Introduction
Passive exoskeletons use the biomechanics of human motion to improve the efficiency of performing the tasks (Carrozza et al., Reference Carrozza, Silvestro, Jos, Symposium, Robotics, Accoto, Agrawal, Babiloni, Carmena, Carrozza, Dario, Forner-Cordero, Fujie, Garcia, Hogan, Krebs, Lefeber, Munih, Rossini, Takanishi, Taylor, Weitz and Zollo2017). The advantage of passive wearables is their low profile, allowing their use in everyday life without inconveniencing the user (Carrozza et al., Reference Carrozza, Silvestro, Jos, Symposium, Robotics, Accoto, Agrawal, Babiloni, Carmena, Carrozza, Dario, Forner-Cordero, Fujie, Garcia, Hogan, Krebs, Lefeber, Munih, Rossini, Takanishi, Taylor, Weitz and Zollo2017). These characteristics suit industrial environments where reducing effort and joint effort is desirable, especially in lifting tasks. The knee joint power and moment profiles of a lifting task, characterized by Hwang et al. (Reference Hwang, Kim and Kim2009), show distinct phases of work done on (or by) the knee joint, as seen in Figure 1. Commercial passive exoskeletons typically assist in maintaining specific postures for extended amounts of time, such as the Chairless Chair (Noone, Deizisau, Germany) for long-standing tasks, the ShoulderX (US Bionics, Berkeley, CA), the Paexo (Ottobock, Duderstadt, Germany) for raised arm tasks, and the ZeroG (Eksobionics, Richmond, VA) for tool carrying. These exoskeletons provide support in a static position but cannot support the dynamic task of lifting during squatting. This task requires several muscles to stabilize the body, as shown by Escamilla et al. (Reference Escamilla, Fleisig, Lowry, Barrentine and Andrews2001). The body is stabilized in the dynamic squatting task by the vastus lateralis, vastus medialis, and gluteus maximus, and extending the knee in ascent recruits the rectus femoris and biceps femoris muscles to provide strength for lifting.
In the literature, Van Dijk et al. (Reference Van Dijk, Van Der Kooij and Hekman2011) proposed the design methodology of using the phase of a task where energy is stored when work is done on a joint and energy is returned when work is done by a joint. This was the methodology used by the passive knee-ankle exoskeleton targeting the storage and return of energy during distinct phases of the gait cycle by Etenzi et al. (Reference Etenzi, Borzuola and Grabowski2020). The mechanics and energetics of gait using unpowered ankle exoskeletons were characterized by Sawicki and Ferris (Reference Sawicki and Ferris2008), and this characterization informs designs of ankle exoskeletons for further studies in the literature. The ankle designs have targeted optimal stiffness for metabolic cost reduction in gait and running, as shown by the work of Collins et al. (Reference Collins, Bruce Wiggin and Sawicki2015) and Nasiri et al. (Reference Nasiri, Ahmadi and Ahmadabadi2018). Witte et al. (Reference Witte, Fiers, Sheets-Singer and Collins2020) proposed a powered and unpowered exoskeleton and studied the effects on human running. Passive ankle exoskeletons have been designed with the goal of widespread adoption (Yandell et al., Reference Yandell, Tacca and Zelik2019).
Other passive lower limb exoskeletons focus on the hip joint and target net energetic decreases during walking by the use of an elastic band (Haufe et al., Reference Haufe, Wolf, Riener and Grimmer2020), maintaining balance while walking (Zhang et al., Reference Zhang, Tran and Huang2018), and increasing walking distance for neurological patients (Panizzolo et al., Reference Panizzolo, Cimino, Pettenello, Belfiore, Petrone and Marcolin2021).
