hoenger and Mastronarde2011; Mastronarde & Held, Reference Mastronarde and Held2017), EMAN2 (Chen et al., Reference Chen, Bell, Shi, Sun, Wang and Ludtke2019), pyTom (Hrabe et al., Reference Hrabe, Chen, Pfeffer, Cuellar, Mangold and Förster2012), emClarity (Ni et al., Reference Ni, Frosio, Mendonça, Sheng, Clare, Himes and Zhang2022), Dynamo (Scaramuzza & Castaño-Díez, Reference Scaramuzza and Castaño-Díez2021), Warp-Relion-M (Tegunov et al., Reference Tegunov, Xue, Dienemann, Cramer and Mahamid2021), TomoBEAR (Balyschew et al., Reference Balyschew, Yushkevich, Mikirtumov, Sanchez, Sprink and Kudryashev2023), nextPYP (Liu et al., Reference Liu, Zhou, Huang, Piland, Jin, Mandel, Du, Martin and Bartesaghi2023), Relion5 (Burt et al., Reference Burt, Toader, Warshamanage, von Kügelgen, Pyle, Zivanov, Kimanius, Bharat and Scheres2024), TOMOMAN (Khavnekar & Wan, Reference Khavnekar and Wan2024), and others makes the processing more accessible. There are many advantages of using a workflow, among others: potentially optimized execution with the reduced requirement for computational resources and storage; more reliability and reproducibility, better documentation, and an easier learning curve for new researchers. To obtain thousands to hundreds of thousands of asymmetric units for averaging to obtain a high-resolution structure, a large degree of automation is required.

The second aspect of the software is the opportunity to refine the structures to high resolution, making the method attractive to many biological applications. Here, two main challenges exist: computational costs and the accounting for the beam-BIM. Large computational resources are spent for the maximization of 3D cross-correlation (CC): a template is rotated to a set of angles, filtered, and distorted by a missing wedge, and the CC between it and the particle is calculated in 3D by convolution in Fourier space. The maximal CC value determines the optimal angles, whereas the position of the CC peak determines the shifts. Importantly, multiple 3D rotations and 3D Fourier transforms need to be calculated to perform CC maximization. When reaching high resolution in StA, the number of informative voxels in a volume increases, increasing the size of the ‘box’ with the particles. Practically, the largest currently deposited structures in EMDB are in the range of 400 voxels3, further processing is limited by the memory of graphical processors and, given the need to average over large datasets, the speed of processing altogether. This limitation can be partially circumvented by reducing the calculator of 3D CC to a set of 2D CCs. In the context of cryo-ET, it was first suggested by Ricardo Sanchez from our group (Sánchez et al., Reference Sánchez, Mester, Kudryashev, Felsberg, Forssén, Sintorn and Unger2019a, Reference Sánchez, Mester and Kudryashev2019b) and used in high-end processing packages such as ‘M’ (Tegunov et al., Reference Tegunov, Xue, Dienemann, Cramer and Mahamid2021) and Relion 4/5 (Burt et al., Reference Burt, Toader, Warshamanage, von Kügelgen, Pyle, Zivanov, Kimanius, Bharat and Scheres2024), reducing the computational complexity of the algorithm from L3 to L2, where L is the size of the volume. Still, further improvements in algorithms and their implementations are needed to reduce the computational and environmental load of StA and to make StA accessible to more groups that do not have access to large computational resources.

Accounting for BIM in tomography is arguably more difficult than in 2D single-particle cryo-EM, as the motion is 3D (Brilot et al., Reference Brilot, Chen, Cheng, Pan, Harrison, Potter, Carragher, Henderson and Grigorieff2012; Zheng et al., Reference Zheng, Palovcak, Armache, Verba, Cheng and Agard2017) and tomographic imaging is performed at tilts. Furthermore, cryo-ET imaging is performed on something more difficult than purified proteins, therefore the motion of the sample could be non-trivial, although it is not well described. Tomography-specific implementation of motion correction by ‘constrained single-particle-cryo-ET’ was first suggested by Bartesaghi et al. (Reference Bartesaghi, Lecumberry, Sapiro and Subramaniam2012). Alignment parameters of the tilt series were refined based on their fit to the final structure, resulting in a ~ 8 Å structure of GroEL from CCD data. This elegant algorithm has not been utilized for a decade, and it was recently reimplemented in a workflow nextPYP (Liu et al., Reference Liu, Zhou, Huang, Piland, Jin, Mandel, Du, Martin and Bartesaghi2023). A similar approach was suggested in emClarity: local refinement of tilt series alignment parameters based on the fit of the particles in 2D projections to the final structure, leading by iterative refinement (Himes & Zhang, Reference Himes and Zhang2018). ‘M’ by Tegunov et al. further improved the BIM refinement by incorporating several distortions for several types of molecules into one cost function and introduced an elegant filtering of half-maps during subtomogram alignment (Tegunov et al., Reference Tegunov, Xue, Dienemann, Cramer and Mahamid2021). EMAN2 introduced the direct ‘subtilt’ refinement of 2D projections and CTF parameters of particles versus the structure (Chen et al., Reference Chen, Bell, Shi, Sun, Wang and Ludtke2019). Relion 4/5 introduced Bayesian priors for motion between the neighboring particles in tomograms to prevent overfitting, resulting in improved reliability & precision (Burt et al., Reference Burt, Toader, Warshamanage, von Kügelgen, Pyle, Zivanov, Kimanius, Bharat and Scheres2024).

