Skip to main content Accessibility help
×
Hostname: page-component-78c5997874-s2hrs Total loading time: 0 Render date: 2024-11-10T12:58:05.405Z Has data issue: false hasContentIssue false

8 - Hemorheology

Published online by Cambridge University Press:  07 April 2021

Norman J. Wagner
Affiliation:
University of Delaware
Jan Mewis
Affiliation:
KU Leuven, Belgium
Get access

Summary

Blood is a concentrated suspension of deformable, aggregating, red blood cells within a medium of other cells and proteins. It is a complex colloidal system with a non-Newtonian rheology that is characterized by viscoplasticity, thixotropy, and viscoelasticity. After reviewing some of the key biological characteristics of human blood, and after presenting a short historical review of the subject, we present some recent accomplishments. These range from the development of a parameterized Casson model, based on the hematocrit and fibrinogen levels, to the discussion of several recent structural models that are able to capture several of the time-dependent rheological effects of blood. A comparison is also offered between model predictions and the results of recent transient measurements, some involving a newly proposed variant of LAOS: the Unidirectional LAOS. The latter experiment is especially appropriate for the study of blood rheology as it follows roughly the flow experienced by blood in the arterial circulation. It consists of a superposition of steady and large amplitude oscillatory flow in such a way that flow reversal is avoided. Some additional models are discussed along with the challenges and opportunities for future research.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 2021

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

GBD 2016, Causes of Death Collaborators, regional, and national age-sex specific mortality for 264 causes of death, 1980–2016: A systematic analysis for the Global Burden of Disease Study 2016. Lancet. 2017;390(10100):11511210.Google Scholar
American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee, Heart Disease and Stroke Statistics – 2018 Update: A Report from the American Heart Association. Circulation. 2018;137(12):e64–e492.Google Scholar
Pedley, T. The Fluid Mechanics of Large Blood Vessels. Cambridge: Cambridge University Press; 1980.Google Scholar
Cheer, AY, van Dam, CP. (eds.) Fluid Dynamics in Biology. Contemporary Mathematics, vol. 141, Providence, RI: American Mathematical Society; 1993.CrossRefGoogle Scholar
Fung, YC. Biomechanics. Circulation, 2nd ed. New York: Springer-Verlag; 1997.Google Scholar
Drzewiecki, GM, Li, JK-J. Analysis and Assessment of Cardiovascular Function. New York: Springer-Verlag; 1998.Google Scholar
Li, JK-J. The Arterial Circulation. Physical Principles and Clinical Applications. Totowa, NJ: Humana Press; 2000.Google Scholar
Li, JK-J. Dynamics of the Vascular System (Series on Bioengineering and Biomedical Engineering – Vol. 1). Singapore: World Scientific; 2004.Google Scholar
Zamir, M. The Physics of Pulsatile Flow. New York: AIP Press, Springer-Verlag; 2000.CrossRefGoogle Scholar
Zamir, M. The Physics of Coronary Blood Flow. New York: AIP Press, Springer-Verlag; 2005.Google Scholar
Kowalewski, TA. (ed.) Blood Flow Modelling and Diagnostics. Warsaw, Poland: Institute of Fundamental Technological Research; 2005.Google Scholar
Waite, L, Fine, J. Applied Biofluid Mechanics. New York: McGraw Hill; 2007.Google Scholar
Batzel, JJ, Kappel, F, Schneditz, T, Tran, HT. Cardiovascular and Respiratory Systems. Modeling, Analysis, and Control. Philadelphia, PA: SIAM; 2007.Google Scholar
Galdi, GP, Rannacher, R, Robertson, AM, Turek, S. (eds.) Hemodynamical Flows. Modeling, Analysis and Simulation. Basel, Switzerland: Birkhäuser; 2008.Google Scholar
Thiriet, M. Biology and Mechanics of Blood Flows, 2 vols. New York: Springer; 2008.Google Scholar
