A systemwide approach to validation of electronic device denominator data

Published online by Cambridge University Press:  07 October 2022

Kristen E. Metzger*
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois Analytics Department, Northwestern Medicine, Chicago, Illinois
Asra A. Salim
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois Analytics Department, Northwestern Medicine, Chicago, Illinois
Anessa R. Mikolajczak
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois
Gina Dolgin
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois
Grace M. Barajas
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois
Charles R. Jenkins
Affiliation:
Analytics Department, Northwestern Medicine, Chicago, Illinois
Christina M. Silkaitis
Affiliation:
Department of Healthcare Epidemiology and Infection Prevention, Northwestern Medicine, Chicago, Illinois
*
Author for correspondence: Kristen E. Metzger, MPH, CIC, FAPIC, E-mail: kristen.metzger@stjoeshealth.org
Rights & Permissions [Opens in a new window]

Abstract

A multidisciplinary team collaborated to develop and validate a process to electronically capture patient and device denominator data at 6 hospitals in the same healthcare system. Validation was completed within 4–16 months. Manual count errors were identified as the main driver of electronic versus manual discrepancies.

Type
Concise Communication
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

Accurately capturing patient, central-line, indwelling urinary catheter, and ventilator denominator data is essential for calculation of healthcare-associated infection (HAI) metrics. National Healthcare Safety Network (NHSN) denominator data collection methods include manual daily capture, manual weekly sampling, and electronic capture. 14 Manual data collection is burdensome, leaving less time for essential healthcare duties. Wright et al Reference Wright, Fisher, John, Reynolds, Peterson and Robicsek5 established that accurate automation of device data was achievable, and others have reported on the importance of validation. Reference Tejedor, Garrett and Jacob7,Reference Backman, Nobert, Melchreit, Fekieta and Dembry8 To use electronically captured denominator data, the NHSN requires that it is validated to match manual data within 5% for 3 consecutive months. 1 Validation is required when facilities first implement electronic capture and when transitioning from one electronic method to another. 1 Denominator validation is an operationally challenging task that healthcare facilities often struggle to successfully accomplish.

At our expanding health system, validation of electronic denominator data was previously completed at each hospital using disparate approaches and electronic health record (EHR) systems. The process was inefficient, unstandardized, and fraught with challenges. However, a planned integration of all hospitals into the same EHR necessitated revalidation. The goal of this project was to apply knowledge gained from past challenges to develop a standardized, systemwide, scalable approach to electronic denominator data validation.

Methods

In March 2018, 6 hospitals (5 acute-care hospitals and 1 critical-access hospital) in a large Illinois health system integrated onto 1 EHR platform and infection control module (Epic, Verona, WI), rendering past methods of electronic data capture nonfunctional. Consequently, infection prevention and analytics teams collaborated to develop and validate a new electronic data-capture process (Fig. 1).

Fig. 1. Overview of the process for the validation of electronic patient and device denominator data, indicating who was responsible for each item. Note. IP, infection prevention.

The analytics team developed custom structured query language (SQL) code to run daily at 11:59 p.m., to extract EHR data and store it in a database. The query was standardized at all hospitals; it adhered to NHSN specifications 14,6 and it used EHR flowsheet data to capture device information (device type, insertion and removal data, first and last assessment date and time). All facilities had the same documentation standards, but logic was designed to best approximate device presence despite imperfect nursing documentation (eg, if device removal date/time was missing, value was imputed based on other available data).

The infection prevention team established a new manual data collection process, created educational materials, and trained designated nursing staff on accurate data collection, using NHSN definitions. 14,6 The staff printed a time-stamped census list from the EHR each night (∼11:59 p.m.) and indicated device(s) present next to each patient name. Infection preventionists retrieved completed lists weekly, then entered the data into a form on a shared website (SharePoint, Microsoft, Redman, WA). Infection preventionists at all hospitals could simultaneously enter data, and dropdown selections ensured consistency in naming and formatting conventions.

