Introduction
It is well documented that female patients with mediastinal lymphoma who are treated with radiotherapy have an increased risk of developing a second primary breast cancer 1–Reference Conway, Connors, Tyldesley, Savage and Campbell10 . The risk of developing a second primary breast cancer from lymphoma radiotherapy depends upon the amount of dose received, with respect to the volume of tissue exposed Reference Verhappen, Poortmans, Raaijmakers and Raemaekers2,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . This means that variations in target delineation and treatment delivery techniques affect dose received by breast tissue and other organs at risk (OARs) Reference Verhappen, Poortmans, Raaijmakers and Raemaekers2–Reference Conway, Connors, Tyldesley, Savage and Campbell10 .
Acknowledgement of the late effect risk of developing second primary cancers, alongside other late toxicities, led to a drive to further reduce the size of the treatment volumes for patients receiving radiotherapy for mediastinal lymphoma. Initially, this meant going from an extended field radiotherapy (EFRT) technique covering most of the thorax with shielding for the lungs to involved field radiotherapy (IFRT) technique, which primarily involved just the localised region of original disease-involved nodes pre chemotherapy Reference Witkowska, Majchrza and Smolewski3,Reference Hoskin, Diez, Williams, Lucraft and Bayne4 (Figure 1). In a trial originally investigating the efficacy of IFRT Reference Engert, Schiller, Josting, Herrmann and Koch5 , 1064 patients with early-stage unfavourable Hodgkin lymphoma were randomised to be prescribed either 30Gy EFRT or IFRT after receiving 4 cycles of chemotherapy. No significant differences were found in overall survival, freedom from treatment failure and progression-free survival at the 10 years follow up. Moreover, treatment with IFRT had a significantly lower rate of acute toxicity, with a non-statistically significant lower rate of secondary malignancies in patients compared to EFRT Reference Engert, Schiller, Josting, Herrmann and Koch5,Reference Diehl6 . This led to IFRT becoming the gold standard in radiotherapy for treating nodal lymphomas in the UK from 2003 onwards Reference Hoskin, Diez, Williams, Lucraft and Bayne4 .
When computerised positron emission tomography (PET)-CT was implemented to aid diagnosis and staging, the full extent of disease-involved nodes could be visualised. It is known that most reoccurrences of lymphoma begin in the initially involved nodes Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . Therefore, it was hypothesised in several studies that treating only the initially involved nodes highlighted from the PET-CT scan could provide an equally effective treatment for lymphoma to IFRT in terms of disease-free survival, but with a further reduced dose to OAR Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . This led to the development of the treatment delineation technique involving node radiotherapy (INRT) where only the involved nodes, highlighted from the PET-CT scan, are treated (Figure 1) Reference Witkowska, Majchrza and Smolewski3,Reference Girinsky, van der Maazen, Specht, Aleman and Poortmans7,Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 . For INRT, it is required that the PET-CT scan take place in the original radiotherapy treatment position, which is ideal as it enables reproducibility of position on treatment Reference Specht, Yalahom, Illidge, Berthelsen and Constine9 . However, this is not always possible due to differences in equipment size and suitability and appointments and equipment being spread out across differing treatment centres, Reference Portlock8 which led to the development of involved site radiotherapy (ISRT), which is a less rigid version of INRT that does not require the PET-CT to take place in the radiotherapy treatment position, meaning the Gross Tumour Volume (GTV) information may not be fully optimal Reference Portlock8 . To this end, this can also mean that a larger Clinical Target Voume (CTV) is contoured compared to INRT for ISRT, based on clinical judgement and the imaging information available Reference Specht, Yalahom, Illidge, Berthelsen and Constine9 . Both INRT and ISRT are currently recommended by the International Lymphoma Radiation Oncology Group for treatment of lymphoma patients Reference Specht, Yalahom, Illidge, Berthelsen and Constine9,Reference Conway, Connors, Tyldesley, Savage and Campbell10 .
Currently, the Author’s Centre does not routinely record breast doses for female patients receiving radiotherapy for supradiaphragmatic lymphoma. Therefore, risks of a second primary breast cancer locally to these patients are unquantified. Although the aforementioned changes to target delineation and treatment delivery methods have been introduced to reduce dose to breast tissue, there is still an increased risk of second primary breast cancer at lower doses, even reportedly as low as 0·24Gy Reference Wirth, Kron, Wittwer, Sullivan, Sorrell and Cramb11 . Moreover, second primary breast cancers from lymphoma radiotherapy are more likely to be triple-negative and or bilateral than de novo primary breast cancers Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Horst, Hancock, Ognibene, Chen and Advani12 . This means these women are more likely to have a worse prognosis at diagnosis Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Horst, Hancock, Ognibene, Chen and Advani12,Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13 . Therefore we decided to audit breast dose in previously treated patients to allow for potential future investigations of risk and follow up care interventions to take place.