Truskey, GA, Yuan, F, Katz, DF. Transport Phenomena in Biological Systems, 2nd ed. Upper Saddle River, NJ: Prentice Hall; 2009.Google Scholar
Formaggia, L, Quarteroni, A, Veneziani, A. (eds.) Cardiovascular Mechanics, Vol.1, Modeling and Simulation of the Circulatory System. Milano, Italy: Springer-Verlag; 2009.Google Scholar
Nichols, WW, O’Rourke, MF, Vlachopoulos, C. McDonald’s Blood Flow in Arteries. Theoretical, Experimental and Clinical Principles, 6th ed. London: Hodder Arnold; 2011.Google Scholar
Chandran, KB, Rittgers, SE, Yoganathan, AP. Biofluid Mechanics. The Human Circulation, 2nd ed. Boca Raton, FL: CRC Press; 2012.Google Scholar
Peattie, RA, Fisher, RJ, Bronzino, JD, Peterson, DR. Transport Phenomena in Biomedical Engineering. Principles and Practices. Boca Raton, FL: CRC Press; 2013.Google Scholar
Vander, AJ, Sherman, JH, Luciano, DS. Human Physiology. The Mechanisms of Body Function, 6th ed. New York: McGraw-Hill; 1994.Google Scholar
Chien, S. Biophysical behavior of red cells in suspensions. In Surgenor, DM. (ed.) The Red Blood Cell, 2nd ed., vol. 2. New York: Academic Press; 1975; pp. 10311133.Google Scholar
Ness, PM, Stengle, JM. Historical introduction. In Surgenor, DM. (ed.) The Red Blood Cell, 2nd ed., vol. 1. New York: Academic Press 1974; pp. 150.Google Scholar
Baskurt, OK, Neu, B, Meiselman, HJ. Red Blood Cell Aggregation. Boca Raton, FL: CRC Press; 2012.Google Scholar
Goldsmith, HL, Cokelet, GR, Gaehtgens, P. Fåhræus R. Evolution of his concepts in cardiovascular physiology. American Journal of Physiology. 1989;257(3):H1005H1015.Google Scholar
Fåhræus, R. The suspension stability of blood. Physiological Reviews. 1929;9(2):241274.Google Scholar
Fåhræus, R, Lindqvist, T. The viscosity of blood in narrow capillary tubes. American Journal of Physiology. 1931;96(3):562568.Google Scholar
Stavridis, IK. Contributions of Jean Leonard Marie Poiseuille to microcirculation research (in Greek). In Stavridis, I. K., ed. Graduate Lessons of the Physiology of Microcirculation. Athens, Greece: Medical Publications of P.Ch. Paschalides; 1993, Ch. 1, pp. 917.Google Scholar
Hess, WR. Gehört das Blut dem allgemeinen Strömungsgesetz der Flüssigkeiten? Pflügers Archiv. 1915;162(5):187224.Google Scholar
Casson, N. Rheology of disperse systems. In Mill, CC (ed.) Flow Equation for Pigment Oil Suspensions of the Printing Ink Type. Rheology of Disperse Systems. London: Pergamon Press; 1959; pp. 84102.Google Scholar
Robertson, AM, Sequeira, A, Kameneva, MV. Hemorheology. In Caldi, GP, Rannacher, R, Robertson, AM, Turek, S. (eds.) Hemodynamical Flows. Modelling, Analysis and Simulation, Oberwolfach Seminars, Vol. 37, Basel, Switzerland: Birkhäuser Verlag; 2008, pp. 63120.Google Scholar
Scott Blair, GW. An equation for the flow of blood, plasma and serum through glass capillaries. Nature. 1959;183(4661):613614.Google Scholar
Reiner, M, Scott Blair, GM. The flow of blood through narrow tubes. Nature. 1959;184(4683):354.Google Scholar
Merrill, EW, Cokelet, GC, Britten, A, Wells, RE Jr. Non-Newtonian rheology of human-blood-effect of fibrinogen deduced by “subtraction”. Circulation Research. 1963;13(1):4855.Google Scholar
Cokelet, GC, Merrill, EW, Gilliland, ER, Shin, H. The rheology of human blood – Measurement near and at zero shear rate. Transactions of the Society of Rheology. 1963;7(1):303317.Google Scholar
Merrill, EW, Gilliland, ER, Cokelet, GC, Shin, H, Britten, A, Wells, RE. Rheology of human blood, near and at zero flow: Effects of temperature and hematocrit level. Biophysical Journal. 1963;3(3):199213.CrossRefGoogle ScholarPubMed
Merrill, EW, Gilliland, ER, Lee, TS, Salzman, EW. Blood rheology: Effect of fibrinogen deduced by addition. Circulation Research. 1966;18(4):437446.Google Scholar