As powerful as cryo-ET is for the highlight applications, in my opinion, the range of molecules potentially amenable for the analysis by StA is still limited to the ‘favorite molecules’ which are stable, abundant, and large or periodic assemblies. Such molecules can be identified by automatic algorithms (Chen et al., Reference Chen, Dai, Sun, Jonasch, He, Schmid, Chiu and Ludtke2017; de Teresa-Trueba et al., Reference de Teresa-Trueba, Goetz, Mattausch, Stojanovska, Zimmerli, Toro-Nahuelpan, Cheng, Tollervey, Pape, Beck, Diz-Muñoz, Kreshuk, Mahamid and Zaugg2023; Moebel et al., Reference Moebel, Martinez-Sanchez, Lamm, Righetto, Wietrzynski, Albert, Larivière, Fourmentin, Pfeffer, Ortiz, Baumeister, Peng, Engel and Kervrann2021), can be easily computationally aligned to templates, and further refined to high resolution. In a way, there are similar limits of molecular weight to be able to identify a particle of interest and to align it to a template. However, an average protein in a cell is ~50 kDa, as a monomer (Kozlowski, Reference Kozlowski2017), which is much smaller than the highlighted applications and is present in cells (and tomograms) in low copy numbers (Wiśniewski et al., Reference Wiśniewski, Hein, Cox and Mann2014). Alignment of particles to an average is a particular challenge for membrane proteins and the membrane has high contrast (Chang et al., Reference Chang, Dijkman, Wiessing and Kudryashev2023). In fact, the average structure deposited to EMDB in 2024 has a resolution of ~20 Å. Such structures are also highly useful, especially as atomic models of proteins and complexes can be predicted by Alphafol3 (Abramson et al., Reference Abramson, Adler, Dunger, Evans, Green, Pritzel, Ronneberger, Willmore, Ballard, Bambrick, Bodenstein, Evans, Hung, O’Neill, Reiman, Tunyasuvunakool, Wu, Žemgulytė, Arvaniti, Beattie, Bertolli, Bridgland, Cherepanov, Congreve, Cowen-Rivers, Cowie, Figurnov, Fuchs, Gladman, Jain, Khan, Low, Perlin, Potapenko, Savy, Singh, Stecula, Thillaisundaram, Tong, Yakneen, Zhong, Zielinski, Žídek, Bapst, Kohli, Jaderberg, Hassabis and Jumper2024) or other approaches.

Future of in situ structural biology with cryo-ET: a broadly used method for biological discovery

Methods such as X-ray crystallography, and single-particle cryo-EM matured somehow similar to cryo-ET. At first, the basic concepts and prototype hardware and software were developed by pioneers, followed by the commercialization or open-sourcing of the tools, making the technologies generally accessible. I believe that currently in situ structural biology with cryo-ET passed the early steps of reaching general accessibility. Sample preparation and microscopes have become robust and highly productive. Importantly, several initiatives enabled shared access to microscopes (Zimanyi et al., Reference Zimanyi, Kopylov, Potter, Carragher and Eng2022), such as EMBL, NECEN, eBIC, Simons Electron Microscopy Center, and NIH. This means that any researcher can record several hundreds of high-quality tomograms of their sample of interest for a reasonable fee under the supervision of an expert. In the future, hardware will improve with newer detectors and phase plates; such add-ons would be easier to purchase and manage by larger cryo-EM/ET centers.

The major bottleneck for a new group interested in joining the cryo-ET community is data processing. Starting from storing terabyte-scale datasets, current software generally has a steep learning curve and requires large computing resources. The developments in making the software more stable, computationally efficient, and generally usable would provide benefits to the adoption of cryo-ET as a mainstream method. Graphical user interfaces and extensive documentation, like in IMOD, EMAN2, Dynamo, Relion5, and nextPYP, are key to enabling the users to take full advantage of the cryo-ET data. Importantly, many of the tasks in cryo-ET and StA are performed by conventional deterministic algorithms, such as CC-based tilt series alignment, template matching, subtomogram alignment-based CC maximization, and subtomogram classification using flavors of multireference alignment. Many of these operations can be performed by neural networks that can be either pretrained on large datasets or/and trained on a small part of the dataset of interest. Neural network inference is can be faster than CC, which will make processing less computationally demanding. Such implementations of neural networks would work best as a part of an integrated workflow.

Ultimately, as hardware and software will become better, we will be able to see more details in tomograms. On thin samples, perhaps from milled preparations, we will be able to observe molecules and individual domains in situ. Annotating 3D volumes manually is difficult and we will need to use algorithms to build atomic models of macromolecular complexes into tomograms. For this purpose, complementary information about protein structure and flexibility, protein–protein interactions, cellular localization, and other factors could be integrated into dedicated multimodal neural networks. Identified proteins could be further processed by StA. Such molecular mapping in situ will enable an understanding of the molecular landscapes of cells in high-resolution detail, which will become an important tool in molecular systems biology. In the future, understanding the cellular landscapes in detail will provide numerous insights into the molecular mechanisms of life and could allow for analyzing disease scenarios and suggesting therapeutic strategies.

Open peer review

To view the open peer review materials for this article, please visit http://doi.org/10.1017/qrd.2024.10.

Acknowledgments

The author thanks Vasilii Mikirtumov and Freddy Frischnkecht for their useful discussions and comments on the manuscript. This work was supported by DFG (Heisenberg grant, KU3222/3-1) and the Helmholtz Society.

Competing interest

The author declares no conflicts of interest.