An industrial worker typically lifts a load while stooping or performing a squat, with the latter being preferable as it recruits more muscles from the lower limbs (Hwang et al., Reference Hwang, Kim and Kim2009). In this paper, we focus on squatting. During squat ascent, the rectus femoris acts as a biarticular hip flexor and knee extensor. These effects are more pronounced when the trunk is upright, as noted by Escamilla (Reference Escamilla2001). The stance and placement of the feet in a squat do not affect activations of muscles at the knee (Escamilla, Reference Escamilla2001) but affect the knee kinetics, as shown by Almosnino et al. (Reference Almosnino, Kingston and Graham2013) and Lorenzetti et al. (Reference Lorenzetti, Ostermann, Zeidler, Zimmer, Jentsch, List, Taylor and Schellenberg2018). Ideally, a device that aids in reducing muscle activation should not significantly affect the user’s preferred stance and foot loading profiles.
We propose a passive, unpowered exoskeleton SpringExo to assist knee extension and reduce the rectus femoris activation during ascent in a squatting task. The SpringExo design (Figure 2) uses the power profile shown in Figure 1 to store energy in descent and returns it during ascent. The SpringExo can store elastic energy while the user descends. If the spring can contribute to the joint torque in ascent, we can expect less effort expended by the user and decrease muscle activation in ascent. We investigate whether this effect is present with a SpringExo worn around each leg with seven healthy subjects in this paper. We use the methodology proposed by Van Dijk et al. (Reference Van Dijk, Van Der Kooij and Hekman2011) to explore the feasibility of decreasing the rectus femoris activation in a squatting task. This paper aims to characterize the change in muscle activation, mainly focusing on the rectus femoris as the knee extensor that is activated during ascent, as found by Escamilla et al. (Reference Escamilla, Fleisig, Lowry, Barrentine and Andrews2001) during squats. The rectus femoris is also the primary muscle activity decrease targeted during squat lifting, such as the motorized quasi-passive device in Yu et al. (Reference Yu, Huang, Wang, Lynn, Sayd, Silivanov, Park, Tian and Su2019) and the entirely passive torsional spring design in Ranaweera et al. (Reference Ranaweera, Gopura, Jayawardena and Mann2018).
The SpringExo is an entirely passive system that targets knee extension while remaining low profile to wear under a user’s clothing. It does not require a motor, unlike the device presented in Yu et al. (Reference Yu, Huang, Wang, Lynn, Sayd, Silivanov, Park, Tian and Su2019), and requires fewer components than the passive exoskeleton in Ranaweera et al. (Reference Ranaweera, Gopura, Jayawardena and Mann2018). The simplicity of the design and incorporating the spring elements into the architecture itself are the main features that make the SpringExo a novel wearable device, similar to the ankle exoskeleton presented in Yandell et al. (Reference Yandell, Tacca and Zelik2019).
We test whether the SpringExo reduces rectus femoris activation in a squatting task and characterize the effects on the user’s squat biomechanics. Primary measures include the timing, knee flexion angles, and the rectus femoris and biceps femoris muscle activations. In addition, we also verify that our device does not affect the user’s foot loading preference by looking at the exoskeleton’s effect on the distance between pressure maximums at the ball and heel of each user’s feet and the total pressure loading line lengths on the right and left feet.
Methodology
Design of SpringExo
The passive SpringExo in Figure 2 is a 3D-printed nylon spring coil attached to a photopolymer resin 3D-printed thigh cuff and shank cuff, which can strap to the thigh and shank of the user. The coil spring can accommodate extreme knee flexion in squat kinematics, such as in Tewart (Reference Tewart2012). The cuffs are mechanically connected to the spring ends and attached to the leg via Velcro straps covering the skin to avoid discomfort. The coils do not collide when a user performs a squat as they both revolve in the same direction. The complete assembly weighs 450 g. The exoskeleton is easily donned and doffed while securing the leg. A user wearing the SpringExo is shown in Figure 3. The parts and instrumented treadmill used in this study are labeled.
The SpringExo only assists in knee extension during the ascent part of the squat cycle while the energy is stored during descent. The spring bending angle $ \varphi $ compresses the spring and results in the Force $ {F}_s $ acting on the thigh. The angle $ \varphi $ is the central spring angle defined as:
The spring exerts a force $ {F}_s $ on the leg due to the bending arc of the spring. The net force is composed of a tangential component $ {F}_{sT} $ that supports the leg, and a normal component $ {F}_{sN} $ that provides assistance in leg extension, as shown in Figure 2.