Chien, S, Usami, S, Dellenback, RJ, Gregersen, MI. Shear dependence of effective cell volume as a determinant of blood viscosity. Science. 1970;168(3934):977979.Google Scholar
Thurston, GB. Viscoelasticity of human blood. Biophysical Journal. 1972;12(9):12051217.Google Scholar
Sun, N, De Kée, D. Simple shear, hysteresis and yield stress in biofluids. Canadian Journal of Chemical Engineering. 2001;79(1):3641.Google Scholar
Fedosov, DA, Pan, WX, Caswell, B, Gompper, G, Karniadakisb, GE. Predicting human blood viscosity in silico. Proceedings of the National Academy of Sciences of the USA. 2011;108(29):1177211777.Google Scholar
Fedosov, DA, Dao, M, Karniadakis, GE, Suresh, S. Computational biorheology of human blood flow in health and disease. Annals of Biomedical Engineering. 2014;42(2):368387.CrossRefGoogle ScholarPubMed
Rindt, CCM, van Steehoven, AA. Unsteady flow in a rigid 3-D model of the carotid artery bifurcation. Journal of Biomechanical Engineering. 1996;118(1):149159.Google Scholar
Milner, JS, Moore, JA, Rutt, BK, Steinman, DA. Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects. Journal of Vascular Surgery. 1998;28(1):143156.Google Scholar
Gijsen, FJH, van de Vosse, FN, Janssen, JD. The influence of the non-Newtonian properties of blood on the flow in large arteries: Steady flow in a carotid artery bifurcation model. Journal of Biomechanics. 1999;32(6):601608.Google Scholar
Steinman, DA, Thomas, JB, Ladak, HM, Milner, JS, Rutt, BK, Spence, JD. Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI. Magnetic Resonance in Medicine. 2002;47(1):149159.CrossRefGoogle ScholarPubMed
Kato, M, Dote, K, Habara, S, Takemoto, H, Goto, K, Nakaoka, K. Clinical implications of carotid artery remodeling in acute coronary syndrome. Ultrasonographic assessment of positive remodeling. Journal of American College of Cardiology. 2003;42(6):10261032.Google Scholar
Valencia, A, Zarate, A, Galvez, M, Badilla, L. Non-Newtonian blood flow dynamics in a right internal carotid artery with a saccular aneurism. International Journal for Numerical Methods in Fluids. 2006;50(6):751764.Google Scholar
Nguyen, KT, Clark, CD, Chancellor, TJ, Papavassiliou, DV. Carotid geometry effects on blood flow and on risk for vascular disease. Journal of Biomechanics. 2008;41(1):1119.Google Scholar
Gay, M, Zhang, L. Numerical studies of blood flow in healthy, stenosed, and stented carotid arteries. International Journal for Numerical Methods in Fluids. 2009;61(4):453472.Google Scholar
Wake, AK, Oshinski, JN, Tannenbaum, AR, Giddens, DP. Choice of in vivo versus idealized velocity boundary conditions influences physiologically relevant flow patterns in a subject-specific simulation of flow in the human carotid bifurcation. Journal of Biomechanical Engineering. 2009;131(2):021013.Google Scholar
Bevan, RTL, Nithiarasu, P, Van Loon, R, Savonov, I, Luckraz, H, Garnham, A. Application of a locally conservative Galerkin (LCG) method for modelling blood flow through a patient-specific carotid bifurcation. International Journal for Numerical Methods in Fluids. 2010;64(10–12):12741295.Google Scholar
Morbiducci, U, Gallo, D, Massai, D, Ponzini, R, Deriu, MA, Antiga, L, et al. On the importance of blood rheology for bulk flow in hemodynamic models of the carotid bifurcation. Journal of Biomechanics. 2011;44(13):24272438.Google Scholar
Kamenskiy, AV, MacTaggart, JN, Pipinos, II, Bikhchandani, J, Dzenis, YA. Three-dimensional geometry of the human carotid artery. Journal of Biomechanical Engineering – Transactions ASME. 2012;134(6):064502.Google Scholar
Hutchins, GM, Miner, MM, Boitnott, JK. Vessel caliber and branch-angle of human coronary artery branch-points. Circulation Research. 1976;38(6):572576.Google Scholar
Nissen, SE, Gurley, JC, Grines, CL, Booth, DC, McClure, R, Berk, M, et al. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation. 1991;84(3):10871099.Google Scholar