The aim of this study was to audit breast dose in women who have received external beam radiotherapy for nodal lymphoma involving the mediastinum at a single UK Cancer Centre and compare those to the literature.
The Objectives of this study were to:
-
Extract dose parameter values from suitable plans for comparison between patients.
-
Compare the combined dose parameter values found in this study to those in similar studies.
Methodology
Patient selection
A retrospective audit was conducted for female patients up to the age of 36 who were previously treated with external beam radiotherapy (EBRT) for nodal lymphoma involving the mediastinum. Patients were sourced from the trust’s Aria (Varian Medical Systems, Palo Alto, CA) patient database by utilising a database search report for patients who had lymphoma with mediastinal involvement between 2017 and 2021. Patients with lymphoma in the mediastinum were the focus of this study, due to the proximity of the mediastinum to the breast. Furthermore, examining patients with mediastinal lymphoma allows for comparison between studies found in the literature review as most studies examining breast dose in lymphoma patients focussed on patients with mediastinal involvement Reference Conway, Connors, Tyldesley, Savage and Campbell10,Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13 . Patients up to the age of 36 were selected initially due to the known increased risk of breast cancer 14 . This left only 7 patients who would have been eligible for inclusion into the audit out of the 23 patients treated with EBRT for mediastinal lymphoma. To expand the number of suitable patients for a larger sample size, the inclusion criteria were amended to instead include female-only patients of any age, due to women of all ages having breast tissue, along with a 30Gy prescription, and confirmed mediastinal involvement in their patient notes. Exclusion criteria included male patients, with incomplete breast tissue on their scan data due to a reduced amount of or incomplete amount of breast tissue on the CT dataset. Patients with no mediastinal involvement documented in their notes were excluded to enable comparison with other studies and due to a likelihood of limited breast tissue receiving dose for these patients and a prescription dose which was not 30Gy was also excluded to enable uniform comparison between patients without prescription dose influencing breast dose. All patients underwent a pre-radiotherapy CT scan of 3 mm slice thickness. Ethics approval was obtained from the author’s centre prior to data collection.
Plan information
Treatment plans used in this study were originally used for patient treatment and no changes were made to any of the original planning decisions. All treatments were planned in Eclipse v15·6 (Varian Medical Systems, Palo Alto, CA) using the Acuros dose algorithm. Treatment planning staff at the trust provided training on using Eclipse for the author to extract data from plan dose-volume histograms from the treatment plan and in utilising the contouring tools to outline breast tissue. Plans selected were either Intensity Modulated Radiotherapy (IMRT) fixed field or VMAT plans.
The dose parameters used for this study encompassed those at both lower and higher doses namely V4Gy, V5Gy, V20Gy, D1%, and mean dose Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15–Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . These parameters were utilised in the literature and allowed for effective comparison to other studies Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15–Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Descriptive statistics were utilised to enable comparison between patients. All plans utilised the target delineation method ISRT Reference Witkowska, Majchrza and Smolewski3,Reference Portlock8–Reference Conway, Connors, Tyldesley, Savage and Campbell10 . Acceptable dose limits to the PTV were between 95% and 107% in accordance with International Commission on Radiation Units and Measurements (ICRU) guidelines 20 . All plans selected for contouring were anonymised and copied to enable contouring of breast tissue. To allow for accurate anatomical boundaries to be adhered to in terms of contouring and enable repeatability in future studies, breast contouring in this study was conducted using a combination of RTOG and ESTRO breast contouring guidelines 21,Reference Offersen, Boersma, Kirkove, Hol and Aznar22 .
Results were recorded as either combined or separate breasts within the literature Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15–Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Therefore, to allow for comparisons between all studies within the review, breast dose results were reported as both combined and separate breasts in this audit. Patients with breast contours already outlined had new contours produced using the RTOG/ESTRO guidelines to ensure consistency in results 21,Reference Offersen, Boersma, Kirkove, Hol and Aznar22 . Combined breast contours were made by combining the left and right breast contours as a new structure.
Results
Patient information
The Aria database search post application of inclusion and exclusion criteria resulted in 23 eligible patients for selection. All plans selected were planned at 6MV. IMRT and VMAT separation data are found in Table 1. Three patients out of the 23 had breast contours already produced in their structure sets. These three patients were all 34 years of age or under at time of treatment. Two of these three patients had breast-related optimisation objectives in place to reduce dose to the breast tissue (Table 2). One patient’s plan was combined with their replan to form a single new plan.
