K-α emission is an intense short-pulse line source well
suited for X-ray diagnostic techniques with subpicosecond and
micrometer resolution. Numerical simulations are performed here in a
search for laser–target interaction regimes where both high
efficiency of laser energy transformation to X-ray emission and
ultrashort X-ray pulses are achieved. We use the one-dimensional PIC
code for the description of the laser interaction with the plasma layer
at the target surface. Fast electron transport into the target is
treated by our newly developed Monte Carlo code with temporal
resolution that is described here in detail. Our simulations reveal
extremely short ∼200 fs FWHM bright K-α X-ray pulses
emitted from targets heated by 120-fs pulses of a table-top laser.
Laser energy conversion efficiency to K-α line emission as
high as 6 × 10−5 is noticed. Integration of the
emitted energy over the focal spot is carried out to improve the
simulation accord with published experimental data. Negligible impact
of self-induced electric fields on K-α emission is found
for conducting target materials at moderate laser intensities
[lsim ]1017 W/cm2.