References

Abeyrathne, PD, Arheit, M, Kebbel, F, Castano-Diez, D, Goldie, KN, Chami, M, Stahlberg, H, Renault, L and Kühlbrandt, W (2012) 1.15 analysis of 2-D crystals of membrane proteins by electron microscopy. In Egelman, EH (ed.), Comprehensive Biophysics. Amsterdam: Elsevier, pp. 277310.CrossRefGoogle Scholar
Abramson, J, Adler, J, Dunger, J, Evans, R, Green, T, Pritzel, A, Ronneberger, O, Willmore, L, Ballard, AJ, Bambrick, J, Bodenstein, SW, Evans, DA, Hung, C-C, O’Neill, M, Reiman, D, Tunyasuvunakool, K, Wu, Z, Žemgulytė, A, Arvaniti, E, Beattie, C, Bertolli, O, Bridgland, A, Cherepanov, A, Congreve, M, Cowen-Rivers, AI, Cowie, A, Figurnov, M, Fuchs, FB, Gladman, H, Jain, R, Khan, YA, Low, CMR, Perlin, K, Potapenko, A, Savy, P, Singh, S, Stecula, A, Thillaisundaram, A, Tong, C, Yakneen, S, Zhong, ED, Zielinski, M, Žídek, A, Bapst, V, Kohli, P, Jaderberg, M, Hassabis, D and Jumper, JM (2024) Accurate structure prediction of biomolecular interactions with AlphaFold 3. Nature 630, 493500.CrossRefGoogle ScholarPubMed
Anton, L, Cheng, W, Haile, MT, Cobb, DW, Zhu, X, Han, L, Li, E, Nair, A, Lee, CL, Ke, H, Zhang, G and Doud, EH and Ho, C-M (2023) Multiscale effects of perturbed translation dynamics inform antimalarial design. BioRxiv Preprint Server Biology. https://doi.org/10.1101/2023.09.03.556115CrossRefGoogle Scholar
Balyschew, N, Yushkevich, A, Mikirtumov, V, Sanchez, RM, Sprink, T and Kudryashev, M (2023) Streamlined structure determination by cryo-electron tomography and subtomogram averaging using TomoBEAR. Nature Communications 14, 6543.CrossRefGoogle ScholarPubMed
Bartesaghi, A, Lecumberry, F, Sapiro, G and Subramaniam, S (2012) Protein secondary structure determination by constrained single-particle Cryo-electron tomography. Structure (London, England) 20, 20032013.CrossRefGoogle ScholarPubMed
Basler, M, Ho, BT and Mekalanos, JJ (2013) Tit-for-tat: Type VI secretion system counterattack during bacterial cell-cell interactions. Cell 152, 884894.CrossRefGoogle ScholarPubMed
Basler, M, Pilhofer, M, Henderson, GP, Jensen, GJ and Mekalanos, JJ (2012) Type VI secretion requires a dynamic contractile phage tail-like structure. Nature 483, 182186.CrossRefGoogle ScholarPubMed
Blank, A, Fürle, K, Jäschke, A, Mikus, G, Lehmann, M, Hüsing, J, Heiss, K, Giese, T, Carter, D, Böhnlein, E, Lanzer, M, Haefeli, WE and Bujard, H (2020) Immunization with full-length plasmodium falciparum merozoite surface protein 1 is safe and elicits functional cytophilic antibodies in a randomized first-in-human trial. npj Vaccines 5, 10.CrossRefGoogle Scholar
Bouvette, J, Liu, H-F, Du, X, Zhou, Y, Sikkema, AP, da Fonseca Rezende, E, Mello, J, Klemm, BP, Huang, R, Schaaper, RM, Borgnia, MJ and Bartesaghi, A (2021) Beam image-shift accelerated data acquisition for near-atomic resolution single-particle cryo-electron tomography. Nature Communications 12, 1957.CrossRefGoogle ScholarPubMed
Brilot, AF, Chen, JZ, Cheng, A, Pan, J, Harrison, SC, Potter, CS, Carragher, B, Henderson, R and Grigorieff, N (2012) Beam-induced motion of vitrified specimen on holey carbon film.Journal of. Structural Biology 177, 630637.CrossRefGoogle Scholar
Brunet, YR, Hénin, J, Celia, H and Cascales, E (2014) Type VI secretion and bacteriophage tail tubes share a common assembly pathway. EMBO Reports 15, 315321.CrossRefGoogle Scholar
Burt, A, Toader, B, Warshamanage, R, von Kügelgen, A, Pyle, E, Zivanov, J, Kimanius, D, Bharat, TAM and Scheres, SHW (2024) An image processing pipeline for electron cryo-tomography in RELION-5. FEBS OpenBio. https://doi.org/10.1002/2211-5463.13873CrossRefGoogle Scholar
Carroll, BL, Nishikino, T, Guo, W, Zhu, S, Kojima, S, Homma, M and Liu, J (2020) The flagellar motor of vibrio alginolyticus undergoes major structural remodeling during rotational switching. eLife 9, e61446.CrossRefGoogle ScholarPubMed
Castaño-Díez, D, Kudryashev, M, Arheit, M and Stahlberg, H (2012) Dynamo: A flexible, user-friendly development tool for subtomogram averaging of cryo-EM data in high-performance computing environments. Journal of Structural Biology 178, 139151.CrossRefGoogle ScholarPubMed
Castaño-Díez, D, Kudryashev, M and Stahlberg, H (2017) Dynamo catalogue: Geometrical tools and data management for particle picking in subtomogram averaging of cryo-electron tomograms. Journal of Structural Biology 197, 135144.CrossRefGoogle ScholarPubMed
Castaño-Díez, D, Moser, D, Schoenegger, A, Pruggnaller, S and Frangakis, AS (2008) Performance evaluation of image processing algorithms on the GPU. Journal of Structural Biology 164, 153160.CrossRefGoogle ScholarPubMed
Chang, S-YS, Dijkman, PM, Wiessing, SA and Kudryashev, M (2023) Determining the structure of the bacterial voltage-gated sodium channel NaChBac embedded in liposomes by cryo electron tomography and subtomogram averaging. Scientific Reports 13, 11523.CrossRefGoogle ScholarPubMed
