Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-28T16:37:11.943Z Has data issue: false hasContentIssue false

Banding of the pulmonary trunk in preparation for a Fontan operation

Published online by Cambridge University Press:  19 August 2008

Takahiko Sakamoto
Affiliation:
Division of Cardiovascular Surgery and NaganoChildren’s Hospital, Nagano, Japan
Yorikazu Harada*
Affiliation:
Division of Cardiovascular Surgery and NaganoChildren’s Hospital, Nagano, Japan
Takamasa Takeuchi
Affiliation:
Division of Cardiovascular Surgery and NaganoChildren’s Hospital, Nagano, Japan
Katsumasa Morishima
Affiliation:
Division of Cardiovascular Surgery and NaganoChildren’s Hospital, Nagano, Japan
Gengi Satomi
Affiliation:
Division of Pediatric Cardiology, and NaganoChildren’s Hospital, Nagano, Japan
Satoshi Yasukochi
Affiliation:
Division of Pediatric Cardiology, and NaganoChildren’s Hospital, Nagano, Japan
Yoshinori Ohta
Affiliation:
Division of Cardiovascular Surgery and NaganoChildren’s Hospital, Nagano, Japan
*
Dr Yorikazu Harada MD, Division of Cardiovascular Surgery, Nagano Children’s Hospital, 3100, Toyoshina, Toyoshina-machi, Minamiazumi-gun, Nagano 399–82, Japan.. Tel: 81–263–73–6700; Fax: 81–263–73–5432

Abstract

Banding of the pulmonary trunk is an important surgical procedure for patients who have con genital cardiac malformations with unrestricted pulmonary flow. We propose a new concept for determining in such circumstances the most appropriate length of the band used to constrict the pulmonary trunk in preparation for a Fontan operation. We studied 14 patients undergoing banding of the pulmonary trunk and measured the following parameters: diameter of aorta, diameter of pulmonary trunk, length of pulmonary arterial band and maximum flow velocity across the banded segment. We calculated an index from our orig inal parameter based on the formula; length of band/(diameter of aorta diameter of pulmonary trunk). The diameter of aorta was 9.5 ± 1.4 mm, and that of the pulmonary trunk was 9.6 ± 2.3 mm. The length of the band was 16.5 ± 3.4 mm, giving a calculated index of 0.188 ± 0.038. The maximum flow velocity was 4.02 ± 0.46 m/s. No correlation was found between the length of the band and body weight, and also no correlation was found between the length of the band and maximum flow velocity. The calculated index had a negative correlation with the maximum velocity of flow across the band (y = -8.13x + 5.56, R = 0.74, p < 0.01). We believe that the proposed index is a useful guide in determining the length of a pulmonary band when preparing patients for a Fontan operation.

Type
Original Articles
Copyright
Copyright © Cambridge University Press 1999

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Albus, RA, Colonel, L, Trusler, GA, Izukawa, T, Williams, WG. Pulmonary artery banding. J Thorac Cardiovasc Surg 1984; 88: 645653.Google Scholar
2.Trusler, GA, Mustard, WT. A method of banding the pul monary artery for large isolated ventricular septal defect with and without transposition of great arteries. Ann Thorac Surg 1972; 13:351355.Google Scholar
3.Satomi, G: Atlas of Pediatric and Fetal Echocardiography, Vector Core, Tokyo, 1991.Google Scholar
4.Muraoka, R, Yokota, M. Aoshima, M, Nomoto, S, Kyoku, I, Kobayashi, A, Nakano, H, Ueda, K, Saito, A. Extrathoracically adjustable pulmonary artery banding. J Thorac Cardiovasc Surg 1983; 86: 582586.CrossRefGoogle ScholarPubMed
5.Dajee, H, Benson, L, Laks, H. An improved method of pul monary artery banding. Ann Thorac Surg 1984; 37: 254257.CrossRefGoogle Scholar
6.Solis, E, Heck, CF, Seward, JB, Kaye, MPPercutaneously adjustable pulmonary artery band. Ann Thorac Surg 1986; 41: 6569.CrossRefGoogle ScholarPubMed
7.Higashidate, M, Beppu, T, Imai, Y, Kurosawa, H. Percutaneously adjustable pulmonary artery band. An experimental study. J Thorac Cardiovasc Surg 1989; 97: 864869.CrossRefGoogle ScholarPubMed
8.Warren, ET, Heath, BJ, Brand, WW. A staged expanding pul monary artery band. Ann Thorac Surg 1992; 54: 240243.CrossRefGoogle Scholar
9.Vince, DJ, Culham, JAG, LeBlanc, JG, Taylor, GP. A dilatable prosthesis for banding the pulmonary artery: Initial clinical experience. J Thorac Cardiovasc Surg 1992; 103: 392393.CrossRefGoogle ScholarPubMed
10.Watanabe, H, Miyamura, H, Sugawara, M, Takahashi, Y, Tatebe, S, Shinonaga, M, Takahashi, M, Eguchi, S, Sato, I. A new opera tive technique for pulmonary artery banding: adjustment of pulmonary artery bands by mitral valve flow velocity. Kyoubu-Geka 1994; 47: 869875.Google Scholar
11.Freedom, RM, Benson, L, Smallhorn, JF, Williams, WG, Trusler, GA, Rowe, RD. Subaortic stenosis, the univentricular heart, and banding of the pulmonary artery: an analysis of the courses of 43 patients with univentricular heart palliated by pulmonary artery banding. Circulation 1986; 73: 758764.CrossRefGoogle ScholarPubMed
12.Malcic, I, Sauer, U, Stern, H, Kellerer, M, Kuhlein, B, Locher, D, Buhlmeyer, K, Sebening, F. The Influence of pulmonary artery banding on outcome after the Fontan operation. J Thorac Cardiovasc Surg 1992; 104: 743747.CrossRefGoogle ScholarPubMed
13.Saito, S, Imai, Y, Takanashi, Y, Aoki, M, Hoshino, S, Nakata, S, Terada, M, Shinozaki, M. Fontan procedure after pulmonary artery banding — surgical results and new anatomical repair for tricuspid atresia. J Jpn Assn Thorac Surg 1995; 43: 16311638.Google ScholarPubMed