Published online by Cambridge University Press: 05 April 2021
Children with CHD carry an additional burden of pulmonary insufficiency, often necessitating prolonged ventilatory support, especially in the peri-operative phase. There has been an increase in the utilisation of non-invasive ventilatory support for these children. The objective of this study was to evaluate the utilisation, safety, and outcomes of RAM cannula as a tool for escalation and de-escalation of respiratory support in paediatric cardiac patients less than one year of age.
A single-centre retrospective cohort study of patients supported with RAM cannula.
A total of 275 instances of RAM use were included in the study, 81.1% being post-operative. Patients were stratified into escalation and de-escalation cohorts based on the indication of non-invasive ventilation. The success rate of using RAM cannula was 69.5% overall, 66.1% in the escalation group, and 72.8% in the de-escalation group. At baseline, age at cardiac ICU admission >30 days, FiO2 ≤ 40%, PaCO2 ≤ 50 mmHg; and after 12 hours of non-invasive ventilation support respiratory rate ≤ 60/min, PaO2 ≥ 50 mmHg, PaCO2 ≤ 50 mmHg; and absence of worsening on follow-up chest X-ray predicted the success with a sensitivity of 95% in the logistic regression model. Successful support was associated with a significantly shorter unit stay.
RAM cannula can be safely used to provide non-invasive support to infants in the cardiac ICU for escalation and de-escalation of respiratory support. Factors associated with success can be used to make decisions about candidacy and appropriate timing of non-invasive ventilation use to maximise effectiveness.