Chen, M, Bell, JM, Shi, X, Sun, SY, Wang, Z and Ludtke, SJ (2019) A complete data processing workflow for cryo-ET and subtomogram averaging. Nature Methods 16, 11611168.CrossRefGoogle ScholarPubMed
Chen, M, Dai, W, Sun, SY, Jonasch, D, He, CY, Schmid, MF, Chiu, W and Ludtke, SJ (2017) Convolutional neural networks for automated annotation of cellular cryo-electron tomograms. Nature Methods 14, 983985.CrossRefGoogle ScholarPubMed
Chen, W and Kudryashev, M (2020) Structure of RyR1 in native membranes. EMBO Reports. 21, e49891.CrossRefGoogle ScholarPubMed
Cheng, Y, Boll, W, Kirchhausen, T, Harrison, SC and Walz, T (2007) Cryo-electron tomography of clathrin-coated vesicles: Structural implications for coat assembly. Journal of Molecular Biology 365, 892899.CrossRefGoogle ScholarPubMed
Cornelis, GR (2006) The type III secretion injectisome. Nature Reviews Microbiology 4, 811825.CrossRefGoogle ScholarPubMed
Cyrklaff, M, Kudryashev, M, Leis, A, Leonard, K, Baumeister, W, Menard, R, Meissner, M and Frischknecht, F (2007) Cryoelectron tomography reveals periodic material at the inner side of subpellicular microtubules in apicomplexan parasites. Journal of Experimental Medicine 204, 12811287.CrossRefGoogle ScholarPubMed
Dalal, V, Arcario, MJ, Petroff, JT, Tan, BK, Dietzen, NM, Rau, MJ, Fitzpatrick, JAJ, Brannigan, G and Cheng, WWL (2024) Lipid nanodisc scaffold and size alter the structure of a pentameric ligand-gated ion channel. Nature Communications 15, 25.CrossRefGoogle ScholarPubMed
de Teresa-Trueba, I, Goetz, SK, Mattausch, A, Stojanovska, F, Zimmerli, CE, Toro-Nahuelpan, M, Cheng, DWC, Tollervey, F, Pape, C, Beck, M, Diz-Muñoz, A, Kreshuk, A, Mahamid, J and Zaugg, JB (2023) Convolutional networks for supervised mining of molecular patterns within cellular context. Nature Methods 20, 284294.CrossRefGoogle ScholarPubMed
Dijkman, PM, Marzluf, T, Zhang, Y, Chang, S-YS, Helm, D, Lanzer, M, Bujard, H and Kudryashev, M (2021) Structure of the merozoite surface protein 1 from plasmodium falciparum. Science Advances 7, eabg0465.CrossRefGoogle ScholarPubMed
Eisenstein, F, Yanagisawa, H, Kashihara, H, Kikkawa, M, Tsukita, S and Danev, R (2023) Parallel cryo electron tomography on in situ lamellae. Nature Methods 20, 131138.CrossRefGoogle ScholarPubMed
Ferreira, JL, Pražák, V, Vasishtan, D, Siggel, M, Hentzschel, F, Binder, AM, Pietsch, E, Kosinski, J, Frischknecht, F, Gilberger, TW and Grünewald, K (2023) Variable microtubule architecture in the malaria parasite. Nature Communications 14, 1216.CrossRefGoogle ScholarPubMed
Förster, F, Medalia, O, Zauberman, N, Baumeister, W and Fass, D (2005) Retrovirus envelope protein complex structure in situ studied by cryo-electron tomography. Proceedings of the National Academy of Sciences 102, 47294734.CrossRefGoogle ScholarPubMed
Frangakis, AS (2021) It’s noisy out there! A review of denoising techniques in cryo-electron tomography. Journal of Structural Biology 213, 107804.CrossRefGoogle Scholar
Gemmer, M, Chaillet, ML, van Loenhout, J, Cuevas Arenas, R, Vismpas, D, Gröllers-Mulderij, M, Koh, FA, Albanese, P, Scheltema, RA, Howes, SC, Kotecha, A, Fedry, J and Förster, F (2023) Visualization of translation and protein biogenesis at the ER membrane. Nature 614, 160167.CrossRefGoogle ScholarPubMed
Gonen, T, Cheng, Y, Sliz, P, Hiroaki, Y, Fujiyoshi, Y, Harrison, SC and Walz, T (2005) Lipid–protein interactions in double-layered two-dimensional AQP0 crystals. Nature 438, 633638.CrossRefGoogle ScholarPubMed
Grünewald, K, Medalia, O, Gross, A, Steven, AC and Baumeister, W (2003) Prospects of electron cryotomography to visualize macromolecular complexes inside cellular compartments: Implications of crowding. Biophysical Chemistry 100, 577591.CrossRefGoogle ScholarPubMed
Guo, S, Xu, H, Chang, Y, Motaleb, MA and Liu, J (2022) FliL ring enhances the function of periplasmic flagella. Proceedings of the National Academy of Sciences 119, e2117245119.CrossRefGoogle ScholarPubMed
Hagen, WJH, Wan, W and Briggs, JAG (2017) Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averaging. Journal of Structural Biology 197, 191198.CrossRefGoogle ScholarPubMed
He, S and Scheres, SHW (2017) Helical reconstruction in RELION. Journal of Structural Biology 198, 163176.CrossRefGoogle ScholarPubMed
Hegge, S, Kudryashev, M, Smith, A and Frischknecht, F (2009) Automated classification of plasmodium sporozoite movement patterns reveals a shift towards productive motility during salivary gland infection. Biotechnology Journal 4, 903913.CrossRefGoogle ScholarPubMed
Henderson, R and Unwin, PNT (1975) Three-dimensional model of purple membrane obtained by electron microscopy. Nature 257, 2832.CrossRefGoogle ScholarPubMed
