Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-11T14:39:52.875Z Has data issue: false hasContentIssue false

Variability of the Ultraviolet Continuum and Emission Lines of NGC 3783

Published online by Cambridge University Press:  19 July 2016

G.A. Reichert*
Affiliation:
Universities Space Research Association NASA-GSFC, Code 668, Greenbelt, MD 20771

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

On behalf of the International AGN Watch, I report on the results of intensive ultraviolet spectral monitoring of the Seyfert 1 galaxy NGC 3783. The nucleus of NGC 3783 was observed with the International Ultraviolet Explorer satellite on a regular basis for a total of seven months, once every 4 days for the first 172 days and once every other day for the final 50 days. Significant variability was observed in both continuum and emission-line fluxes. The light curves for the continuum fluxes exhibited two well-defined local minima or “dips,” the first lasting ≲ 20 days and the second ≲ 4 days, with additional episodes of relatively rapid flickering of approximately the same amplitude. As in the case of NGC 5548 (the only other Seyfert galaxy that has been the subject of such an intensive, sustained monitoring effort), the largest continuum variations were seen at the shortest wavelengths, so that the continuum became “harder” when brighter. The variations in the continuum occurred simultaneously at all wavelengths (Δt < 2 days). Generally, the amplitude of variability of the emission lines was lower than (or comparable to) that of the continuum. Apart from Mg II (which varied little) and N V (which is relatively weak and badly blended with Lyα) the light curves of the emission lines are very similar to the continuum light curves, in each case with a small systematic delay or “lag.” As for NGC 5548, the highest ionization lines seem to respond with shorter lags than the lower ionization lines. The lags found for NGC 3783 are considerably shorter than those obtained for NGC 5548, with values of (formally) ∼ 0 days for He II+O III], and ∼ 4 days for Lyα, and C IV. The data further suggest lags of ∼ 4 days for Si IV+O IV], and 8–30 days for Si III]+C III]. Uncertainties in these quantities are likely to be of order 2–3 days for the stronger features (Lyα, C IV), and 3–4 days for the weaker ones (He II+O III], Si IV+O IV], Si III]+C III]). Mg II lagged the 1460 Å continuum by ∼ 9 days, although this result depends on the method of measuring the line flux, and may in fact be due to variability of the underlying Fe II lines. Correlation analysis further shows that the power density spectrum contains substantial unresolved power over time scales of ≲ 2 days, and that the character of the continuum variability may change with time.

Type
Poster Contributions: Variability
Copyright
Copyright © Kluwer 1994