The analytics team then developed a process to extract manual data from the shared website and then incorporate it into the same database storing electronic denominator data. An automated report (Appendix online) accessed through an internal web portal summarized validation results and allowed users to view detail-level electronic data (eg, list of patients and devices by date). If manual data were missing for a particular nursing unit and date, electronic data for that unit and date were also excluded from comparisons.

When denominator counts did not match within 5%, infection preventionists compared electronic and manual detail-level data then performed chart review (EHR flowsheets, notes, radiology reports) to investigate discrepancies and ascertain device presence. Data were collected on a sample of discrepant charts and were recorded on the shared website. Documentation of discrepancies was not mandatory, but it served as a helpful tool to gain insight, provide feedback, and drive improvement. If programmatic issues were identified, the analytics team altered the query. When there was indisputable evidence from multiple sources in the EHR that a manual count was incorrect, it was corrected, and then was reflected in the validation report upon subsequent data extraction.

Manual counts from the validation report were used for monthly reporting to the NHSN and were adjusted to account for missing data according to NHSN guidelines. 6 Once a unit completed validation, staff stopped manual data collection and transitioned to electronic denominator reporting.

Results

Validation of electronic denominator data was completed at all 6 hospitals, within 4–16 months (Table 1). Among 67 participating nursing units, 40 (59.7%) completed validation in 4 months, 10 (14.9%) in 5–8 months, and 17 (25.4%) in ≥9 months.

Table 1. Denominator Validation Results by Hospital

Note. EHR, electronic health record.

a Inpatient nursing units and licensed beds, as of March 2018.

b Epic software (Verona, WI).

Among a sample of 639 manual versus electronic count discrepancies recorded at 4 hospitals, the following reasons were noted (categories not mutually exclusive): 486 manual count errors (76.1%), 140 nursing documentation deficiencies (21.9%) (ie, inaccurate or missing device removal date and time, missing assessments, missing documentation of nonaccessed central lines), 33 electronic report issues (5.2%) (ie, patient inclusion criteria, missing device types), and 14 other (2.2%). Among 486 manual count errors identified, common reasons included omitting nonaccessed ports or long-term central venous catheters; omitting ventilators; inappropriately counting excluded devices (ie, midline catheters, peripheral intravenous devices, intra-aortic balloon pumps, suprapubic catheters, condom catheters or ureteral stents); and capturing manual counts well outside the recommended 11:59 p.m. count time.

Discussion

Our systemwide approach to electronic denominator validation streamlined data collection and reporting to improve efficiency. With dedicated analytics support and automated tools, validation was completed at all hospitals with various timelines. Specific factors that affected time to completion included prior experience documenting in Epic software, facility size, device prevalence (ie, difficulty matching within 5% with small numbers), and the amount of time infection preventionists dedicated to discrepancy review on assigned units. Devoting time to regularly review discrepancies and provide feedback to nursing early in the process were essential to completing validation and saving future time and effort.

Manual counting errors accounted for >70% of the discrepancies identified. Infection preventionists provided feedback and re-education on data manual collection, and they corrected data when there was clear evidence of errors. The high prevalence of manual count errors calls into question whether manual counts should be considered the source of truth in device data capture. Although validation is essential to ensuring data accuracy, manual data are imperfect, prone to human error, and rely on continual education to maintain accuracy. Additionally, in our situation of revalidation due to a transition between electronic methods, staff may have benefitted from extra time to adjust to documenting in a new EHR and collecting manual data before initiating validation efforts.

We chose to develop a custom method of capturing electronic denominator data due to limitations noted in vendor solutions at the time of project initiation. In particular, the vendor’s electronic capture method lacked flexibility to account for incomplete documentation, and changing predefined logic was difficult or impossible. Although monthly aggregated electronic data were readily available in an EHR report, we could not easily obtain and store detail-level electronic data to compare with manual data stored outside the EHR system. Moving forward, EHR and IP software vendors have the opportunity to further advance capability to facilitate validation of electronic data validation.