Heumann, JM, Hoenger, A and Mastronarde, DN (2011) Clustering and variance maps for cryo-electron tomography using wedge-masked differences. Journal of Structural Biology 175, 288299.CrossRefGoogle ScholarPubMed
Himes, BA and Zhang, P (2018) emClarity: Software for high-resolution cryo-electron tomography and subtomogram averaging. Nature Methods 15, 955961.CrossRefGoogle ScholarPubMed
Hoffmann, L, Baier, A, Jorde, L, Kamel, M, Schäfer, J-H, Schnelle, K, Scholz, A, Shvarev, D, Wong, JEMM, Parey, K, Januliene, D and Moeller, A (2024) The ABC transporter MsbA in a dozen environments. BioRxiv Preprint Server Biology. https://doi.org/10.1101/2024.06.20.599867CrossRefGoogle Scholar
Hrabe, T, Chen, Y, Pfeffer, S, Cuellar, LK, Mangold, A-V and Förster, F (2012) PyTom: A python-based toolbox for localization of macromolecules in cryo-electron tomograms and subtomogram analysis. Journal of Structural Biology 178, 177188.CrossRefGoogle ScholarPubMed
Hutchings, J, Stancheva, VG, Brown, NR, Cheung, ACM, Miller, EA and Zanetti, G (2021) Structure of the complete, membrane-assembled COPII coat reveals a complex interaction network. Nature Communications 12, 2034.CrossRefGoogle ScholarPubMed
Kehrer, J, Kuss, C, Andres-Pons, A, Reustle, A, Dahan, N, Devos, D, Kudryashev, M, Beck, M, Mair, GR and Frischknecht, F (2018) Nuclear pore complex components in the malaria parasite plasmodium berghei. Scientific Reports 8, 11249.CrossRefGoogle ScholarPubMed
Khavnekar, S and Wan, W (2024) TOMOMAN: a software package for large scale cryo-electron tomography data preprocessing, community data sharing, and collaborative computing. BioRxiv Preprint Server Biology, 2024.05.02.589639. https://doi.org/10.1101/2024.05.02.589639CrossRefGoogle Scholar
Khavnekar, S, Wan, W, Majumder, P, Wietrzynski, W, Erdmann, PS and Plitzko, JM (2023) Multishot tomography for high-resolution in situ subtomogram averaging. Journal of Structural Biology 215, 107911.CrossRefGoogle ScholarPubMed
Kozlowski, LP (2017) Proteome-pI: Proteome isoelectric point database. Nucleic Acids Research 45, D1112D1116.CrossRefGoogle ScholarPubMed
Kravcenko, U, Ruwolt, M, Kroll, J, Yushkevich, A, Zenkner, M, Ruta, J, Lotfy, R, Wanker, EE, Rosenmund, C, Liu, F and Kudryashev, M (2024) Molecular architecture of synaptic vesicles. BioRxiv Preprint Server Biology. doi:10.1073/pnas.2407375121CrossRefGoogle Scholar
Kudryashev, M, Castaño-Díez, D, Deluz, C, Hassaine, G, Grasso, L, Graf-Meyer, A, Vogel, H and Stahlberg, H (2016) The structure of the mouse serotonin 5-HT3 receptor in lipid vesicles. Structure (London England 1993) 24, 165170.CrossRefGoogle ScholarPubMed
Kudryashev, M, Cyrklaff, M, Baumeister, W, Simon, MM, Wallich, R and Frischknecht, F (2009) Comparative cryo-electron tomography of pathogenic Lyme disease spirochetes. Molecular Microbiology 71, 14151434.CrossRefGoogle ScholarPubMed
Kudryashev, M, Cyrklaff, M, Wallich, R, Baumeister, W and Frischknecht, F (2010a) Distinct in situ structures of the Borrelia flagellar motor. Journal of Structural Biology 169, 5461.CrossRefGoogle ScholarPubMed
Kudryashev, M, Diepold, A, Amstutz, M, Armitage, JP, Stahlberg, H and Cornelis, GR (2015a) Y ersinia enterocolitica type III secretion injectisomes form regularly spaced clusters, which incorporate new machines upon activation. Molecular Microbiology 95, 875884.CrossRefGoogle Scholar
Kudryashev, M, Lepper, S, Baumeister, W, Cyrklaff, M and Frischknecht, F (2010b) Geometric constrains for detecting short actin filaments by cryogenic electron tomography. PMC Biophysics 3, 6.CrossRefGoogle ScholarPubMed
Kudryashev, M, Lepper, S, Stanway, R, Bohn, S, Baumeister, W, Cyrklaff, M and Frischknecht, F (2010c) Positioning of large organelles by a membrane- associated cytoskeleton in plasmodium sporozoites. Cellular Microbiology 12, 362371.CrossRefGoogle ScholarPubMed
Kudryashev, M, Münter, S, Lemgruber, L, Montagna, G, Stahlberg, H, Matuschewski, K, Meissner, M, Cyrklaff, M and Frischknecht, F (2012) Structural basis for chirality and directional motility of plasmodium sporozoites. Cellular Microbiology 14, 17571768.CrossRefGoogle ScholarPubMed
Kudryashev, M, Stenta, M, Schmelz, S, Amstutz, M, Wiesand, U, Castaño-Díez, D, Degiacomi, MT, Münnich, S, Bleck, CK, Kowal, J, Diepold, A, Heinz, DW, Dal Peraro, M, Cornelis, GR and Stahlberg, H (2013) In situ structural analysis of the Yersinia enterocolitica injectisome. eLife 2, e00792.CrossRefGoogle ScholarPubMed
Kudryashev, M, Wang, RY-R, Brackmann, M, Scherer, S, Maier, T, Baker, D, DiMaio, F, Stahlberg, H, Egelman, EH and Basler, M (2015b) Structure of the type VI secretion system contractile sheath. Cell 160, 952962.CrossRefGoogle ScholarPubMed