Brinkman, AM, Baker, PB, Newman, WP, Vigorito, R, Friedman, MH. Variability of human coronary artery geometry: An angiographic study of the left anterior descending arteries of 30 autopsy hearts. Annals of Biomedical Engineering. 1994;22(1):3444.Google Scholar
Friedman, MH, Baker, PB, Ding, Z, Kuban, BD. Relationship between the geometry and qualitative morphology of the left anterior descending coronary artery. Arteriosclerosis. 1996;125(12):183192.Google Scholar
Perktold, K, Hofer, M, Rappitsch, G, Loew, M, Kuban, BD, Friedman, MH. Validated computation of physiologic flow in a realistic coronary artery branch. Journal of Biomechanics. 1998;31(3):217228.Google Scholar
Changizi, MA, Cherniak, C. Modeling the large-scale geometry of human coronary arteries. Canadian Journal of Physiology and Pharmacology. 2000;78(8):603611.Google Scholar
Seron, FJ, Garcia, E, del Pico, J. MOTRICO project – geometric construction and mesh generation of blood vessels by means of the fusion of angiograms and IVUS. In: Perales, FJ, Campilho, AJC, de la Blanca, NP, Sanfeliu, A. (eds.) Pattern Recognition and Image Analysis. IbPRIA 2003. Lecture Notes in Computer Science, vol 2652. Berlin: Springer; 2003. https://doi.org/10.1007/978-3-540-44871-6_110.Google Scholar
Ramaswamy, SD, Vigmostad, SC, Wahle, A, Lai, YG, Olszewski, ME, Braddy, KC, et al. Fluid dynamic analysis in a human left anterior descending coronary artery with arterial motion. Annals of Biomedical Engineering. 2004;32(12):16281641.Google Scholar
Frauenfelder, T, Boutsianis, E, Schertler, TL, Husmann, L, Leschka, S, Poulikakos, D, et al. In-vivo flow simulation in coronary arteries based on computed tomography datasets: Feasibility and initial results. European Radiology. 2007;17(5):12911300.Google Scholar
Johnson, DA, Naik, UP, Beris, AN. Efficient implementation of the proper outlet flow conditions in blood flow simulations through asymmetric arterial bifurcations. International Journal for Numerical Methods in Fluids. 2011;66(11):13831408.Google Scholar
Apostolidis, AJ, Beris, AN, Dhurjati, PS. Introducing CFD through a cardiovascular application in a fluid mechanics course. Chemical Engineering Education. 2014;48(3):175184.Google Scholar
Apostolidis, AJ, Moyer, AP, Beris, AN. Non-Newtonian effects in simulations of coronary arterial blood flow. Journal of Non-Newtonian Fluid Mechanics. 2016;233:155165.Google Scholar
Taylor, CA, Hughes, TJR, Zarins, CK. Finite element modeling of three-dimensional pulsatile flow in the abdominal aorta: Relevance to atherosclerosis. Annals of Biomedical Engineering. 1998;26(6):975987.Google Scholar
Gohil, TB, McGregor, RHP, Szczerba, D, Burckhardt, K, Muralidhar, K, Székely, G. Simulation of oscillatory flow in an aortic bifurcation using FVM and FEM: A comparative study of implementation strategies. International Journal for Numerical Methods in Fluids. 2011;66(8):10371067.Google Scholar
Moore, S, David, T, Chase, JG, Arnold, J, Fink, J. 3D models of blood flow in the cerebral vasculature. Journal of Biomechanics. 2006;39(8):14541463.Google Scholar
Alastruey, J, Parker, KH, Peiró, J, Byrd, SM, Sherwin, SJ. Modeling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. Journal of Biomechanics. 2007;40(8):17941805.Google Scholar
Alastruey, J, Moore, SM, Parker, KH, David, T, Peiró, J, Sherwin, SJ. Reduced modeling of blood flow in the cerebral circulation: Coupling 1-D, 0-D and cerebral autoregulation models. International Journal for Numerical Methods in Fluids. 2008;56(8):10611067.Google Scholar
Passerini, T, de Luca, MR, Formaggia, L, Quarteroni, A, Veneziani, A. A 3D/1D geometrical multiscale model of cerebral vasculature. Journal of Engineering Mathematics. 2009;64(4):319330.Google Scholar