The Spring mechanism and stored potential energy of this device is described in Sui et al. (Reference Sui, Chang, Hidayah, Zhu and Agrawal2021). We briefly present this mechanism here. The total elastic potential energy $ {E}_{\mathrm{p}} $ stored in the spring comes from compression $ {E}_{\mathrm{c}} $ and bending $ {E}_{\mathrm{b}}. $
In compression, the virtual center length of the spring changes from its free length $ {l}_{\mathrm{s}} $ to the arc length $ \overset{\frown }{l} $ , and the elastic potential energy $ {E}_{\mathrm{c}} $ stored in the spring with a stiffness of $ k $ is:
In bending, according to Kim et al. (Reference Kim, Cheng, Diakite, Gullapalli, Simard and Desai2017), Gutkowski (Reference Gutkowski1998), and Wahl (Reference Wahl1963), the total stored potential energy $ {E}_{\mathrm{b}} $ due to the spring bending with a constant arc length $ \overset{\frown }{l} $ is expressed as:
where $ \beta $ , $ E $ , $ I $ , $ G $ , $ {r}_{\mathrm{c}} $ , $ n $ , and $ \mathrm{d}s $ are, respectively, the flexural rigidity of the spring, Young’s modulus, area moment of inertia, shear modulus, mean radius of the spring coil, number of the spring coil, and element of the arc length $ \overset{\frown }{l} $ . According to equations (4)–(7), $ \mathrm{d}s=R\mathrm{d}\varphi $ , and the geometric relationship in Figure 2a, the total stored elastic potential energy $ {E}_{\mathrm{p}} $ is expressed as:
The SpringExo has an outer diameter $ D $ = 167 mm, a coil diameter of $ d $ = 16.5 mm. Nylon-66’s has a Flexural Modulus $ \beta $ of 2,700 Nmm−2, and Young’s modulus $ E $ of 3.7 Gpa. The analysis and optimization of these parameters for SpringExo stiffness are not included in this work.
Subjects
A convenience sample of seven healthy subjects (four females)—age 25.9 ± 2.2 years, height 167.6 cm ± 4.6 cm, and mass 54.3 kg ± 5.8 kg—were recruited to carry out the study. Investigators collected informed consent from subjects in the study approved by the Institutional Review Board of Columbia University.
Experimental Setup and Protocol
Subjects performed squatting motions on an instrumented treadmill (Pluto, HP Cosmos, Nußdorf, Germany) with an integrated pressure sensor to measure foot pressure at a frequency of 100 Hz. Markers were placed on the distal phalanges, ankle, heel, tibia, knee, femur, and trochanter to capture knee motion data at 200 Hz (Vero, Vicon, Oxford, United Kingdom). Wireless EMGs were placed on the rectus femoris and bicep femoris muscles. These data were captured at 2,000 Hz (Trigno, Delsys, Cambridge, MA) in the marked positions shown in Figure 3.
A baseline (B) condition where the subjects performed squats wearing no device was compared against the condition where the SpringExo exoskeleton was worn (E). Subjects completed squat cycles at their own pace in each condition. Subjects were assigned either the B or E condition in a random order. Each measurement started and ended with the subjects standing neutrally and at rest. Subjects did not acclimatize to the springs by practicing with the design and performed the squats directly after donning the device. Investigators instructed subjects to squat continuously until tired. The first five squat cycles were discarded. The next 20 cycles from each subject were analyzed and interpreted.
Data Processing
All data preparation and processing was done using Python 3.6 (Python, Wilmington, DE). Kinematics of the knee joint was solved using the marker set on the leg. Markers attached to the hip were used to segment each squat cycle, where the upright position was used as an endpoint. Each segment’s EMG data and joint angles from both legs were normalized into a cycle, where 0% indicates the initial standing position, 25% indicated halfway through descent, 50% indicates the lowest position, 75% indicates halfway through ascent, and 100% indicates the terminal standing position. A fourth-order band-pass (20–400 Hz) Butterworth filter was used to filter the raw EMG signals, rectified and passed through another fourth-order low-pass (3 Hz) Butterworth filter. Each subject’s cycles were B-normalized using the subject’s maximum muscle activation values in B sessions.