Lander, GC, Stagg, SM, Voss, NR, Cheng, A, Fellmann, D, Pulokas, J, Yoshioka, C, Irving, C, Mulder, A, Lau, P-W, Lyumkis, D, Potter, CS and Carragher, B (2009) Appion: An integrated, database-driven pipeline to facilitate EM image processing. Journal of Structural Biology 166, 95102.CrossRefGoogle ScholarPubMed
Leigh, KE, Navarro, PP, Scaramuzza, S, Chen, W, Zhang, Y, Castaño-Díez, D and Kudryashev, M (2019) Subtomogram averaging from cryo-electron tomograms. Methods Cell Biology 152, 217259.CrossRefGoogle ScholarPubMed
Liao, M, Cao, E, Julius, D and Cheng, Y (2013) Structure of the TRPV1 ion channel determined by electron cryo-microscopy. Nature 504, 107112.CrossRefGoogle ScholarPubMed
Liu, H-F, Zhou, Y, Huang, Q, Piland, J, Jin, W, Mandel, J, Du, X, Martin, J and Bartesaghi, A (2023) nextPYP: A comprehensive and scalable platform for characterizing protein variability in situ using single-particle cryo-electron tomography. Nature Methods 20, 19091919.CrossRefGoogle ScholarPubMed
Liu, J, Lin, T, Botkin, DJ, McCrum, E, Winkler, H and Norris, SJ (2009) Intact flagellar motor of Borrelia burgdorferi revealed by cryo-electron tomography: Evidence for stator ring curvature and rotor/C-ring assembly flexion. Journal of Bacteriology 191, 50265036.CrossRefGoogle ScholarPubMed
Lo, W-T, Zhang, Y, Vadas, O, Roske, Y, Gulluni, F, De Santis, MC, Zagar, AV, Stephanowitz, H, Hirsch, E, Liu, F, Daumke, O, Kudryashev, M and Haucke, V (2022) Structural basis of phosphatidylinositol 3-kinase C2α function. Nature Structural and Molecular Biology 29, 218228.CrossRefGoogle ScholarPubMed
Mandala, VS and MacKinnon, R (2022) Voltage-sensor movements in the Eag Kv channel under an applied electric field. Proceedings of the National Academy of Sciences 119, e2214151119.CrossRefGoogle ScholarPubMed
Marion, D (2013) An introduction to biological NMR spectroscopy. Molecular Cell. Proteomics MCP 12, 30063025.CrossRefGoogle ScholarPubMed
Marko, M, Hsieh, C, Schalek, R, Frank, J and Mannella, C (2007) Focused-ion-beam thinning of frozen-hydrated biological specimens for cryo-electron microscopy. Nature Methods 4, 215217.CrossRefGoogle ScholarPubMed
Martinez, M, Chen, WD, Cova, MM, Molnár, P, Mageswaran, SK, Guérin, A, John, ARO, Lebrun, M and Chang, Y-W (2022) Rhoptry secretion system structure and priming in plasmodium falciparum revealed using in situ cryo-electron tomography. Nature Microbiology 7, 12301238.CrossRefGoogle ScholarPubMed
Martinez, M, Mageswaran, SK, Guérin, A, Chen, WD, Thompson, CP, Chavin, S, Soldati-Favre, D, Striepen, B and Chang, Y-W (2023) Origin and arrangement of actin filaments for gliding motility in apicomplexan parasites revealed by cryo-electron tomography. Nature Communications 14, 4800.CrossRefGoogle ScholarPubMed
Mastronarde, DN (2005) Automated electron microscope tomography using robust prediction of specimen movements. Journal of Structural Biology 152, 3651.CrossRefGoogle ScholarPubMed
Mastronarde, DN and Held, SR (2017) Automated tilt series alignment and tomographic reconstruction in IMOD. Journal of Structural Biology, Electron Tomography 197, 102113.CrossRefGoogle ScholarPubMed
Matsui, A, Spangler, CJ, Elferich, J, Shiozaki, M, Jean, N, Zhao, X, Qin, M, Zhong, H, Yu, Z and Gouaux, E (2024) Cryo-electron tomographic investigation of native hippocampal glutamatergic synapses. eLife 13, RP98458.CrossRefGoogle ScholarPubMed
McMullan, G, Chen, S, Henderson, R and Faruqi, AR (2009) Detective quantum efficiency of electron area detectors in electron microscopy. Ultramicroscopy 109, 11261143.CrossRefGoogle ScholarPubMed
Meurig Thomas, J (2020) Perutz and Kendrew: The heroic era of structural molecular biology. In Meurig Thomas, J (ed.), Architects of Structural Biology: Bragg, Perutz, Kendrew, Hodgkin. Oxford University Press, p. 0.CrossRefGoogle Scholar
Moebel, E, Martinez-Sanchez, A, Lamm, L, Righetto, RD, Wietrzynski, W, Albert, S, Larivière, D, Fourmentin, E, Pfeffer, S, Ortiz, J, Baumeister, W, Peng, T, Engel, BD and Kervrann, C (2021) Deep learning improves macromolecule identification in 3D cellular cryo-electron tomograms. Nature Methods 18, 13861394.CrossRefGoogle ScholarPubMed
Mu, X, Gillman, C, Nguyen, C and Gonen, T (2021) An overview of microcrystal electron diffraction (MicroED). Annual Review of Biochemistry 90, 431450.CrossRefGoogle ScholarPubMed
Murphy, GE, Leadbetter, JR and Jensen, GJ (2006) In situ structure of the complete Treponema primitia flagellar motor. Nature 442, 10621064.CrossRefGoogle ScholarPubMed
Nans, A, Kudryashev, M, Saibil, HR and Hayward, RD (2015) Structure of a bacterial type III secretion system in contact with a host membrane in situ. Nature Communications 6, 10114.CrossRefGoogle ScholarPubMed