Reymond, P, Perren, F, Lazeyras, F, Stergiopulos, N. Patient-specific mean pressure drop in the systemic arterial tree, a comparison between 1-D and 3-D models. Journal of Biomechanics. 2012;45(15):24992505.Google Scholar
Fahy, P, Delassus, P, McCarthy, P, Sultan, S, Hynes, N, Morris, L. An in vitro assessment of the cerebral hemodynamics through three patient specific circle of Willis geometries. Journal of Biomechanical Engineering -Transactions of the ASME. 2014;136(1):011007.Google Scholar
Spilker, RL, Feinstein, JA, Parker, DW, Reddy, VM, Taylor, CA. Morphometry-based impedance boundary conditions for patient-specific modeling of blood flow in pulmonary arteries. Annals of Biomedical Engineering. 2007;35(4):546559.Google Scholar
Campo-Deaño, L, Oliveira, MSN, Pinho, FT. A review of computational hematodynamics in middle celebral aneurysms and rheological models for blood flow. Applied Mechanics Reviews. 2015;67(3):030801–16.Google Scholar
Bessonov, N, Sequeira, A, Simakov, S, Vassilevskii, Yu, Volpert, V. Methods of blood flow modelling. Mathematical Modelling of Natural Phenomena. 2016;11(1):125.Google Scholar
Secomb, TW. Blood flow in the microcirculation. Annual Review of Fluid Mechanics. 2017;49(1):443461.Google Scholar
Malek, AM, Alper, SM, Izumo, S. Hemodynamic shear stress and its role in arteriosclerosis. Journal of the American Medical Association. 1999;282(21):20352042.Google Scholar
Cecchi, E, Giglioli, C, Valente, S, Lazzeri, C, Gensini, GF, Abbate, R, et al. Role of hemodynamic shear stress in cardiovascular disease. Atherosclerosis. 2011;214(2):249256.Google Scholar
Chaichana, T, Sun, ZH, Jewkes, J. Computational fluid dynamics analysis of the effect of plaques in the left coronary artery. Computational and Mathematical Methods in Medicine. 2012;(4i):504367.Google Scholar
Wentzel, JJ, Chatzizisis, YS, Gijsen, FJH, Giannoglou, GD, Feldman, CL, Stone, PH. Endothelial shear stress in the evolution of coronary atherosclerotic plaque and vascular remodelling: Current understanding and remaining questions. Cardiovascular Research. 2012;96(2):234243.Google Scholar
Topol, EJ, Califf, RM, Prystowsky, EN, Thomas, JD, Thompson, PD. Textbook of Cardiovascular Medicine. Philadelphia: Lippincott Williams & Wilkins; 2007; 283 p.Google Scholar
Pries, AR, Secomb, TW, Gaehtgens, P, Gross, JF. Blood flow in microvascular networks. Experiments and Simulation. Circulation Research. 1990;67(4):826834.Google Scholar
Turitto, VT. Blood viscosity, mass transport, and thrombogenesis. Progress in Hemostasis and Thrombosis. 1982;6:139177.Google Scholar
Olufsen, MS. Modeling flow and pressure in the systemic arteries. In Ottesen, JT, Olufsen, MS, Larsen, JK (eds.) Applied Mathematical Models in Human Physiology. Philadelphia: SIAM; 2004; pp. 91136.Google Scholar
Gijsen, FJH, Allanic, E, van de Vosse, FN, Janssen, JD. The influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90 degrees curved tube. Journal of Biomechanic. 1999;32(7):705713.Google Scholar
Lee, SW, Steinman, DA. On the relative importance of rheology for image-based CFD models of the carotid bifurcation. Journal of Biomechanical Engineering-Transactions ASME. 2008;129(2):273278.Google Scholar
Yilmaz, F, Gundogdu, MY. A critical review on blood flow in large arteries; relevance to blood rheology, viscosity models, and physiologic conditions. Korea-Australia Rheology Journal. 2008;20(4):197211.Google Scholar
Wang, SZ, Chen, JL, Ding, GH, Lu, G, Zhang, XL. Non-Newtonian computational hemodynamics in two patient-specific cerebral aneurysms with daughter saccules. Journal of Hydrodynamics. 2010;22(5):639646.Google Scholar
Seo, T. Numerical simulations of blood flow in arterial bifurcation models. Korea-Australia Rheology Journal. 2013;25(3):153161.Google Scholar
Apostolidis, AJ, Beris, AN. Modeling of the blood rheology in steady-state shear flows. Journal of Rheology. 2014;58(3):607633.Google Scholar
