Hostname: page-component-cd9895bd7-8ctnn Total loading time: 0 Render date: 2024-12-28T03:40:15.696Z Has data issue: false hasContentIssue false

Oesophageal perforation in a neonate during transoesophageal echocardiography for cardiac surgery

Published online by Cambridge University Press:  09 September 2014

Jeffrey W. Miller*
Affiliation:
Department of Anesthesiology, Cincinnati Children’s Hospital, Cincinnati, OhioUnited States of America
Catherine K. Hart
Affiliation:
Department of Otolaryngology, Cincinnati Children’s Hospital, Cincinnati, OhioUnited States of America
Christopher J. Statile
Affiliation:
Department of Cardiology, Cincinnati Children’s Hospital, Cincinnati, Ohio, United States of America
*
Correspondence to: J. W. Miller, Department of Anesthesiology, Division of Cardiac Anesthesia, Cincinnati Children’s Hospital, 3333 Burnet Avenue, Cincinnati, Ohio 45229, United States of America. Tel: 513 636 9234; Fax: 513 636 7337; E-mail: Jeff.Miller@cchmc.org

Abstract

Oesophageal perforation is a rarely reported complication of transoesophageal echocardiography in infants. This case involves a 3.1-kg neonate with Trisomy 21, atrioventricular septal defect, and hypoplastic aortic arch undergoing aortic arch advancement and pulmonary artery banding. A paediatric transoesophageal echocardiography probe was placed intraoperatively causing a contained false passage from the oesophagus below the cricopharyngeus muscle with extension into the left posterior mediastinum. The perforation healed within 2 weeks without permanent sequelae after conservative medical management.

Type
Brief Reports
Copyright
© Cambridge University Press 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Stevenson, JG. Incidence of complications in pediatric transesophageal echocardiography: experience in 1650 cases. J Am Soc Echocardiogr 1999; 12: 527532.CrossRefGoogle ScholarPubMed
2. Hilberath, JN, Oakes, DA, Shernan, SK, Bulwer, BE, D’Ambra, MN, Eltzschig, HK. Safety of transesophageal echocardiography. J Am Soc Echocardiogr 2010; 23: 11151127; quiz 1220-1221.CrossRefGoogle ScholarPubMed
3. Philips_Healthcare. TEE Transducer Care, 2012. Retrieved March 2014, from http://www.philips.com/ultrasound Google Scholar
4. Knight, RB, Webb, DE, Coppola, PC. Pharyngeal perforation masquerading as esophageal atresia. J Pediatr Surg 2009; 44: 22162218.CrossRefGoogle ScholarPubMed
5. Muhiudeen-Russell, IA, Miller-Hance, WC, Silverman, NH. Unrecognized esophageal perforation in a neonate during transesophageal echocardiography. J Am Soc Echocardiogr 2001; 14: 747749.CrossRefGoogle Scholar
6. Sasaki, T, Culham, G, Gandhi, SK. Conservative management of iatrogenic esophageal perforation during neonatal cardiac surgery. World J Pediatr Congenit Heart Surg 2012; 3: 528530.CrossRefGoogle ScholarPubMed
7. Wellen, SL, Glatz, AC, Gaynor, JW, Montenegro, LM, Cohen, MS. Transesophageal echocardiography probe insertion failure in infants undergoing cardiac surgery. Congenit Heart Dis 2013; 8: 240245.CrossRefGoogle ScholarPubMed
8. Gander, JW, Berdon, WE, Cowles, RA. Iatrogenic esophageal perforation in children. Pediatr Surg Int 2009; 25: 395401.CrossRefGoogle ScholarPubMed
9. Greene, MA, Alexander, JA, Knauf, DG, et al. Endoscopic evaluation of the esophagus in infants and children immediately following intraoperative use of transesophageal echocardiography. Chest 1999; 116: 12471250.CrossRefGoogle ScholarPubMed