Ni, T, Frosio, T, Mendonça, L, Sheng, Y, Clare, D, Himes, BA and Zhang, P (2022) High-resolution in situ structure determination by cryo-electron tomography and subtomogram averaging using emClarity. Nature Protocols 17, 421444.CrossRefGoogle ScholarPubMed
Nicastro, D, Schwartz, C, Pierson, J, Gaudette, R, Porter, ME and McIntosh, JR (2006) The molecular architecture of Axonemes revealed by Cryoelectron tomography. Science 313, 944948.CrossRefGoogle ScholarPubMed
Nickell, S, Förster, F, Linaroudis, A, Net, WD, Beck, F, Hegerl, R, Baumeister, W and Plitzko, JM (2005) TOM software toolbox: Acquisition and analysis for electron tomography. Journal of Structural Biology 149, 227234.CrossRefGoogle ScholarPubMed
Nogales, E (2016) The development of cryo-EM into a mainstream structural biology technique. Nature Methods 13, 2427.CrossRefGoogle ScholarPubMed
Nogales, E, Wolf, SG and Downing, KH (1998) Structure of the αβ tubulin dimer by electron crystallography. Nature 391, 199203.CrossRefGoogle ScholarPubMed
Obr, M, Hagen, WJH, Dick, RA, Yu, L, Kotecha, A and Schur, FKM (2022) Exploring high-resolution cryo-ET and subtomogram averaging capabilities of contemporary DEDs. Journal of Structural Biology 214, 107852.CrossRefGoogle ScholarPubMed
Ruskin, RS, Yu, Z and Grigorieff, N (2013) Quantitative characterization of electron detectors for transmission electron microscopy. Journal of Structural Biology 184, 385393.CrossRefGoogle ScholarPubMed
Sánchez, RM, Mester, R and Kudryashev, M (2019a) Fast cross correlation for limited angle tomographic data. In Felsberg, M, Forssén, P-E, Sintorn, I-M and Unger, J (eds.), Image Analysis. Cham: Springer International Publishing, pp. 415426.CrossRefGoogle Scholar
Sánchez, RM, Mester, R and Kudryashev, M (2019b) Fast Alignment of Limited Angle Tomograms by projected Cross Correlation. In 2019 27th European Signal Processing Conference (EUSIPCO). Presented at the 2019 27th European Signal Processing Conference (EUSIPCO), pp. 15. https://doi.org/10.23919/EUSIPCO.2019.8903041Google Scholar
Sanchez, RM, Zhang, Y, Chen, W, Dietrich, L and Kudryashev, M (2020) Subnanometer-resolution structure determination in situ by hybrid subtomogram averaging – single particle cryo-EM. Nature Communications 11, 3709.CrossRefGoogle ScholarPubMed
Scaramuzza, S and Castaño-Díez, D (2021) Step-by-step guide to efficient subtomogram averaging of virus-like particles with dynamo. PLoS Biology 19, e3001318.CrossRefGoogle ScholarPubMed
Scheres, SHW and Chen, S (2012) Prevention of overfitting in cryo-EM structure determination. Nature Methods 9, 853854.CrossRefGoogle ScholarPubMed
Schiøtz, OH, Kaiser, CJO, Klumpe, S, Morado, DR, Poege, M, Schneider, J, Beck, F, Klebl, DP, Thompson, C and Plitzko, JM (2023) Serial lift-out: Sampling the molecular anatomy of whole organisms. Nature Methods 21, 16841692.CrossRefGoogle ScholarPubMed
Schorb, M, Haberbosch, I, Hagen, WJH, Schwab, Y and Mastronarde, DN (2019) Software tools for automated transmission electron microscopy. Nature Methods 16, 471477.CrossRefGoogle ScholarPubMed
Schur, FKM, Obr, M, Hagen, WJH, Wan, W, Jakobi, AJ, Kirkpatrick, JM, Sachse, C, Kräusslich, H-G and Briggs, JAG (2016) An atomic model of HIV-1 capsid-SP1 reveals structures regulating assembly and maturation. Science 353, 506508.CrossRefGoogle ScholarPubMed
Schwartz, O, Axelrod, JJ, Campbell, SL, Turnbaugh, C, Glaeser, RM and Müller, H (2019) Laser phase plate for transmission electron microscopy. Nature Methods 16, 10161020.CrossRefGoogle ScholarPubMed
Song, K, Shang, Z, Fu, X, Lou, X, Grigorieff, N and Nicastro, D (2020) In situ structure determination at nanometer resolution using TYGRESS. Nature Methods 17, 201208.CrossRefGoogle ScholarPubMed
Suloway, C, Shi, J, Cheng, A, Pulokas, J, Carragher, B, Potter, CS, Zheng, SQ, Agard, DA and Jensen, GJ (2009) Fully automated, sequential tilt-series acquisition with Leginon, Journal of Structural Biology 167, 1118.CrossRefGoogle ScholarPubMed
Sun, SY, Segev-Zarko, L, Pintilie, GD, Kim, CY, Staggers, SR, Schmid, MF, Egan, ES, Chiu, W and Boothroyd, JC (2024) Cryogenic electron tomography reveals novel structures in the apical complex of plasmodium falciparum. MBio 15, e02864e02823.CrossRefGoogle ScholarPubMed
Tai, L, Yin, G, Huang, X, Sun, F and Zhu, Y (2023) In-cell structural insight into the stability of sperm microtubule doublet. Cell Discovery 9, 119.CrossRefGoogle ScholarPubMed
Tao, X, Zhao, C and MacKinnon, R (2023) Membrane protein isolation and structure determination in cell-derived membrane vesicles. Proceedings of the National Academy of Sciences 120, e2302325120.CrossRefGoogle ScholarPubMed
Tegunov, D, Xue, L, Dienemann, C, Cramer, P and Mahamid, J (2021) Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells. Nature Methods 18, 186193.CrossRefGoogle Scholar