Plan Analysis
Data for each patient regarding their individual dose parameter values can be found in Appendix 1–3. Means, medians, maximum and minimum values and ranges were calculated for each dose parameter for the left, right and combined breasts, using all plans. These can be found in Tables 3–5. Box plots of Interquartile range (IQR) data for each parameter for each breast were constructed to illustrate the distribution of the data (Figures 2 & 3).
Little difference in dose is noted between left and right breasts (Tables 3–5), (Figure 2). A greater volume of breast tissue is receiving around V4Gy and V5Gy compared to V20Gy and a larger range in values for V4Gy and V5Gy can also be noted compared to V20Gy (Figure 2). There is also a large range for right, left and combined breasts in terms of D1% (Tables 3–5) (Figure 3). Mean dose to breast tissue for the overall data appears to be just around 4Gy (Tables 3–5) (Figure 3).
A difference in V4Gy and V5Gy can be seen between fixed-field IMRT and VMAT treatment for left, right and combined breast data (Figure 4) in terms of the range and spread of the data. There is not much difference between treatment delivery modalities for V20Gy (Figure 4). A large range can also be seen for the D1% data with some values close to the prescription dose and some close to no dose received (Figure 5). There also appears to be a difference in mean dose received between fixed-field IMRT and VMAT (Figure 5).
Visual differences in the amount of breast tissue irradiated were well observed on aria between patients (Figures 6–8). Moreover, differences were noted between the contouring produced for this audit and that previously present on some patients (n = 3) (Figure 9)
Discussion
Trends in data in this audit suggest that there is little difference in breast dose received between left and right breasts (Figures 2 & 3). Previous studies reported differences in breast dose between left and right breasts in mediastinal-involved patients with a 30Gy prescription Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Koeck et al., found all parameters measured in all plans were greater for the left breast than the right Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Conversely, Voong et al., found similar values for the left and right breasts for each parameter measured Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 . The reasons behind these trends are not mentioned in these studies. However, it is important to note that breast tissue is not the primary target of treatment delivery for as the volume of individual or combined breast tissue irradiated is dependent upon field margin locations required to treat the target volume, which in turn is dependent on disease location, extent and each centre’s target volume margining used. It is also dependant on individual and combined breast contours, sizes, and geometric positions in relation to the location of the fields (Figure 6–8) with these factors being variable for all treatment techniques and patients. Therefore, there is always going to be variation between patients and between studies examining left, right and combined breast dose parameter values.
Differences in volume of breast tissue irradiated and mean dose between fixed-field IMRT and VMAT were noted within this study (Figures 4 & 5). Previous studies have suggested that the delivery technique does play a role in dose to breast tissue with VMAT resulting in an increased mean dose and V4Gy of breast tissue compared to other forms of IMRT Reference Fiandra, Filippi, Catuzzo, Botticella and Ciammella24,Reference Xu, Kang, Jiang, Liu and Li25 . Furthermore, FF-IMRT was found to increase median and low doses but reduce higher doses compared to 3D-CRT Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . A more recent study however, utilising ISRT, suggests there is little difference between 3D-CRT and VMAT, although this compared a parallel opposed pair at 0o and 180o which would avoid most of the breast tissue, but could lead to higher doses in other areas Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17 . The data in this study suggest mean dose and V4Gy are higher for VMAT patients (Figures 4 & 5). However, the data for fixed-field IMRT in this study is based upon just three patients and utilises a combination of IMRT and 3D-CRT patients. Moreover, in two of the three fixed-field IMRT plans, breast dose was taken into consideration by the planners of the original plan in efforts to reduce breast dose in one patient and avoid a singular breast in another due to previous XRT (Figure 8). Additionally, within this study, two patients received partial arcs and the number of arcs varied between one and three for some patients (Table 3). This could also have influenced dosimetry to breast tissue. Therefore, the comparisons displayed within this data between these factors should be taken very tentatively.
Data from previous studies that utilised ISRT to treat mediastinal lymphoma, within 0·6Gy of a 30Gy prescription dose, can be found within (Table 6) Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15–Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19 . Differences can be noted between the audit data and the literature, most notably in terms of V4% and V5% and mean dose (Table 6). It is important to mention that the literature data compiled in the above table contains data from studies utilising different treatment delivery methods, which have previously been noted to alter dose to breast tissue Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15–Reference Scorsetti, Cozzi, Navarria, Fogliata and Rossi19,Reference Fiandra, Filippi, Catuzzo, Botticella and Ciammella24,Reference Xu, Kang, Jiang, Liu and Li25 .
