Hostname: page-component-78c5997874-ndw9j Total loading time: 0 Render date: 2024-11-10T11:44:59.073Z Has data issue: false hasContentIssue false

Transcatheter closure of a patent arterial duct with the Amplatzer duct occluder in the area of a large thoracic aortic aneurysm

Published online by Cambridge University Press:  01 April 2009

Payam Ghazi
Affiliation:
Research Unit, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
Ali-Mohammad Haji-Zeinali*
Affiliation:
Department of Interventional Cardiology, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
*
Correspondence to: Ali-Mohammad Haji-Zeinali, MD, Assistant Professor of Interventional Cardiology, Department of Interventional Cardiology, North Kargar and Jalal-Al-Ahmad Cross, Tehran Heart Center, Tehran 1411713138, Iran. Tel: +98 21 88029721; Fax: +98-21-88029702; Cell: +98 912 1301430; E-mail: ali_zeinali_cardio@yahoo.com

Abstract

We describe successful closure of a persistently patent arterial duct, using an Amplatzer occluder, in the presence of a large thoracic aortic aneurysm in the area of the ductal ampulla. Although percutaneous closure is more difficult in this setting, because of the risk of traumatising the fragile tissues, it can safely be performed. In our case, it produced a decrease in the size of the aneurysm, and permitted us to delay endovascular repair of the thoracic aorta.

Type
Brief Report
Copyright
Copyright © Cambridge University Press 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Al-Ata, J, Arfi, AM, Hussain, A, Kouatli, AA, Jalal, MO. The efficacy and safety of the Amplatzer duct occluder in young children and infants. Cardiol Young 2005; 15: 279285.CrossRefGoogle ScholarPubMed
2.Butera, G, De Rosa, G, Chessa, M, et al. Transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder in very young symptomatic children. Heart (British Cardiac Society) 2004; 90: 14671470.Google Scholar
3.Vijayalakshmi, IB, Chitra, N, Rajasri, R, Vasudevan, K. Initial clinical experience in transcatheter closure of large patent arterial ducts in infants using the modified and angled Amplatzer duct occluder. Cardiol Young 2006; 16: 378384.CrossRefGoogle Scholar
4.Wang, JK, Wu, MH, Hwang, JJ, Chiang, FT, Lin, MT, Lue, HC. Transcatheter closure of moderate to large patent ductus arteriosus with the Amplatzer duct occluder. Catheter Cardiovasc Interv 2007; 69: 572578.CrossRefGoogle ScholarPubMed
5.Marwah, A, Radhakrishnan, S, Shrivastava, S. Immediate and early results of closure of moderate to large patent arterial ductus using the new Amplatzer device. Cardiol Young 2000; 10: 208211.CrossRefGoogle ScholarPubMed
6.Thanopoulos, BD, Hakim, FA, Hiari, A, et al. Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder. J Am Coll Cardiol 2000; 35: 10161021.Google Scholar
7.Pass, RH, Hijazi, Z, Hsu, DT, Lewis, V, Hellenbrand, WE. Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results. J Am Coll Cardiol 2004; 44: 513519.CrossRefGoogle ScholarPubMed
8.Masura, J, Tittel, P, Gavora, P, Podnar, T. Long-term outcome of transcatheter patent ductus arteriosus closure using Amplatzer duct occluders. Am Heart J 2006; 151: 755.e7755.e10.Google Scholar
9.Rosen, RJ, Green, RM. Endoleak management following endovascular aneurysm repair. J Vasc Interv Radiol 2008; 19: S3743.CrossRefGoogle ScholarPubMed
10.Preventza, O, Wheatley, GH 3rd, Ramaiah, VG, et al. Management of endoleaks associated with endovascular treatment of descending thoracic aortic diseases. J Vasc Surg 2008; 48: 6973.CrossRefGoogle ScholarPubMed