The wwPDB Consortium (2024) EMDB—The electron microscopy data Bank. Nucleic Acids Research 52, D456D465.CrossRefGoogle Scholar
von Kügelgen, A, Cassidy, CK, van Dorst, S, Pagani, LL, Batters, C, Ford, Z, Löwe, J, Alva, V, Stansfeld, PJ and Bharat, TAM (2024) Membraneless channels sieve cations in ammonia-oxidizing marine archaea. Nature 630, 230236.CrossRefGoogle ScholarPubMed
Walz, J, Typke, D, Nitsch, M, Koster, AJ, Hegerl, R and Baumeister, W (1997) Electron tomography of single ice-embedded macromolecules: Three-dimensional alignment and classification. Journal of Structural Biology 120, 387395.CrossRefGoogle ScholarPubMed
Wang, RY-R, Kudryashev, M, Li, X, Egelman, EH, Basler, M, Cheng, Y, Baker, D and DiMaio, F (2015) De novo protein structure determination from near-atomic-resolution cryo-EM maps. Nature Methods 12, 335338.CrossRefGoogle ScholarPubMed
Wang, X, Fu, Y, Beatty, WL, Ma, M, Brown, A, Sibley, LD and Zhang, R (2021) Cryo-EM structure of cortical microtubules from human parasite toxoplasma gondii identifies their microtubule inner proteins. Nature Communications 12, 3065.CrossRefGoogle ScholarPubMed
Wang, Z, Grange, M, Pospich, S, Wagner, T, Kho, AL, Gautel, M and Raunser, S (2022) Structures from intact myofibrils reveal mechanism of thin filament regulation through nebulin. Science 375, eabn1934.CrossRefGoogle ScholarPubMed
Wiśniewski, JR, Hein, MY, Cox, J and Mann, M (2014) A “proteomic ruler” for protein copy number and concentration estimation without spike-in standards *. Molecular and Cellular Proteomics 13, 34973506.CrossRefGoogle Scholar
Xing, H, Taniguchi, R, Khusainov, I, Kreysing, JP, Welsch, S, Turoňová, B and Beck, M (2023) Translation dynamics in human cells visualized at high resolution reveal cancer drug action. Science 381, 7075.CrossRefGoogle Scholar
Yao, X, Fan, X and Yan, N (2020) Cryo-EM analysis of a membrane protein embedded in the liposome. Proceedings of the National Academy of Sciences 117, 1849718503.CrossRefGoogle ScholarPubMed
Zhang, Y, Dijkman, PM, Zou, R, Zandl-Lang, M, Sanchez, RM, Eckhardt-Strelau, L, Köfeler, H, Vogel, H, Yuan, S and Kudryashev, M (2021) Asymmetric opening of the homopentameric 5-HT3A serotonin receptor in lipid bilayers. Nature Communications 12, 1074.CrossRefGoogle Scholar
Zheng, SQ, Palovcak, E, Armache, J-P, Verba, KA, Cheng, Y and Agard, DA (2017) MotionCor2: Anisotropic correction of beam-induced motion for improved cryo-electron microscopy. Nature Methods 14, 331332.CrossRefGoogle ScholarPubMed
Zimanyi, CM, Kopylov, M, Potter, CS, Carragher, B and Eng, ET (2022) Broadening access to cryoEM through centralized facilities. Trends in Biochemical Sciences 47, 106116.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Molecular architecture of the apical end of a Plasmodium berghei sporozoite.(a, b) A slice through a tomogram of the apical end of a sporozoite (a) and its volume rendering (b). The labels point to PM, plasma membrane (blue); IMC, Inner membrane complex (yellow); Rho, Rhoptries (magenta); Mic, Micronemes (cyan); MT, Microtubules (green). Red highlights density between PM and IMC, also shown in e. Adapted from Kudryashev et al. (2010c). (c) A slice through a tomogram of the central part of a sporozoite showing a part of a nucleus with an apparent nuclear pore complex (NPC), end of a microtubule (MT), and ribosome-looking particles. (d) Slices through tomograms showing a close distance between the microtubules (MT) and micronemes (Mic) with apparent connections. Scale bar: 50 nm. (e) A volume-rendered visualization of a side view onto the IMC with the removed PM. Red arrowheads point to the filament-like densities where actin filaments are expected. The direction of the electron beam is horizontal. Right: a projection of the EM density through the volume between the IMC and the PM. Scale bar: 100 nm. Panel adapted from Kudryashev et al. (2010b).

Figure 1

Figure 2. Statistics of EMDB depositions for subtomogram averaging in July 2024.

Author comment: The big chill: Growth of in situ structural biology with cryo-electron tomography — R0/PR1

Comments

No accompanying comment.

Decision: The big chill: Growth of in situ structural biology with cryo-electron tomography — R0/PR2

Comments

No accompanying comment.

Author comment: The big chill: Growth of in situ structural biology with cryo-electron tomography — R1/PR3

Comments

Dear Editors,

Please find the updated version of my perspective. I addressed the useful minor comments of the reviewers and further polished the text of the manuscript.

Please keep me informed about the progress of the manuscript.

Best regards,

Misha Kudryashev

Decision: The big chill: Growth of in situ structural biology with cryo-electron tomography — R1/PR4

Comments

No accompanying comment.