Bird, RB, Armstrong, RC, Hassager, O. Dynamics of Polymeric Fluids, vol. 1, 2nd ed. New York: Wiley-Interscience; 1987.Google Scholar
Owens, RG. A new microstructure-based constitutive model for human blood. Journal of Non-Newtonian Fluid Mechanics. 2006;140(1):5770.CrossRefGoogle Scholar
Bureau, M, Healy, JC, Bourgoin, D, Joly, M. Rheological properties of blood at low shear rate. Biorheology. 1980;17(1–2):191203.Google Scholar
Horner, JS, Armstrong, MJ, Wagner, NJ, Beris, AN. Investigation of blood rheology under steady and unidirectional large amplitude oscillatory shear. Journal of Rheology. 2018;62(2):577591.Google Scholar
Apostolidis, AJ, Armstrong, MJ, Beris, AN. Modeling of human blood rheology in transient shear flows. Journal of Rheology. 2015;59(1):275298.Google Scholar
Thurston, GB. Rheological parameters for the viscosity, viscoelasticity and thixotropy of blood. Biorheology. 1979;16(3):149162.Google Scholar
Quemada, D. A rheological model for studying the hematocrit dependence of red-cell red-cell and red-cell protein interactions in blood. Biorheology. 1981;18(3–6):501516.Google Scholar
Quemada, D. Blood rheology and its implication in flow of blood. In Rodkiewicz, CM (ed.) Int. Centre for Mechanical Sciences Courses and Lectures No 270. Wien: Springer-Verlag; 1983; pp. 1–127.Google Scholar
Quemada, D. A nonlinear Maxwell model of biofluids – Application to normal blood. Biorheology. 1993;30(3–4):253265.Google Scholar
Anand, M, Rajagopal, KR. A shear-thinning viscoelastic fluid model for describing the flow of blood. International Journal of Cardiovascular Medicine and Science. 2004;4(2):5968.Google Scholar
Fang, JN, Owens, RG. Numerical simulations of pulsatile blodd flow using a new constitutive model. Biorheology. 2006;43(5):637660.Google Scholar
Moyers-Gonzalez, M, Owens, RG. A non-homogeneous constitutive model for human blood. Part II. Asymptotic solution at large Péclet numbers. Journal of Non-Newtonian Fluid Mechanics. 2008;155(3):146160.Google Scholar
Moyers-Gonzalez, M, Owens, RG, Fang, J. A non-homogeneous constitutive model for human blood. Part 1. Model derivation and steady flow. Journal of Fluid Mechanics. 2008;617:324354.CrossRefGoogle Scholar
Moyers-Gonzalez, M, Owens, RG, Fang, J. A non-homogeneous constitutive model for human blood. Part III. Oscillatory flow. Journal of Non-Newtonian Fluid Mechanics. 2008;155(3):161173.Google Scholar
Moyers-Gonzalez, M, Owens, RG, Fang, J. On the high frequency oscillatory tube flow of healthy human blood. Journal of Non-Newtonian Fluid Mechanics. 2009;163(1–3):4561.Google Scholar
Anand, M, Kwack, J, Masud, A. A new generalized Oldroyd-B model for blood flow in complex geometries. International Journal of Engineering Science. 2013;72:7888.Google Scholar
Tsimouri, ICh, Stephanou, PS, Mavrantzas, VG. A constitutive rheological model for agglomerating blood derived from nonequilibrium thermodynamics. Physics of Fluids. 2018;30(3):030710.Google Scholar
Keener, J, Sneyd, J. Mathematical Physiology. New York: Springer; 1998.Google Scholar
Fedosov, DA, Caswell, B, Popel, AS, Karniadakis, GE. Blood flow and cell-free layer in microvessels. Microcirculation. 2010;17(8):615628.Google Scholar
Li, XJ, Peng, ZL, Lei, H, Dao, D, Karniadakis, GE. Probing red blood cell mechanics, rheology and dynamics with a two-component multi-scale model. Philosophical Transactions of the Royal Society A – Mathematics, Physics and Engineering Science. 2014;372:20130389.Google Scholar
Lipowsky, HH. Microvascular rheology and hemodynamics. Microcirculation. 2005;12(1):515.Google Scholar
Marcinkowska-Gapińska, A, Gapiński, J, Elikowski, W, Jaroszyk, F, Kubisz, L. Comparison of three rheological models of shear flow behavior studied on blood samples from post-infarction patients. Medical & Biological Engineering & Computation. 2007;45(9):837844.Google Scholar