With advancing technology, expanding health systems, and increasing need to reduce burden on underresourced teams, supporting efforts to efficiently validate and implement electronic denominator data is crucial. Accurate denominator data are not only necessary for correct calculation of NHSN infection metrics for each individual hospital, but they also have a collective impact on national and state benchmarks. This report has summarized a multidisciplinary approach to successfully scale and optimize electronic denominator data validation across a large healthcare system.

Supplementary material

To view supplementary material for this article, please visit https://doi.org/10.1017/ice.2022.130

Acknowledgments

We thank all infection prevention, nursing and analytics staff who contributed to denominator validation efforts.

Financial support

No financial support was provided relevant to this article.

Conflicts of interest

All authors report no conflicts of interest relevant to this article.

Footnotes

(Present affiliation: Infection Prevention and Control Services, Trinity Health St. Joseph Mercy, Ann Arbor, Michigan [K.M.]).

PREVIOUS PRESENTATION: These data were presented in part in abstract 2401at the Association of Professionals in Infection Control and Epidemiology 2019 Annual Conference on June 13, 2019, in Philadelphia, Pennsylvania.

References

National Healthcare Safety Network (NHSN) patient safety component manual. Centers for Disease Control and Prevention website. https://www.cdc.gov/nhsn/pdfs/pscmanual/pcsmanual_current.pdf. Published January 2021. Accessed October 4, 2021.Google Scholar
Instructions for completion of denominators for intensive care unit (ICU)/other locations (not NICU or SCA) (CDC 57.118). Centers for Disease Control and Prevention website. https://www.cdc.gov/nhsn/forms/instr/57_118.pdf. Published January 2021. Accessed October 4, 2021.Google Scholar
Instructions for completion of denominators for specialty care area (SCA)/Oncology (ONC) (CDC 57.117). Centers for Disease Control and Prevention website. https://www.cdc.gov/nhsn/forms/instr/57_117.pdf. Published January 2021. Accessed October 4, 2021.Google Scholar
Instructions for completion of denominators for neonatal intensive care unit (NICU) (CDC 57.116). Centers for Disease Control and Prevention website. https://www.cdc.gov/nhsn/forms/instr/57_116.pdf. Published January 2021. Accessed October 4, 2021.Google Scholar
Wright, MO, Fisher, A, John, M, Reynolds, K, Peterson, LR, Robicsek, A. The electronic medical record as a tool for infection surveillance: successful automation of device days. Am J Infect Control 2009;37:364370.10.1016/j.ajic.2008.11.003CrossRefGoogle ScholarPubMed
NHSN guidance for missing device-associated denominator data. Centers for Disease Control and Prevention website. https://www.cdc.gov/nhsn/PDFs/NHSNMissingDenomData_Sep2013.pdf. Published September 2013. Accessed October 4, 2021.Google Scholar
Tejedor, SC, Garrett, G, Jacob, JT, et al. Electronic documentation of central venous catheter–days: validation is essential. Infect Control Hosp Epidemiol 2013;34:900907.10.1017/S0195941700033695CrossRefGoogle ScholarPubMed
Backman, LA, Nobert, G, Melchreit, R, Fekieta, R, Dembry, LM. Validation of the surveillance and reporting of central-line–associated bloodstream infection denominator data. Am J Infect Control 2014;42:2833.10.1016/j.ajic.2013.06.014CrossRefGoogle ScholarPubMed
Snyders, R, Babcock, H. Validating electronically collected denominator data: getting to the elusive ±5%. Am J Infect Control 2016;44:S55.10.1016/j.ajic.2016.04.055CrossRefGoogle Scholar
Boyce, JM, Paci, J, Feidner, C, Hubbard, L. Prospective validation of central-line days derived from an electronic medical record system. Infect Control Hosp Epidemiol 2015;36:10981099.10.1017/ice.2015.137CrossRefGoogle ScholarPubMed
Figure 0

Fig. 1. Overview of the process for the validation of electronic patient and device denominator data, indicating who was responsible for each item. Note. IP, infection prevention.

Figure 1

Table 1. Denominator Validation Results by Hospital

Supplementary material: File