Each subject’s EMG signals were normalized by their respective B maximum values. All subjects’ knee flexion angles, normalized rectus femoris (nRF), and normalized bicep femoris profiles were averaged across both legs. These profiles were used to calculate averages, maxima, and the descent and ascent values for each parameter. The knee kinematics and muscle activations of each mode compare the effect of the worn SpringExo on user biomechanics during a squat exercise.
The foot pressure maximum at the ball and the heel of the foot were found for each cycle. The loading line length and stance width of the feet were also extracted across the same cycles. Differences in these parameters between the two conditions indicate the effects of wearing the SpringExo on the user’s overall foot placement patterns. Differences in overall foot loading and placement indicate changes that can adversely affect the person’s safety and comfort in performing the squatting task.
Statistical Analysis
The mean values, maximum values, minimum values, values at 25% and 75% of the squat cycle, and their standard deviations to the mean were calculated for knee flexion, muscle activations, and foot loading parameters. Each cycle’s values for each subject were grouped according to the mode B or E. The data were tested for normality using Kolmogorov–Smirnov one-sample tests. The data violated normality, and so nonparametric tests were selected to compare the conditions. A Mann–Whitney U test was used to compare the values reported in this paper. Significance was set at $ \alpha =0.05. $
Results
Figure 4 shows the changes in the subjects’ squat cycle timing, knee flexion profiles, and muscle activation due to the B or E mode. We summarize the observations qualitatively here with values reported further in this section—an increase in overall squat cycles’ timing is observed. The maximum flexion angle of the knee is smaller when wearing the exoskeleton when compared to the baseline. The rectus femoris muscle activity is lower, particularly in the ascent phase of the squat.
Figure 5 shows timing, knee flexion, and muscle activity averages, maximums, and the descent (25%) and ascent (75%) points of the squat cycle. Figure 6 shows the effects of wearing the passive exoskeleton on specific intervals of the squat cycle across all subjects and exoskeleton modes.
The differences are characterized and compared statistically in Figure 5. Significant differences from B to E are summarized in Figure 5 with p-values reported. We see an increase in squat cycle timing overall between B and E (Avg: $ +0.02s $ , Max: $ +0.10s $ , $ 25\% $ : $ +0.01s $ , $ 75\% $ : $ +0.1s $ ). We see a decrease in nRF activation in ascent between B and E ( $ 75\% $ : $ -2\% $ ). No statistically significant difference is observed in the activation of bicep femoris during the gait cycle. An overall decrease in knee flexion angles is observed (Avg: $ -4{}^{\circ} $ , Max: $ -12{}^{\circ} $ , $ 75\% $ : $ -9{}^{\circ} $ ).
Figure 6 shows the effects of wearing the exoskeleton on the foot loading parameters across all subjects in both modes. Figure 6b defines the foot loading parameters discussed in this paper. There were no significant differences observed between B and E modes for the ball–ball or heel–heel distances of the feet. No significant difference was observed for the loading lines of the left or right foot either. No other significant changes were observed. The subjects have a smaller range of foot loading parameters in E, except for loading on the right leg, which increases in range, as shown in Figure 6a. The statistical analysis yielded marginal p-values for ball–ball distance ( $ p=.052 $ ). The ball–ball distance increased slightly on average ( $ +1.3 $ cm), which indicates that frontal foot pressure moved away from the midline. More subjects are required to verify a conclusive effect of wearing the SpringExo device.
Discussion
The SpringExo was able to significantly decrease RF activation during ascent, roughly at 75% of the squat cycle. The device did not significantly increase muscle activation in any other phase of the cycle. The device did not affect the BF muscle activity. The decrease in muscle activation indicates that a simple coil spring architecture is a suitable ergonomic choice in this specific movement in an industrial context, where muscle activity reduction is desirable. Other user effects include a longer squat cycle time, indicating that the device affected the user’s chosen velocity for performing a squat task. A significant decrease in knee flexion angle was seen.
