We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Few studies claimed that dynamic jaw (DJ) mode in Helical TomoTherapy® (HT) could improve the cranio-caudal dose distribution without prolonging the treatment time in treating different types of cancer. Also, studies suggested that DJ with a wider 5 cm field width (FW) could replace fixed jaws (FJ) with 2.5 cm FW to reduce the delivery time with the sustainable plan quality. Yet, the study on breast cancer with supraclavicular fossa (SCF) nodal involvement using DJ mode in HT is limited. This study aims to evaluate the DJ mode retrospectively by comparing their dosimetric quality with normal tissue complication probability (NTCP) of organs at risk and treatment delivery time with FJ mode on treating left-side breast with SCF nodal involvement.
Materials and methods:
All post-mastectomy patients, who had been irradiated for left-side breast with SCF nodal involvement were selected retrospectively in this study. With the same dose constraint and prescription as the treated DJ2.5 plan, two extra plans using DJ mode with 5 cm FW(DJ5.0) and FJ mode with 2.5 cm FW (FJ2.5) were computed for plan comparison.
Results:
No statistical significance was found in all the parameters of PTV and OARs, except for V20 of whole lung. DJ5.0 received V20 in ipsilateral left lung than FJ2.5 and DJ2.5. However, the average delivery time of DJ5.0 was significantly lower than that of DJ2.5 and FJ2.5 by almost 40%.
Conclusions:
No statistical significance was found in those dosimetric and radiobiological parameters among three modes while the delivery time has greatly reduced by using DJ5.0. A shorter treatment time can minimise intra-fractional error and better the patient’s experience during treatment.