Abstract
CHDs affecting the right ventricular outflow tract often require repeated surgical or transcatheter interventions due to pulmonary insufficiency or stenosis. This study presents percutaneous implantation of large self-expanding valves in patients with complex right ventricular outflow tract anatomy after prior pulmonary branch stenting.
- Type
- Brief Report
- Information
- Copyright
- © The Author(s), 2025. Published by Cambridge University Press
References
Fiszer, R, Dryżek, P, Szkutnik, M et al. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation. Cardiol J 2017; 24: 604–611.CrossRefGoogle ScholarPubMed
Promphan, W, Prachasilchai, P, Siripornpitak, S, Qureshi, SA, Layangool, T. Percutaneous pulmonary valve implantation with the Venus P-valve: clinical experience and early results. Cardiol Young 2016; 26: 698–710.CrossRefGoogle ScholarPubMed
Husain, J, Praichasilchai, P, Gilbert, Y, Qureshi, SA, Morgan, GJ. Early European experience with the Venus P-valve®: filling the gap in percutaneous pulmonary valve implantation. EuroIntervention 2016; 12: e643–e651.CrossRefGoogle Scholar
Garay, F, Pan, X, Zhang, YJ, Wang, C, Springmuller, D. Early experience with the Venus p-valve for percutaneous pulmonary valve implantation in native outflow tract. -valve for percutaneous pulmonary valve implantation in native outflow tract. Neth Heart J 2017; 25: 76–81.CrossRefGoogle ScholarPubMed
Morgan, GJ, Sivakumar, K, Promphan, W, Goreczny, S, Prachasilchai, P, Qureshi, S. Early clinical experience with the straight design of Venus P-valveTM in dysfunctional right ventricular outflow tracts. Catheter Cardiovasc Interv 2020; 96: E653–E659.CrossRefGoogle Scholar
Morgan, G, Prachasilchai, P, Promphan, W et al. Medium-term results of percutaneous pulmonary valve implantation using the Venus P-valve: international experience. EuroIntervention 2019; 14: 1363–1370.CrossRefGoogle ScholarPubMed
Sivakumar, K, Sagar, P, Qureshi, S et al. Outcomes of Venus P-valve for dysfunctional right ventricular outflow tracts from Indian Venus P-valve database. Ann Pediatr Cardiol 2021; 14: 281–292.CrossRefGoogle ScholarPubMed
Góreczny, S, Szeliga, J, Lazu, M, Załuska-Pitak, B, Gewillig, M. First Polish pediatric experience with percutaneous self-expandable pulmonary valve implantation. Kardiol Pol 2024; 82: 101–102.CrossRefGoogle ScholarPubMed
Góreczny, S, Szeliga, J, Lazu, M, Becht, R, Mroczek, T, Qureshi, S. Implantation of a large self-expanding pulmonary valve using the jugular vein approach in a teenage patient. Kardiol Pol 2024; 82: 549–550.CrossRefGoogle Scholar
Goreczny, S, Moszura, T, Dryzek, P et al. Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 2017; 25: 91–99.CrossRefGoogle Scholar