Merrill, EW, Gilliland, ER, Cokelet, GC, Shin, H, Britten, A, Wells, RE. Rheology of blood and flow in the microcirculation. Journal of Applied Physiology. 1963;18(2):13.Google Scholar
Merrill, EW, Cheng, CS, Pelletier, GE. Yield stress of normal blood as a function of endogenous fibrinogen. Journal of Applied Physiology. 1969;26(1):13.Google Scholar
Merrill, EW. Rheology of blood. Physiological Reviews. 1969;49(4):863888.Google Scholar
Fåhræus, R. Influence of the rouleau formation of erythrocytes on the rheology of the blood. Acta Medica Scandinavica. 1958;161(2):151165.Google Scholar
Morris, CL, Rucknagel, DL, Shukla, R, Gruppo, RA, Smith, CM, Blackshear, P. Evaluation of the yield stress of normal blood as a function of fibrinogen concentration and hematocrit. Microvascular Research. 1989;37(3):323338.Google Scholar
Moreno, L, Calderas, F, Sanchez-Olivares, G, Medina-Torres, L, Sanchez-Solis, A, Manero, O. Effect of cholesterol and triglycerides levels on the rheological behavior of human blood. Korea-Australia Rheology Journal. 2015;27(1):110.Google Scholar
Apostolidis, AJ, Beris, AN. The effect of cholesterol and triglycerides on the steady state shear rheology of blood. Rheologica Acta. 2016;55(6):497509.Google Scholar
Asakura, S, Oosawa, F. On interaction between two bodies immersed in a solution of macromolecules. Journal of Chemical Physics. 1954;22(7):12551256.Google Scholar
Picart, C, Piau, JM, Galliard, H. Human blood shear yield stress and its hematocrit dependence. Journal of Rheology. 1998;42(2):112.Google Scholar
Morris, CL, Smith II, CM, Blackshear, PL. A new method for measuring the yield stress in thin layers of sedimenting blood. Biophysical Journal. 1987;52(2):229240.Google Scholar
Chien, S, Usami, S, Taylor, HM, Lundberg, JL, Gregersen, MI. Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. Journal of Applied Physiology. 1966;21(1):8187.Google Scholar
Zydney, AL, Oliver, JD, Colton, CK. A constitutive equation for the viscosity of stored red cell suspensions: Effect of hematocrit, shear rate, and suspending phase. Journal of Rheology. 1991;35(8):16391679.Google Scholar
Happel, J, Brenner, H. Low Reynolds Number Hydrodynamics. The Hague, the Netherlands: Martinus Nijhoff; 1983.Google Scholar
Merrill, EW, Benis, AM, Gilliland, ER, Sherwood, TK, Salzman, EW. Pressure-flow relations of human blood in hollow fibers at low flow rates. Journal of Applied Physiology. 1965;20(5):954967.Google Scholar
Chien, S, King, RG, Skalak, R, Usami, S, Copley, AL. Viscoelastic properties of human blood and red cell suspensions. Biorheology. 1975;12(6):341346.Google Scholar
Bureau, M, Healy, JC, Bourgoin, D, Joly, M. Etude rhéologique en régime transitoire de quelques échantillons de sangs humains artificiellement modifiés. Rheologica Acta. 1979;18(6):756768.Google Scholar
McMillan, DE, Strigberger, J, Utterback, NG. Rapidly recovered transient flow resistance: A newly discovered property of blood. American Journal of Physiology. 1987;253(4):H919–926.Google Scholar
Alves, MM, Rocha, C, Gonçalves, MP. Study of the rheological behavior of human blood using a controlled stress rheometer. Clinical Hemorheology and Microcirculation. 2013;53(4):369386.Google Scholar
Campo-Deaño, L, Dullens, RPA, Aarts, DGAL, Pinho, FT, Oliveira, MSN. Viscoelasticity of blood and viscoelastic blood analogues for use in polydimethylsiloxane in vitro models of the circulatory system. Biomicrofluidics. 2013;7(3):034102.Google Scholar
Sousa, PC, Carneiro, J, Vaz, R, Cerejo, A, Pinho, FT, Alves, MA, et al. Shear viscosity and nonlinear behavior of whole blood under large amplitude oscillatory shear. Biorheology. 2013;50(5–6):269282.Google Scholar
Johnson, MW, Segalman, D. A model for viscoelastic fluid behavior which allows non-affine deformation. Journal of Non-Newtonian Fluid Mechanics. 1977;2(3):255270.Google Scholar