Differences observed between the overall combined data in this study such as a higher mean dose compared to that found within the literature (Table 6) could be partially due to this audit being primarily composed of VMAT-planned patients that did not utilise breast tissue as optimisation structure during the planning process (Table 1 & 2), as done in other VMAT planned studies Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17 . This could have instigated a higher dose VMAT-induced dose bath across breast tissue in these patients compared to the other studies which either utilised either a fixed-field Anterior-Posterior-Posterio-Anterior (AP-PA) approach, preventing a widespread low-dose bath from occurring, or had objectives in place to reduce dose to breast tissue with their multi-field IMRT or VMAT plans Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23 . Differences in contouring technique used could also impact this as most studies did not mention the method they utilised. Differences were noted in this work between patients with breast contours already produced compared to ones outlined utilising the RTOG & ESTRO guidelines (Figure 7) 20,21 .
Further work would be required to investigate the full clinical impact of the dosimetric differences noted between the data in this audit and other studies, which could be prudent for the younger patients within this group of patients. It has been suggested previously that for patients at the age of 20, 0·1Gy received to breast tissue can increase the lifetime risk of developing breast cancer by 0·4% Reference Sun, Wang, Qiu, Liang and Xie26 . Moreover, secondary breast cancers present the highest absolute excess risk of all secondary malignancies for women receiving supradiaphragmatic radiotherapy for Hodgkin’s lymphoma according to epidemiological data Reference Schaapveld, Aleman, van Eggermond, Janus and Krol27 .
It would be beneficial therefore to monitor breast dose in future for female patients receiving EBRT for mediastinal lymphoma and encompass dose to breast tissue in treatment planning algorithms. Due to the increased risk of secondary breast cancer and depending on other clinical factors patients who have received EBRT for mediastinal lymphoma could potentially be invited to begin breast screening process at an earlier age 14 . It is notable to mention that there did not appear to be clear differentiation when it came to why some patients had breast contouring and or optimisation objectives in place, as other patients with similar clinical attributes (such as age and stage) were not contoured or optimised with regard to breast dose in this audit. Position of the target volume in relation to breast tissue, however, may have played a role in some cases but not all patients without prior contours (Table 2).
Fundamentally, it is important to state that the risk of all secondary malignancies must be weighed against each other and against the risk of other conditions when considering patient treatment. As target delineation and delivery techniques change, doses received by OAR also change (Figure 1) Reference Murray, Sethugavalar, Robertshaw, Bayman and Thomas13,Reference Edvardsson, Kügele, Alkner, Enmark and Nilsson17,Reference Koeck, Abo-Madyan, Lohr, Stieler and Kriz23–Reference Xu, Kang, Jiang, Liu and Li25 . The treatment method chosen and construction of the dose objective optimisation algorithms should be based on an individual patient case basis. This decision for each individual should therefore consider individual clinical factors such as gender, age and other comorbidities, which may influence risk of secondary malignancy, alongside position of OAR’s in the treatment area Reference Schaapveld, Aleman, van Eggermond, Janus and Krol27 .
A novel way to reduce the volume of breast tissue in field could be to utilise an angled board for immobilisation. This was not utilised in this cohort but has been used in previous studies that demonstrated reduced dose to breast tissue from treatment delivery by positioning breast tissue further inferiorly Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 . However, utilising such a method for treatment delivery for VMAT patients may induce some potential collision-related issues due to the extension of the patient’s elbows vertically and laterally. Moreover, it has primarily been tested in conjunction with ‘butterfly technique’ IMRT, and therefore, it is difficult to determine the full extent of its sole impact from this data Reference Voong, Mcspadden, Pinnix, Shihadeh and Reed15 .
Unfortunately, there were a limited number of fixed-field IMRT patients that could be utilised to enable a more comprehensive comparison between the treatment delivery techniques utilised. Further audits in future may benefit from making a wider array of retrospective plans on a large cohort of patients to enable a more expansive comparison and enable greater testing of different fixed-field IMRT or VMAT variations to reduce dose to breast and other OAR and make results more generalisable with wider utility.
Conclusion
In conclusion, breast dose parameter values between patients in this study vary due to multiple factors. These include the treatment delivery method used and the position of the treatment field in relation to the location of breast tissue. Mean dose and V4% and V5% to breast tissue found in this study differ from that found in the literature, but this may be due to the choice of optimisation objectives at the planning stage and the contours utilised for the breast tissue. This study highlights the importance of accurate contouring and optimising breast tissue when possible. Further studies could be carried out to standardise some optimisation objectives for patients receiving radiotherapy for mediastinal lymphomas to determine to what extent breast dose could be minimised.
Competing interests
The authors declare none.
Appendix
Appendix 1 shows all the data for the left breast for all patients
Appendix 2 shows all the data for the right breast for all patients
Appendix 3 shows all the data for the combined breasts for all patients