The restriction of the knee angle is a limitation that must be addressed by testing different spring stiffness that produces a reduction in EMG values while still retaining the same range of motion of flexion in the knee at the halfway point of the squat cycle. This can be done by following the methodology for empirically testing for optimal spring stiffness and the effects on EMG activation in a study similar to the one done in Collins et al. (Reference Collins, Bruce Wiggin and Sawicki2015). An optimal spring stiffness for a specific cohort of users can then be determined by having users complete the same squatting task with the same knee flexion magnitudes and evaluating the muscle activation decrease. Furthermore, the increase in the timing of performing the squat task could contribute to the lower muscle activation of the rectus femoris, as the velocity of doing a squat has an effect on the activation and recruitment of muscle groups in the quadriceps as characterized by Stasinaki et al. (Reference Stasinaki, Zaras, Methenitis, Bogdanis and Terzis2019). Our study aimed to characterize the effect on the primary muscle that aids in knee extension, and effects on the stabilizing muscles of gluteus maximus, vastus lateralis, and vastus medialis were not investigated. This is a potential area of investigation for a study that fully characterizes the effect of SpringExo in a study looking at loaded lifts, the effect of spring stiffness, or adding a motor.
The foot loading parameters show that donning the SpringExo did not significantly change the users’ stance. Foot placement in a dynamic squat task can significantly change the person’s lower limb kinetics performing the task (Almosnino et al., Reference Almosnino, Kingston and Graham2013). For example, Demers et al. (Reference Demers, Pendenza, Radevich and Preuss2018) showed that narrower stances in squats could indicate larger hip adduction torques. The foot loading parameters do not significantly change with the worn device. This lack of change implies that the device does not impede or interfere with the user’s foot loading preferences while squatting. This points to this device’s suitability in an industrial workspace, as it would not interfere with comfort or preferences of a user while descending and ascending from a bodyweight squat. It is a limitation of this study that a loaded lifting task was not considered, as the foot loading preferences after picking up a load would be more informative for the real-world application with this device. We can expand the device’s capabilities to target assistive lifting tasks such as in Yu et al. (Reference Yu, Huang, Wang, Lynn, Sayd, Silivanov, Park, Tian and Su2019), where the motor’s torque magnitude was used to reduce RF activation to different levels. Hwang et al. (Reference Hwang, Kim and Kim2009) characterized the magnitude of the power required for squat ascent at the knee, which can be used to select an appropriate motor to compensate for part or most of the biological energy necessary for the lifting task.
Future investigations that can be carried out with this device include the exploration of motorizing this system such that a quasi-passive mode can be used to aid in descent and release the stored energy in ascent. The SpringExo would ideally be used on its own in a passive mode to reduce parts and complexity, and as-needed can be motorized to optimize performance, as shown in Sui et al. (Reference Sui, Chang, Hidayah, Zhu and Agrawal2021).
Conclusion
We designed a passive exoskeleton that targeted storing elastic energy during squat descent and returning this energy to the squat ascent phase. The spring exoskeleton reduced muscle activation in the rectus femoris during ascent in the squat cycle without increasing bicep femoris activation. The knee flexion angle decreased overall but without significant changes in foot loading and placement parameters. Future investigation into different spring stiffness or a motor to aid in descent is required to optimize utility from this simple and easily wearable device.
Acknowledgment
We are grateful for the participation of all subjects in this study.
Funding Statement
This work was supported by NYS research funding DOH01-C31290GG and NSF grant IIS-1339666. Dongbao Sui was supported by research funding from the China Scholarship Council (CSC) for his joint Ph.D. project (No. 201806120118).
Competing Interests
The authors declare no competing interests exist.
Authorship Contributions
Experimentation, R.H., D.S., and B.-C.C.; Data processing, R.H. and K.A.W.; Data visualization, R.H.; Original draft: R.H. and S.K.A.; All authors approved the final submitted draft.
Data Availability Statement
Data can be made available to interested researchers upon request by email to the corresponding author.
Ethical Standards
The authors assert that all procedures contributing to this work comply with the ethical standards of the Columbia University’s Institutional Review Board standards for human subjects studies.