White, JL, Metzner, AB. Development of constitutive equations for polymeric melts and solutions. Journal of Applied Polymer Science. 1963;7(5):18671889.Google Scholar
Souvaliotis, A, Beris, AN. An extended White–Metzner viscoelastic fluid model based on an internal structural parameter. Journal of Rheology. 1992;36(2):241271.Google Scholar
Beris, AN, Edwards, BJ. Thermodynamics of Flowing Systems with Internal Microstructure. New York: Oxford University Press; 1994.CrossRefGoogle Scholar
Anand, M, Rajagopal, KR. A short review of advances in the modelling of blood rheology and clot formation. Fluids. 2017;2(3):35.Google Scholar
Doraiswamy, D, Mujumdar, AN, Tsao, I, Beris, AN, Danforth, SC, Metzner, AB. The Cox-Merz rule extended: A rheological model for concentrated suspensions and other materials with a yield stress. Journal of Rheology. 1991;35(4):647685.Google Scholar
Clarion, M, Deegan, M, Helton, T, Hudgins, J, Monteferrante, N, Ousley, E, et al. Contemporary modeling and analysis of steady state and transient human blood rheology. Rheologica Acta. 2018:57(2):141168.Google Scholar
Sun, N, De Kée, D. Linear viscoelasticity and stress growth in blood. Canadian Journal of Chemical Engineering. 2002;80(3):495498.Google Scholar
Rajagopal, KR, Srinivasa, AR. Modeling anisotropic fluids within the framework of bodies with multiple natural configurations. Journal of Non-Newtonian Fluid Mechanics. 2001;99(2–3):109124.Google Scholar
Armstrong, MJ, Beris, AN, Rogers, SA, Wagner, NJ. Dynamic shear rheology of a thixotropic suspension: Comparison of an improved structure-based model with large amplitude oscillatory shear experiments. Journal of Rheology. 2016;60(3):433450.Google Scholar
Dimitriou, CJ, Ewoldt, RH, McKinley, GH. Describing and prescribing the Large Amplitude Oscillatory Shear Stress (LAOStress). Journal of Rheology. 2013;57(1):2770.Google Scholar
Merrill, EW, Pelletier, GA. Viscosity of human blood: Transition from Newtonian to non-Newtonian. Journal of Applied Physiology. 1967;23(2):178182.Google Scholar
Baskurt, OK, Boynard, M, Cokelet, GC, Connes, P, Cooke, BM, Forconi, S, et al. New guidelines for hemorheological laboratory techniques. Clinical Hemorheology and Microcirculation. 2009;42(2):7597.Google Scholar
Horner, JS, Beris, AN, Woulfe, DS, Wagner, NJ. Effects of ex vivo aging and storage temperature on blood viscosity. Clinical Hemorheology and Microcirculation. 2018;70(2):155172.Google Scholar
Mwasame, PM, Beris, AN, Diemer, RB, Wagner, NJ. A constitutive equation for thixotropic suspensions with yield stress by coarse-graining a population balance model. A.I.Ch.E. Journal. 2017;63(2):517531.Google Scholar
Beris, AN, Mavrantzas, VG. On the compatibility between various macroscopic formalisms for the concentration and flow of dilute polymer solutions. Journal of Rheology. 1994;38(5):12351250.Google Scholar
Öttinger, HC. Beyond Equilibrium Thermodynamics. Hoboken, NJ: Wiley-Interscience; 2005.Google Scholar
Germann, N, Cook, LP, Beris, AN. Nonequilibrium thermodynamic modeling of the structure and rheology of concentrated wormlike micellar solutions. Journal of Non-Newtonian Fluid Mechanics. 2013;196:5157.Google Scholar
Armstrong, MJ, Beris, AN, Wagner, NJ. An adaptive parallel tempering method for the dynamic data-driven parameter estimation of nonlinear models. A.I.Ch.E. Journal.2017;63(6):19371958.Google Scholar
Dintenfass, L. Blood rheology as diagnostic and predictive tool in cardiovascular diseases. Angiology. 1974;25(6):365372.Google Scholar
Jariwala, S, Horner, JS, Wagner, NJ, Beris, AN. Application of population balance-based thixotropic model to human blood. Journal of Non-Newtonian Fluid Mechanics. 2020;281:104294.Google Scholar

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×