No CrossRef data available.
Article contents
RETRACTED – Determination of geometrical margins in external beam radiotherapy for prostate cancer
Published online by Cambridge University Press: 04 December 2018
Abstract
The focus of this study is to find the optimal clinical tumour volume (CTV) to planning tumour volume (PTV) margins for precise radiotherapy treatment of prostate cancer. The geometrical shape of the target volume posses challenges in accurately identifying the CTV to PTV margins, especially when the organ affected by cancer demonstrates anatomical variations and the surrounding organs have high radio-sensitivity, in comparison to the organ of origin of the cancer.
The geometrical margins of CTV to PTV are investigated using portal imaging, in three directions. This study is carried out on 20 patients treated by the external photon beam radiotherapy of prostate cancer using standard accelerator without stereotaxic and without prostate markers.
Based on previous studies and the findings of our work, we propose CTV to PTV margin of 5·84 mm in the lateral direction, of 5·1 mm in the cranio-spinal direction and of 7·3 mm in the antero-posterior direction for external photon beam radiotherapy of prostate cancer.
The proposed CTV to PTV margins ensure high radiotherapy treatment precision of prostate cancer.
- Type
- Original Article
- Information
- Copyright
- © Cambridge University Press 2018
Footnotes
Cite this article: Bencheikh M, Maghnouj A, Tajmouati J, Dadouch A, Benjelloun Z. (2019) DETRACTED – Determination of geometrical margins in external beam radiotherapy for prostate cancer. Journal of Radiotherapy in Practice18: 186–189. doi: 10.1017/S1460396918000699
References
A correction has been issued for this article:
Linked content
Please note a has been issued for this article.