Published online by Cambridge University Press: 23 April 2021
Congenital heart block is a rare and lethal condition in paediatric population associated with maternal connective tissue disorders and rarely with structural cardiac disease like atrioventricular canal defects with or without left isomerism and congenitally corrected transposition of great arteries. Pacing in neonate if indicated is generally accomplished by epicardial pacing systems. However, in cases of significant bradycardia and haemodynamic instability, temporary pacemaker implantation via transvenous approach remains as a suitable option. Despite the advances in percutaneous catheter interventions, use of transvenous pacing in newborn is extremely challenging due to inadvertent risk of vessel injury, thrombus formation and mortality, and most of the time technical inability to place the lead within the right ventricular cavity. We report a case of congenital complete atrioventricular block in a premature male with birth weight of 1.51 kg who was managed with temporary pacemaker implantation through umbilical vein.